02-20-2011, 10:32 AM
Thread: Servicing R11 and R134a Machines
by jsherhvac- Replies
- 16
- Views
- 1,723
:ditto:
:ditto:
-
Are you sure you said what you meant to say?? If...
Are you sure you said what you meant to say?? If so please explain to me what takes place as far as contactor sequencing in the wye configeration to start chiller.
-
11-05-2010, 05:12 PM
Thread: Service Tech Generated Revenue
by jsherhvac- Replies
- 20
- Views
- 1,578
Thanks for all of the replies.:CU:
Thanks for all of the replies.:CU:
-
WHAT IF??? We just used air cooled equipment:LOL:
WHAT IF??? We just used air cooled equipment:LOL:
-
10-28-2010, 06:52 PM
Thread: Service Tech Generated Revenue
by jsherhvac- Replies
- 20
- Views
- 1,578
Service Tech Generated Revenue
I was wondering if there was a good rule of thumb on much revenue a tech should produce in say a year. I understand this is probally not the best forum to post this question in, but was interested in...
-
12-16-2009, 06:40 PM
Thread: glycol temp piping
by jsherhvac- Replies
- 3
- Views
- 443
What about renting the hose & victalic couplings...
What about renting the hose & victalic couplings from Trane Chiller Source, just pass the cost on to the customer then you are not stuck with the hose at the end of the job. Just an idea.
-
07-22-2009, 08:39 PM
- Replies
- 11
- Views
- 679
If you were talking to me, no I do not have any...
If you were talking to me, no I do not have any 19DH literature. Try carrier.com more than likely the literature is there just tough to find on thier site sometimes.
-
07-16-2009, 08:28 PM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Just wanted to say thanks for everyone's input. I...
Just wanted to say thanks for everyone's input. I told the customer about changing dip switch on ccp1 to disable ground fault, they changed compressor has running fine for three days now. We are...
-
07-15-2009, 10:32 PM
- Replies
- 11
- Views
- 679
Been trying to send email for 20 minutes now, my...
Been trying to send email for 20 minutes now, my outlook is not working.
-
07-15-2009, 10:30 PM
- Replies
- 11
- Views
- 679
The shaft shoulder measurement has everything to...
The shaft shoulder measurement has everything to do with the contact seal. In other words thats the main reason for this measurment.
-
07-15-2009, 09:56 PM
- Replies
- 11
- Views
- 679
Just wondering, have there been any seal problems...
Just wondering, have there been any seal problems with the machine. The email is on the way, sorry its taking so long to get back to you, these 12-14hr. days are begining to wear on me.
-
07-14-2009, 10:21 PM
- Replies
- 11
- Views
- 679
There is a spacer on the thrust end that can be...
There is a spacer on the thrust end that can be machined to get your shaft shoulder to casing measurment correct. Did you have to replace the rotor assembley, if so your new rotor is probably a...
-
07-13-2009, 08:23 PM
Thread: High oil temps on RTAC
by jsherhvac- Replies
- 16
- Views
- 1,505
Hey ChillerWisperer did your quote/signature come...
Hey ChillerWisperer did your quote/signature come from Dave at LaCrosse?
-
07-13-2009, 08:16 PM
- Replies
- 11
- Views
- 679
I have qite a bit of literature, all from...
I have qite a bit of literature, all from carrier.com which you probably already have. If you have any questions I could probably help. I have done 2 17ma40 rebuilds & probably 10-15 17s30 rebuilds...
-
07-12-2009, 11:08 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Thank you kind sir.:D I had the literature...
Thank you kind sir.:D I had the literature already just didn't see the note about the dip switch setting. I must of had my head up my butt. Thanks Again
-
07-12-2009, 10:30 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
[QUOTE=thegoodlistener;3859022]The info to...
[QUOTE=thegoodlistener;3859022]The info to disable the ground fault is in the literature , I honestly have never had to do it.
I could not find anything on disabling the ground fault in the... -
07-12-2009, 10:28 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
The literature says "detected current to ground...
The literature says "detected current to ground 2.5 amps +/- 2 amps" = ground fault alarm.
-
07-12-2009, 02:04 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
[QUOTE=thegoodlistener;3859022]The info to...
[QUOTE=thegoodlistener;3859022]The info to disable the ground fault is in the literature , I honestly have never had to do it.
I will read up on that thanks for the info. If you think of anything... -
07-12-2009, 02:02 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Thanks for the info, and yes I megged motor all...
Thanks for the info, and yes I megged motor all six leads to ground and all leads to each other just to be sure.
-
07-11-2009, 05:05 PM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
No I have not, I was not aware I could do that. ...
No I have not, I was not aware I could do that. Do you happen to have any literature on the chiller. I downloaded what I could off of the carrier site.
-
07-10-2009, 07:37 PM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
The version 26 board is for the compressor that...
The version 26 board is for the compressor that is tripping.
-
07-10-2009, 09:19 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Chiller#2 M/N 30HXC206RY-540BA S/N 0702Q01190
Chiller#2 M/N 30HXC206RY-540BA S/N 0702Q01190
-
07-10-2009, 07:49 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
CCP board 1 for compressors a1 & b1 which was...
CCP board 1 for compressors a1 & b1 which was recently changed is rev. 26
CCP board 2 for compressor a2 which came on machine from factory is rev.23 -
07-10-2009, 07:42 AM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Exv position was around 47%, I did ohm out the...
Exv position was around 47%, I did ohm out the exv, checked perfect per the literature I have (25 ohms +/- 2 ohms I believe it was) also watched voltage go up and down as motor opened and closed
-
07-09-2009, 09:20 PM
Thread: Carrier 30HXC206
by jsherhvac- Replies
- 26
- Views
- 1,857
Customer has already replaced torrid sensor(sorry...
Customer has already replaced torrid sensor(sorry I referred to as CT) but I will take another look at that. Thanks for the help.