  1. Replies
    4
    Views
    866

    Reading amps

    Sorry for the rookie question, but I have never been able to get a straight answer.

    Went to a no heat call tonight. Thermostat was turned off but blower was still running, I take off panels and...
  2. Replies
    7
    Views
    1,660

    I particularly like the needless use of 90’s in...

    I particularly like the needless use of 90’s in the liquid line.
  3. Replies
    40
    Views
    6,817

    All that, and i'll bet all the customer needed...

    All that, and i'll bet all the customer needed was a run cap. hahaha
  4. Replies
    15
    Views
    1,430

    Wheel appeared fine. Straight. No vibration.

    Wheel appeared fine. Straight. No vibration.
  5. Replies
    15
    Views
    1,430

    Yes. It is a GCS16. Sorry, typo. Anyhow yes...

    Yes. It is a GCS16. Sorry, typo. Anyhow yes the nameplate calls for a 3/4 hp motor. I removed a Century 3/4 hp 1075 3 speed motor rated for 4 amps. I don't know what was in it before that.
  6. Replies
    15
    Views
    1,430

    Blower Motor Failures

    No cool call at a hair salon. Failure was the blower motor. Unit is a Lennox GCS18-060-75-4Y. Customer stated that she has been at this location for 3 years and has had to replace this motor every...
  7. Replies
    11
    Views
    3,116

    That dip in the condensate line serves as the...

    That dip in the condensate line serves as the trap.
  8. Replies
    26
    Views
    3,625

    Yup!

    Yup!
  9. Replies
    26
    Views
    3,625

    New way to save 1000's on your power bill!

    I took this picture while standing on a busy sidewalk! It must be safe though, green wire is only a ground right? pfft...
  10. Replies
    17
    Views
    3,483

    It may not have been internally insulated, but it...

    It may not have been internally insulated, but it is now.
  11. Replies
    7
    Views
    1,661

    That was the norm here for several years, 2...

    That was the norm here for several years, 2 story's usually have piss poor access. Very scary some of the time. I have turned jobs down because of it.
  12. Replies
    3
    Views
    512

    Advise for new gauges...

    I just bought a set of digital gauges. SMAN-4. I also got a set of hoses with the ball valve shut off. I have always carried two sets of analog gauges, one for r-22 and one for 410a. Both with low...
  13. Replies
    13
    Views
    1,237

    I appreciate all the responses. That gives we a...

    I appreciate all the responses. That gives we a lot to look at & consider. I understand how poor airflow would affect efficiency but could somebody explain how it would cause compressor failure?...
  14. Replies
    13
    Views
    1,237

    Shorted compressor question

    I had a call yesterday where a 2 year old 410a compressor was shorted to ground (Trane XB13). I checked it at the compressor terminals. It is a 5 ton split unit (cool only). I don’t have any history...
  15. Thread: candle soot

    by SinCityKid
    Replies
    16
    Views
    1,356

    Electric candles ...

    Electric candles

    http://www.batteryoperatedcandles.net/
  16. Replies
    13
    Views
    4,304

    Go home A/C, your drunk

    Came across this condenser the other day. Homeowner said he backed into it with a backhoe 9 years ago. Said he has never had 1 problem with it and it worked well. I was there to work on the other...
  17. Replies
    7
    Views
    927

    ahhh. that makes sense. Thx

    ahhh. that makes sense. Thx
  18. Replies
    7
    Views
    927

    Fan motor mystery???

    I went to a no cool call yesterday. 5 ton ICP heat pump split unit. Owner said that nothing was running on the condensing unit so he hit the top of it with his fist and the fan began to run but not...
  19. Replies
    9
    Views
    1,096

    I'm not going to move it. But for my educational...

    I'm not going to move it. But for my educational sake isn't the high side pressure the same between the compressor and the metering device +\- a couple psi?
  20. Replies
    9
    Views
    1,096

    So just cut the old one out and sweat in a...

    So just cut the old one out and sweat in a Schrader valve for the Mars option? PITA for a simple valve. Thanks for the info though!
  21. Replies
    9
    Views
    1,096

    It is running like that. We have highs of 112 and...

    It is running like that. We have highs of 112 and lows at night are 95 so my options are limited. I like your suggestion of tapping into the service port for a temporary pressure switch and I will do...
  22. Thread: Microfarads

    by SinCityKid
    Replies
    12
    Views
    1,211

    Microfarads

    Can anyone please explain to me exactly what a microfarad is and it's relationship to PSC motors and run caps in plain English. I know how to measure them on caps and match them to motors but that...
  23. Replies
    9
    Views
    1,096

    Pressure switch question...

    4 ton straight cool York condenser. 410a

    Mod#TCGF48S41S1A

    Ambient hit 112 last Saturday and unit shut down. When I got there I noticed the high pressure switch was open. Attached gauges and...
  24. Replies
    26
    Views
    6,283

    What problem did this cause that couldmt be...

