  1. Thread: Carrier CCN ?

    by Balibe
    Replies
    5
    Views
    126

    I-Vu can change the address of CCN Controllers....

    I-Vu can change the address of CCN Controllers. It's under Setup, at the top where you scan in new devices.
  2. Replies
    6
    Views
    185

    Everything looks good, did you enabled the Local...

    Everything looks good, did you enabled the Local Device?
  3. Replies
    5
    Views
    258

    The NAM was used to connect a Modem or Computer...

    The NAM was used to connect a Modem or Computer to the network before TelLinks came out.

    The NAM were originally used with Gen2 VVT systems to connect to the comm bus locally or remotely with the...
  4. Replies
    5
    Views
    258

    Is it an old system? You may have an NAM (Network...

    Is it an old system? You may have an NAM (Network Access Module). These have an address (1 to 63) and are on the network. It should show only the Controller ID table with the software. These were...
  5. Replies
    2
    Views
    196

    You can only use ApplicationBuilder to generate...

    You can only use ApplicationBuilder to generate the program, SNAP or Eikon programs are not supported with i-Vu CCN 4.0/4.2. The ApplicationBuilder programs are to be associated with Comfort...
  6. Replies
    20
    Views
    1,154

    Attached is a screenshot of one I did. It uses...

    Attached is a screenshot of one I did. It uses the sun position and has been working well. It does not rely on internet as the sun position is a constant once the longitude/lattitude is entered.
    ...
  7. Replies
    15
    Views
    820

    ComfortView 2.0 is designed to run on Windows...

    ComfortView 2.0 is designed to run on Windows 98/Me
    ComfortView 3.0/3.1/3.2 is designed to run on Windows XP Professional
    Network Service Tool V is designed to run on Windows XP/Vista/7
  8. Replies
    15
    Views
    820

    You can, each location can be individual with the...

    You can, each location can be individual with the Ethernet setup as a gateway. They can also be connected together with one as the gateway and the remaining as bridges.

    Have you verified the ports...
  9. Replies
    7
    Views
    750

    With a CONNECT you do not need the bus/element as...

    With a CONNECT you do not need the bus/element as you are in the same controller. A NETWORK POINT would require the bus/element as the program need to go to another controller.

    If you paste the...
  10. Replies
    7
    Views
    750

    A UC16 is beige, a CC1600 is white. The UC16 is...

    A UC16 is beige, a CC1600 is white. The UC16 is an entry level controller with a set of built-in algorithms to perform tasks with 8ins/8outs, it will not hold any BEST++. The CC1600 is a higher...
  11. Replies
    7
    Views
    750

    Are you working with a Universal Controller...

    Are you working with a Universal Controller [UC16] or a Comfort Controller [CC1600]. There is a difference as you can't use BEST++ on a UC16.
  12. Thread: Carrier I-VU

    by Balibe
    Replies
    8
    Views
    970

    What are the alarms you are getting? There are...

    What are the alarms you are getting? There are no default alarms setup in i-Vu other that communications for a CC6400, all other alarms need to be setup and programmed in the CC6400.

    As...
  13. Replies
    22
    Views
    1,799

    Not everyone is off topic, at least two people...

    Not everyone is off topic, at least two people requested the model number and you have not provided. Without the model number it is hard for us to know what system/setup you have.

    People have...
  14. Replies
    9
    Views
    746

    They are Orion Controls by Wattmaster ..... ...

    They are Orion Controls by Wattmaster .....

    http://www.orioncontrols.com/
  15. Replies
    12
    Views
    892

    3V is CCN, not Open. 3V is 100% compatible with...

    3V is CCN, not Open. 3V is 100% compatible with i-Vu v4.0 CCN, v4.2 CCN, v4.2 CCN Plus and v4.2 CCN Pro. It is not compatible with i-Vu Open v5.0



    Disregard these specs, this is for i-Vu Open...
  16. Thread: AX CCN Driver

    by Balibe
    Replies
    12
    Views
    774

    The System Pilot is to access the system, will...

    The System Pilot is to access the system, will work like NST but easier with software.

    There is no supervisory controller in a 3V System. The devices are setup to talk to each other and the Air...
  17. Replies
    7
    Views
    614

    What is the software version of the pilot? The...

    What is the software version of the pilot? The current version is v2.0, may need to update the pilot.

    Not sure the revision fixes as they started with v1.0, then v1.1, v1.2 and now v2.0. Before...
  18. Thread: JCI FX BacNet

    by Balibe
    Replies
    3
    Views
    571

    Make sure you select the correct controller from...

    Make sure you select the correct controller from the New Application Screen. Each one has two. One is for N2/Lon and the other is for BacNet. If you start programming on the wrong one you can't...
  19. Replies
    8
    Views
    940

    The software can only be licensed to one computer...

    The software can only be licensed to one computer at a time, done thru Trane's website and uses the computer to generate the locking code. If the software you have has already been...
  20. Replies
    6
    Views
    458

    I am not a McQuay expert, have you looked at this...

    I am not a McQuay expert, have you looked at this PDF? -= LINK =-

    If this is not your unit, search mcquay.com as they are fairly good with literature on their products. You may also need to...
  21. Replies
    26
    Views
    3,517

    The LP-KIT204 is just a MS/TP to IP router made...

    The LP-KIT204 is just a MS/TP to IP router made by Contemporary Controls, it will see any MS/TP device on the network. Works with FX/PCG/FEC, you will need the device software to upload/download...
  22. Replies
    6
    Views
    458

    I have done a chiller with Microtech III to a...

    I have done a chiller with Microtech III to a Johnson FX-60 with no issues but one. What points are not holding? I am assuming the setpoints. On the chiller I had, after a power reset the chiller...
  23. Replies
    15
    Views
    1,313

    +1

    +1
  24. Replies
    2
    Views
    414

    The UC16 is a canned controller. Cannot add...

    The UC16 is a canned controller. Cannot add algo's, occpc's or setpt's, Best++, etc to the device. You are limited to the 4 setpt's and with their unit of measure, but you can change the unit of...
  25. Replies
    5
    Views
    554

    Heard of it, never seen it. AFAIK it is what...

    Heard of it, never seen it. AFAIK it is what Carrier uses for drawings [like AutoCad], have seen the name on control drawings from Carrier.