Search:
Type: Posts; User: Chomper
Search: Search took 0.01 seconds.
-
02-26-2008, 08:32 AM
Thread: solid state starters
by Chomper- Replies
- 6
- Views
- 544
I agree.
I agree.
-
10-27-2007, 06:51 PM
Thread: Trane scroll tripping breaker
by Chomper- Replies
- 16
- Views
- 1,650
Trane parts has them.
Trane parts has them.
-
10-14-2007, 10:01 AM
Thread: Trane TR-1 Drives
by Chomper- Replies
- 4
- Views
- 628
You are correct speed change will not occur until...
You are correct speed change will not occur until the reference is above the minimum Freq. In this case as stated by someone, your minimum is 20 Hz or 33.3 %. Be careful with the minimum reference....
-
06-03-2007, 08:47 AM
Thread: 11 HVAC's 11,000sqft
by Chomper- Replies
- 3
- Views
- 453
Sound like you need a professional to make...
Sound like you need a professional to make recommendations.
Regards. -
12-23-2006, 11:33 AM
Thread: Tandem recips with VFDs'
by Chomper- Replies
- 8
- Views
- 736
Nothing wrong with multiple motors on a drive....
Nothing wrong with multiple motors on a drive. Here is the criteria: [1] Total amps of motors must not exceed the drive rating. [2] HP of all must be equal.[3] Each motor must have its own OL relay....
-
11-23-2006, 04:36 PM
Thread: CVHE Transition fault
by Chomper- Replies
- 7
- Views
- 635
Actually, my earlier post is the recommended...
Actually, my earlier post is the recommended procedure to have some redundancy. The movement of the entire aux assembly can sometimes be an issue and this takes care of that.
-
11-22-2006, 09:17 PM
Thread: CVHE Transition fault
by Chomper- Replies
- 7
- Views
- 635
Your "I" problem is most likey caused by a...
Your "I" problem is most likey caused by a defective aux contact on the run contactor. The transition contacts are gold plated and can eventually fail. Take a standard relay and wire the coil in...
-
10-08-2006, 09:40 AM
Thread: CVHE NEEDS FIX
by Chomper- Replies
- 10
- Views
- 934
Dumb question. Did you check the 1st stage tang...
Dumb question. Did you check the 1st stage tang operator assembly?
It can give simular symtoms and is a lot less work.
Regards. -
They do not like to sell the boards by itself....
They do not like to sell the boards by itself. Try installing a standard contactor if the busses will allow and eliminate the constant 120 vac wire. Also make sure the Xformer will handle the...
-
08-25-2006, 08:54 PM
Thread: CVHE net oil pressure
by Chomper- Replies
- 5
- Views
- 613
2nd.....say what????
2nd.....say what????
-
08-19-2006, 09:22 PM
Thread: RTAA-IOM-3 AND 4
by Chomper- Replies
- 4
- Views
- 906
Trane.com
Trane.com
-
08-19-2006, 09:17 PM
Thread: RTTC TRANE COMPRESSOR
by Chomper- Replies
- 4
- Views
- 479
err, crane, maybe?
err, crane, maybe?
-
08-11-2006, 08:46 PM
- Replies
- 15
- Views
- 1,250
Here goes,4 contactors, Shorting, Start, run and...
Here goes,4 contactors, Shorting, Start, run and transition.
1. Shorting contactor pulls in forming center of Wye.
2. Start contactor pulls in starting motor in Wye.
3. Transition
Old way. ... -
08-07-2006, 09:48 PM
Thread: Chilled Water System not Cooling
by Chomper- Replies
- 8
- Views
- 849
Hmmm, Face and bypass maybe?
Hmmm, Face and bypass maybe?
-
Well, now I have an excuse not to work hard...
Well, now I have an excuse not to work hard anymore. LOL
-
Just saw your signature. I'm a liberal, I work...
Just saw your signature. I'm a liberal, I work hard, happy most days. Does that mean you only work hard to annoy others? LOL
-
05-27-2006, 03:18 PM
- Replies
- 42
- Views
- 3,397
You obviously don't read well. I ask a general...
You obviously don't read well. I ask a general question.
By the way which benefits are you willing to give up and pay for your self? -
05-27-2006, 02:26 PM
- Replies
- 42
- Views
- 3,397
Heres my 2 cents. I am proud to be union. With...
Heres my 2 cents.
I am proud to be union. With that said, everyone must decide what is best for them and theirs. I take offense to my union brothers using degrading words like"scab, rats etc." Most... -
05-20-2006, 09:59 PM
Thread: 4000 TONS OF REAL COOLING
by Chomper- Replies
- 26
- Views
- 2,235
Look on the bright side of the Bards. If the...
Look on the bright side of the Bards. If the entire plant is down, atleast you'll be cool.
enjoy. -
05-06-2006, 09:12 PM
Thread: Trane YCD 330 Economizers
by Chomper- Replies
- 4
- Views
- 1,315
See your friendly local Trane parts Dept.
See your friendly local Trane parts Dept.
-
05-04-2006, 06:33 PM
Thread: transfering r123
by Chomper- Replies
- 4
- Views
- 502
Nitrogen! Never. You must use a recovery machine.
Nitrogen! Never.
You must use a recovery machine. -
05-04-2006, 06:30 PM
Thread: Belt tension
by Chomper- Replies
- 18
- Views
- 1,516
Hey max, what are you smoking, or did you just...
Hey max, what are you smoking, or did you just miss a key?
LOL -
04-21-2006, 10:35 PM
Thread: Who can post on this forum?
by Chomper- Replies
- 4
- Views
- 595
Ouch!
Ouch!
-
04-19-2006, 08:29 PM
- Replies
- 15
- Views
- 1,015
Err, I think that is highly unlikly that all five...
Err, I think that is highly unlikly that all five reliefs would go at the same time. I could see one maybe. The chiller should have shut down on high head before that occurs. Then again, anything is...
-
04-16-2006, 08:05 PM
Thread: CVHE Dry Run
by Chomper- Replies
- 19
- Views
- 1,519
What about transition?
What about transition?