    What problem did this cause that couldmt be covered by waranty?
  25. Replies
    5
    Views
    1,405

    condiot is conduit is conduit...

    Stopped for some Mexican food in San Diego. Looked up and saw this. For what it's worth the food was fricken delicious!

    369081369091369101
  26. Replies
    1
    Views
    859

    Help with Lennox condensing fan motor

    I need help determining the proper OFM & blade for 2 identical Lennox condensers (straight cool). I have a job at a bank repossessed house and someone stole both of the condensing fan motors and fan...
  27. The cap looks like it woulda fit right back in...

    The cap looks like it woulda fit right back in the hole.
  28. Replies
    4
    Views
    1,165

    I just noticed that they are using white wires...

    I just noticed that they are using white wires for the "hot legs". I suspect it doesn't really matter at that point...
  29. Replies
    14
    Views
    2,356

    Franken-Condenser

    Work with what ya got... I guess...

    353401
  30. There's more than one way to wire a water heater

    GROUND optional...

    353391
  31. Replies
    4
    Views
    1,165

    Breaker Breaker one nine

    Just had to get a picture of this. Owner thought it was funny that I found it "so interesting".353381
  32. Replies
    3
    Views
    816

    Reversing Valve Education

    Yesterday I replaced a compressor on a 4 ton Trane heat pump (R22). Compressor had an open winding... anyway the change out went relatively smooth however I was only getting about a 10 degree split...
  33. Replies
    5
    Views
    739

    Rundawg that is twice you have bailed me out!...

    Rundawg that is twice you have bailed me out! Thank you sooooooooooo much!!!!!
  34. Replies
    5
    Views
    739

    Trane Schematic

    Can anyone please come up with a schematic for a Trane BWC060D100JA. The sticker is loooooooong gone.

    Thanks in advance!
  35. Replies
    20
    Views
    2,946

    Hahaha you funny. I was invited "through" the...

    Hahaha you funny. I was invited "through" the house to see about a possible job out back. I don't know how it is where you live but if I stop in the house and start putting my wrench on his equipment...
  36. Replies
    20
    Views
    2,946

    Water Heater Woes

    Walked through a house to access the backyard and came across this water heater. 2 draft hoods??? and that is electrical tape sealing the top of the flue pipe. I told the property owner we should...
  37. Thread: PEE-YEW

    by SinCityKid
    Replies
    7
    Views
    1,902

    PEE-YEW

    Stopped for lunch and saw these apartments next door. Every condensate line is run into a sewer vent. No traps (not that it would help out here anyway).
  38. Replies
    10
    Views
    1,622

    Some more...

    Some more...
  39. Replies
    10
    Views
    1,622

    Contractor Awards

    Here are some photos that were sent to me. Not so much HVAC but definitely belong on the WOS.
  40. Replies
    20
    Views
    4,114

    I would be pi$$ed if that was my apartment...

    I would be pi$$ed if that was my apartment window...
  41. Replies
    3
    Views
    577

    Thick socks.

    Thick socks.
  42. Replies
    10
    Views
    8,362

    It is an older gas fireplace. Built with the...

    It is an older gas fireplace. Built with the house in 85. There is a gas valve to the side of the fireplace and a gas line that goes into the fireplace and it has little holes along the length of it....
  43. Replies
    10
    Views
    8,362

    Sand in fireplace

    Gas company came out to turn on the gas in a house the other day. I wasn’t there but they left a note saying I needed to cover the gas line in the fireplace with sand & I could then put the...
  44. Replies
    93
    Views
    6,613

    Here is a 28 second video from “Dr. Zarkloff”....

    Here is a 28 second video from “Dr. Zarkloff”. Consider this video when you take advise from him…

    http://www.youtube.com/watch?v=DznV2lyIyRA
  45. Replies
    40
    Views
    7,588

    Makes a great coat rack!

    Makes a great coat rack!
  46. Replies
    21
    Views
    3,046

    Well my textbook does say to vacuum it to 500...

    Well my textbook does say to vacuum it to 500 microns and we did cover that in the classroom, but when we actually did recovery out in the shop we just went off of Hg on our gauges.

    How long...
  47. Replies
    21
    Views
    3,046

    Micron Gauge

    The AC school I recently attended taught to go by Hg when evacuating a system. I can see from this website and others that a micron gauge should be used. My question is, do you just pump it down...
  48. Replies
    16
    Views
    4,004

    It's only a matter of time before he runs over...

    It's only a matter of time before he runs over that dog. Jackass...
  49. Replies
    78
    Views
    7,203

    Just remember… Your customer is a dirt bag. He...

    Just remember…

    Your customer is a dirt bag. He has proven this by the way he conducts his business. He has probably screwed people in the past and will continue to screw them in the future. His...
  50. Replies
    16
    Views
    1,636

    I do. I own several rental homes and it is part...

    I do. I own several rental homes and it is part of my annual inspection. It's been my experience that the valve will leak after testing it on an older unit so that is something to watch for, but...