Search:

Type: Posts; User: AcGolfer

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    33
    Views
    1,582

    How about if you must put the wrong size in, you...

    How about if you must put the wrong size in, you just get you sharpie marker and mark down the correct size inside control panel. I like to mark when I install parts anyhow.
  2. Replies
    40
    Views
    1,742

    A 2.5 ton compressor in a 3 ton condensor is like...

    A 2.5 ton compressor in a 3 ton condensor is like the new hi-efficiency units with the larger condensor coils. It could work OK for a/c but noway for a heat pump.
  3. Replies
    26
    Views
    3,276

    I went to the training class and my take on the...

    I went to the training class and my take on the speed is. In cooling we max out at 100% but in heating it can go up to 115%. So we'll get more heat in the winter.
  4. Thread: mop TXV

    by AcGolfer
    Replies
    3
    Views
    624

    Yes it does have a thermostat and a pumpdown, but...

    Yes it does have a thermostat and a pumpdown, but when thermostat opened solenoid the pressure only went up to about 15# and never made LP control set around 18psig.

    This setup work ok with r-12...
  5. Thread: mop TXV

    by AcGolfer
    Replies
    3
    Views
    624

    mop TXV

    Hi, a little background. Old R-12 walkin freezer with bad compressor.
    Our company put in new compressor and converted to 416A and adjusted TXV superheat.
    Freezer has a pumpdown solenoid and a...
  6. Replies
    26
    Views
    1,904

    Garmin seem slightly better for locating houses,...

    Garmin seem slightly better for locating houses, but better interface with TOMTOM.

    My biggest complaint about TOMTOM is fastest route is always the interstate or freeway as they call it. Could be...
  7. Thread: Chest Freezer

    by AcGolfer
    Replies
    10
    Views
    996

    old GE

    Thank jim, educated guess of the age of the freezer/compressor?
  8. Thread: Chest Freezer

    by AcGolfer
    Replies
    10
    Views
    996

    pic of comp

    Here some pics, has anyone seen a compressor like this?

    The first pic, right side is the wire going to comp.

    Still running with temp fan, haven't really figured how to change fan if I do it....
  9. Thread: Chest Freezer

    by AcGolfer
    Replies
    10
    Views
    996

    old compressor

    That what I worried about a new one won't last as long as this one after I fix it.
    More than likely will just leave a pc style fan in front of it for a year or two. Hard to access and worried about...
  10. Thread: Chest Freezer

    by AcGolfer
    Replies
    10
    Views
    996

    That a good option, the freezer in the basement...

    That a good option, the freezer in the basement so it not critical but that would keep it out of the way.
  11. Thread: Chest Freezer

    by AcGolfer
    Replies
    10
    Views
    996

    Chest Freezer

    Well my freezer condenser fan finally went out today, it been noisy for awhile off and on. Temporary put a small household fan in front of condenser, working fine.

    It has the strangest...
  12. Replies
    32
    Views
    1,524

    I use to wear Red Wing, the cheaper one, and had...

    I use to wear Red Wing, the cheaper one, and had to resole and toe sealed, lasted maybe 2 years.
    Switched to Wolverine 27 months ago with no problems and more comfortable.
    Just brought my new pair...
  13. Replies
    22
    Views
    4,527

    don't call me

    My question when I go on these kind of calls is why they didn't call the company/person that put it in.
  14. Replies
    11
    Views
    779

    Not too many years ago they had standing pilots...

    Not too many years ago they had standing pilots that wasn't 100% shut off.
    That mean if pilot went off it would not allow main gas but pilot gas remained, not allowed on LP gas.
  15. Replies
    15
    Views
    1,627

    I would make a note with a marker on the...

    I would make a note with a marker on the condensing unit the original MFD rating so the next time it goes out the tech know what size was in it. Or you could end up with a 60mfd if the next tech...
  16. biflow TXV

    Just a few weeks ago I came across a similar problem with a self contained Geotherm unit.
    It was a ClimateMaster with a biflow TXV, so like you described no true liquid line.
    I did call the...
  17. Replies
    0
    Views
    255

    Leak Detector around antifreeze

    I was doing a leak search yesterday on a geothermal. Second stage out of refrigerant, R-22 system.
    I using a good D-TEK Select Infrared Leak Detector. I disconnect the water heat exchanger and...
  18. Replies
    15
    Views
    1,682

    rollout sw

    I would be questioning why the rollout switch didn't open.
  19. Replies
    35
    Views
    4,432

    HP=high performance

    ROFL:D
  20. Replies
    17
    Views
    902

    open windows

    At 9:00pm open windows and I be out in morning.
    We try to charge the customer the different between regular and overtime.
    Yes we love it, been broken all week and now you call me.
  21. ROFL:)

    ROFL:)
  22. Replies
    12
    Views
    936

    vertical bulb

    I thought years ago they gave direction for mount bulbs- o'clock thing and when mounting vertical capillary line must face up.
  23. Unfair to Carrier

    Seems bad to blame Carrier for a bad capacitor that could not be diagnosed by a so called technician, he was probably just a installer.
    When talking to any tech support a little knowledge of the...
  24. Replies
    18
    Views
    1,530

    I was there last Sunday and notice the same...

    I was there last Sunday and notice the same thing. Made a comment about it to one of the other tech at our shop about it Monday.
  25. Replies
    14
    Views
    1,114

    Carrier Infinity

    Carrier Infinity
Results 1 to 25 of 31