  1. Replies
    17
    Views
    1,119

    so , after saying all that (I have no life) , the...

    so , after saying all that (I have no life) , the RC RH conversation is as others posted , for when there are two separate control transformers involved with the heating/cooling system , removing...
  2. Replies
    17
    Views
    1,119

    maybe add to confusion , all the contactors and...

    maybe add to confusion , all the contactors and relays that control the end devices like burners , fans etc , are loads that the thermostat controls , each of those loads have one of their two...
  3. If that PVC is going to a pool filter this might...

    If that PVC is going to a pool filter this might have been part of the cause , hmmm HTH and acid from the flue gas makes chlorine gas? ohhhhh Myyyyyyyy!
  4. Replies
    18
    Views
    1,386

    good? those look Great!

    good? those look Great!
  5. My mistake , misread your tank temp as 185 , like...

    My mistake , misread your tank temp as 185 , like other poster , 100 may be too warm , but confirm , 150 is definitely too warm too! This system has worked fine for two years Right? check controller...
  6. This is my best guess, Right now your...

    This is my best guess, Right now your expirienceing colder than usual outdoor temperatures? , your reset controller has ramped up the buffer tank temperature to compensate and the upper limit was set...
  7. Replies
    17
    Views
    894

    is the machine leaning back a little?

    is the machine leaning back a little?
  8. Replies
    10
    Views
    944

    Thats ok , all those DPBP valves will help , this...

    Thats ok , all those DPBP valves will help , this looks really expensive!How many loops on each pump circuit?
  9. Replies
    24
    Views
    1,270

    This does make sense , while the compressors out...

    This does make sense , while the compressors out it is easier too!
  10. Replies
    23
    Views
    1,332

    Thanks for following up:cheers:

    Thanks for following up:cheers:
  11. Replies
    6
    Views
    448

    well , for starters I would suggest you get a...

    well , for starters I would suggest you get a simple Manual J load calc form and plug in the basic numbers so you have better than a guess, your ideas on the design seem reasonable , but best to err...
  12. Replies
    2
    Views
    185

    Well hello , this is a good place for that and...

    Well hello , this is a good place for that and more , any specific questions? getting Ducks in a row? ;-)
  13. Here is another thought , I have seen a new...

    Here is another thought , I have seen a new install where the indoor coil must have been dropped during shipping or whatever , and all the lower return bends were flattened on the back (couldn't see...
  14. lots of good advice here , sounds like a bear to...

    lots of good advice here , sounds like a bear to anylyze it all! I for one admire the tenacity for this service call you are showing , sounds like a real learning expirience, clear your head , take...
  15. Replies
    24
    Views
    1,270

    To confirm it isn't the Reversing valve ,...

    To confirm it isn't the Reversing valve , consider this , If the pressures are the same because the gas is "short circuiting" thru the valve, the compressor would be pumping thoroughly superheated...
  16. Replies
    24
    Views
    1,270

    After going thru many slides on the internals of...

    After going thru many slides on the internals of Reversing valves I found that some manufacturers control the pilot valve between discharge and slide , and others between suction side and slide ,...
  17. Replies
    18
    Views
    1,061

    The bleed port in the accumulator plugged?...

    The bleed port in the accumulator plugged? filling with Refrigerant and oil and periodically "overflowing"?
  18. Replies
    23
    Views
    1,332

    Think we will ever hear what he found?

    Think we will ever hear what he found?
  19. Replies
    1
    Views
    168

    Hey Dave , JARTS or BCIT?

    Hey Dave , JARTS or BCIT?
  20. Replies
    9
    Views
    2,407

    That horse just doesn't look right..............

    That horse just doesn't look right..............
  21. Replies
    16
    Views
    3,792

    guess they didn't have a "J".......

    guess they didn't have a "J".......
  22. Replies
    7
    Views
    2,068

    Wow .......I mean where do you start? No gas...

    Wow .......I mean where do you start? No gas inspectors around?
  23. That was all to keep you too busy to spot his...

    That was all to keep you too busy to spot his grow show....
  24. Replies
    23
    Views
    982

    Sounds familiar , have had lots of fun with...

    Sounds familiar , have had lots of fun with Infinity systems not picking up the equipment correctly on startup. as I recall ensuring the power is on for 5 minutes before doing the software "install"...
  25. Replies
    6
    Views
    613

    sounds like a question for your wholsaler , and...

    sounds like a question for your wholsaler , and take pictures to avoid communication problems :-)