    If you look at the compressor inside the O .D....

    If you look at the compressor inside the O .D. unit while it's running, there should only be about a one inch ring of sweat where the suction (larger) line connects to the compressor. If there's much...
  2. Replies
    4
    Views
    357

    Does your thermostat have a "CIRC" setting for...

    Does your thermostat have a "CIRC" setting for the fan? If so, this setting will circulate air for about every 12 minutes out of 30.

    If it's shorter 1-3 minute bursts of air, it may be there's a...
  3. Replies
    31
    Views
    1,266

    They're giving you bad info about the line sets...

    They're giving you bad info about the line sets having to be that long. As someone already pointed out, they have to be a MINIMUM of 10 feet. There's also a maximum length per line set and a total...
  4. Replies
    5
    Views
    408

    An air conditioning system needs to move about...

    An air conditioning system needs to move about 400 cfm per ton. If you have a 4 ton unit that's 1600 cfm. Your bedroom may only need and have ducting to carry 300cfm. The IQ drive can modulate down...
  5. Replies
    5
    Views
    408

    Poor reviews are usually due to the misconception...

    Poor reviews are usually due to the misconception that when something goes wrong the appliance is to be blamed. In reality, 98% of the time, the installer is the one who should be blamed - especially...
  6. Replies
    10
    Views
    588

    Look at your chimney outlet with the boiler...

    Look at your chimney outlet with the boiler firing and hot. See any steam?

    Is there any hidden piping that's not visible?
  7. "We have a 3100 sf cape house in Boston, MA and...

    "We have a 3100 sf cape house in Boston, MA and are planning a partial 2nd story remodel (raising roof, etc.), with new HVAC for the remodel. Our current systems include whole house central air,...
  8. No, Absolutely Not!

    Not only will a heat pump water heater not give you enough btu's, but it won't give you hot enough water for the AHUs unless their coils are way over-sized and the blower speed is drastically lowered...
  9. Replies
    6
    Views
    333

    Not a good idea, using a timer. Unless that's...

    Not a good idea, using a timer.

    Unless that's a condensing boiler by design, it will become one if you do what you're proposing.

    What the tenants are doing doesn't make sense. Between what...
  10. Replies
    35
    Views
    1,680

    That boiler is made by Utica. I'd call their tech...

    That boiler is made by Utica. I'd call their tech support. 315-731-4163 Todd's direct line.

    You might also look for some debris "flapping" around in the gas line. Also keep your manometer on the...
  11. Replies
    35
    Views
    1,680

    Those numbers don't add up, but you have too...

    Those numbers don't add up, but you have too little fuel pressure. That has to be set correctly before combustion readings are taken.
    Site rules don't allow technical advice to be given out in this...
  12. Replies
    35
    Views
    1,680

    What were your O2, CO2 and CO readings?

    What were your O2, CO2 and CO readings?
  13. Replies
    35
    Views
    1,680

    Combustion analyzer? Do you have a digital...

    Combustion analyzer?

    Do you have a digital combustion analyzer?
  14. Two gauges reading 25+ and one relief valve...

    Two gauges reading 25+ and one relief valve dumping. I'd say the odds are in favor of these three components being accurate.

    How the system is piped and pumped can also effect the pressure in each...
  15. Replies
    10
    Views
    944

    I can't see why you would need five different...

    I can't see why you would need five different temps unless there are five different types of emitters.

    Do you know the heat loss of the house and the output of the boilers?
  16. Replies
    10
    Views
    944

    I think that distributor designed it primarily...

    I think that distributor designed it primarily for how many components he could sell.

    A little hydronic math:
    A 1/2" pipe will carry 1.5 gpm
    A 3/4" pipe wil carry 4 gpm
    A 1" pipe will carry 8...
  17. Replies
    10
    Views
    944

    I think you may be slightly over-pumped.

    I think you may be slightly over-pumped.
  18. I've got one who keeps sending the wrong...

    I've got one who keeps sending the wrong fittings. It really stinks when your 50 miles away in the middle of nowhere and you open a box and several are the wrong size.

    I rewarded his diligence by...
  19. Thread: Slum Lord

    by bobboan
    Replies
    30
    Views
    3,089

    Marc, You stated in your photo description:...

    Marc,
    You stated in your photo description: "rotted fancy gas valve from water drizzling on it". Now you're saying it's condensation. Which is it? The gas valve appears to be below the leak that you...
  20. Thread: Slum Lord

    by bobboan
    Replies
    30
    Views
    3,089

    It IS unsafe! A water damaged gas valve can stick...

    It IS unsafe! A water damaged gas valve can stick open and you'll have a run away boiler. Guess who will be held responsible if it explodes? Not the landlord, but YOU! You are the professional! You...
  21. Replies
    3
    Views
    420

    No, you can't get any proprietary parts in the...

    No, you can't get any proprietary parts in the U.S. However, things like the ignition module, gas valve, aquastat, etc. are standard Honeywell parts.

    As far as quality goes, it's a very good...
  22. Your pressure is definitely too low. It should be...

    Your pressure is definitely too low. It should be 12psi cold for a one story bldg, 15 psi for two story, 18 psi for a three. That's conservative.

    We would need a diagram with pipe sizes, lengths...
  23. My point was that in order for scaling to be an...

    My point was that in order for scaling to be an issue fresh water would have to be introduced for an extended period. In order for that to happen, you would have to be leaking somewhere.

    There may...
  24. Whistling is usually caused by the flow velocity...

    Whistling is usually caused by the flow velocity being above 4 ft. per sec. It could be that scaling has reduced the internal diameter of the piping enough, but if that's the case, you have other...
  25. Replies
    5
    Views
    382

    You need to get you installing contractor back...

    You need to get you installing contractor back out and insist that he correct the problem. Site rules prohibit us from giving DIY advice, but it sounds like an ignition problem. Did your installer...