    Awesome systems and they are great people to work...

    Awesome systems and they are great people to work with. Go with the Heat Pump Pro panels - even if the systems are not HP's - much more asjustemnts. Always mount the panels on a basment block wall...
  2. Wow! $4.19 per gallon now. I would shop around...

    Wow! $4.19 per gallon now. I would shop around for LP suppliers - there can be a large difference between local companies. Most of our customers are in the $2.19 - 2.39 range right now. Also...
  3. Replies
    29
    Views
    1,508

    Make sure they set the furnace up "two pipe" - so...

    Make sure they set the furnace up "two pipe" - so it draws combustion air from outside. Also - the 72k btu furnace is BIG for a "small" house in upstate NY.
  4. Replies
    9
    Views
    664

    A plugged drain line is a pretty common problem...

    A plugged drain line is a pretty common problem with AC's - and can cause a lot of damage! We have been installing EZ-traps on all of our AC and HP systems for a few years. They are a clear trap...
  5. Ditto - what Earl Said. Make sure a heat...

    Ditto - what Earl Said.

    Make sure a heat loss is done so new unit is not oversized. Consider a modulating boiler like the Bosch Greenstar. You have Cast Iron baseboard that works very nice...
  6. Replies
    2
    Views
    376

    Hey neighbor! I would strongly receommend...

    Hey neighbor!

    I would strongly receommend pulling the furnace and installing a dedicated 95%+ model. Would access to natural gas, I would do that in a heart beat!! I work for a fuel oil/heating...
  7. Replies
    9
    Views
    963

    Match up of coil and outdoor unit MUST be a...

    Match up of coil and outdoor unit MUST be a documented match. Have your contractor show you the AMANA documented matchup in their literature or thru the AHRI website (third party that rates AC match...
  8. Replies
    22
    Views
    2,108

    Right now 50 - 50 on oil versus LP. LP has been...

    Right now 50 - 50 on oil versus LP. LP has been somewhat cheaper to run with the last couple years, compared to oil - but spiked this past winter, with some availability problems in some areas.

    I...
  9. Replies
    6
    Views
    369

    Size the vent correctly to the model and size of...

    Size the vent correctly to the model and size of your unit - look in the manual.
  10. When you did the heat loss/gain manual J - did...

    When you did the heat loss/gain manual J - did you include that the ducts will be in the attic? Makes a huge difference on sizing the system.
  11. I agree - tough situation. Recommended Zoning as...

    I agree - tough situation. Recommended Zoning as the system/building is already done - would help - benefits would depend how bad the system really is and how much duct we have access to.
  12. Replies
    17
    Views
    917

    I feel the Tranes are better systems. And I like...

    I feel the Tranes are better systems. And I like the idea of the media air filters. Helps keep the new high efficiency coils and blower clean.
  13. Are the ducts in the attic sealed and insulated? ...

    Are the ducts in the attic sealed and insulated? You could be losing most of your heat there. Very tough to heat 3 levels with one unit/tstat. Look at Arzel Zoning.
  14. Replies
    7
    Views
    424

    Start a service plan, so maybe he/she could do...

    Start a service plan, so maybe he/she could do service and cleans in the off season. Around here, heating is our big season and we were always way slower during the summer. We have gradually...
  15. Replies
    3
    Views
    389

    If you are replacing it, do not put another one...

    If you are replacing it, do not put another one that size back in. Chances are it is WAY oversized. That is a huge furnace.
  16. Replies
    14
    Views
    985

    When they reinstall - they need to have support...

    When they reinstall - they need to have support under both ends of the furnace AND the middle - where the seam of the two doors are. So - THREE total supports! And those supports should run the...
  17. Thread: Mini splits

    by edbrown
    Replies
    29
    Views
    1,765

    No traps in the drain, even a slight one (vinyl...

    No traps in the drain, even a slight one (vinyl or pvc) will cause the condensate to back up into the unit. If we have to run horizontal or a long run, we upsize the drain to 3/4" PVC to prevent...
  18. Replies
    9
    Views
    774

    I dont have my books, but those look like ducted...

    I dont have my books, but those look like ducted units? I have quoted the Mitsu a couple times, but have not gotten the jobs. They tell me that those unit have very little static to work with -...
  19. Replies
    2
    Views
    315

    We install media filters (Aprilaire) on almost...

    We install media filters (Aprilaire) on almost all of our 90% furnace installs - to keep the blowers/coils clean. As long as air is moving thru them - they are working. If the H/O has allergies or...
  20. Replies
    7
    Views
    542

    Yeah, typically a 80 degree A or B nozzle. >60...

    Yeah, typically a 80 degree A or B nozzle. >60 or .65 is usually more than enough. Make sure you use Kerosene in the outside tank, when ODT is below freezing.
  21. Replies
    19
    Views
    1,677

    pictures!!!!

    pictures!!!!
  22. Replies
    10
    Views
    888

    how about pic of the furnace? That control was...

    how about pic of the furnace? That control was on units WAY before blinking lights!
  23. let us/me know what air to water system you find...

    let us/me know what air to water system you find out there. I have never looked at those options, but have been very successful with the Mitsu air to air HP's ./
  24. Replies
    39
    Views
    2,029

    In your case a MHK-1 remote mount TSTAT would be...

    In your case a MHK-1 remote mount TSTAT would be the best. Gives full control like a thermostat. See link. http://www.mitsubishicomfort.com/en/consumer/product-solutions/product-showcase/controls
  25. Radiant allows for low water temp - which equates...

    Radiant allows for low water temp - which equates to high efficiency. fin tube baseboard must have much hotter water temp, lowering your efficiency of the system. I recommend going with radiant on...
  26. Replies
    39
    Views
    2,029

    Many of the Mitsu's have a 7 degree offset built...

    Many of the Mitsu's have a 7 degree offset built into the board. Either set the TSTAT where it is comfortable and forget the number (warmer or colder) OR their may be an overvride on the board. ...
  27. Replies
    19
    Views
    1,677

    We need pictures!!! Unbelievable that this high...

    We need pictures!!! Unbelievable that this high end equipment is installed this poorly.
  28. Replies
    19
    Views
    1,677

    pictures??

    pictures??
  29. I felt bad with my last comment - I forgot to say...

    I felt bad with my last comment - I forgot to say that overall the ductwork looks amazing. What a difference from the old system to the new!
  30. The goodman furnaces - Thought for 1600-2000 CFM...

    The goodman furnaces - Thought for 1600-2000 CFM (4-5 ton), you needed to use both sides of the furnace.......? You are probably not moving enough air with the 2 split sytems.
  31. Replies
    35
    Views
    2,104

    We have had this problem many times over the...

    We have had this problem many times over the years with LP setups. Many manufacturers do not actually test their systems with LP in the lab/factory. The last time was with a bunch of Utica...
  32. I have 2 Mitsubishi Hyper heat units in my home...

    I have 2 Mitsubishi Hyper heat units in my home and we have been installing them since 2003. We install roughly 90-100 (outdoor unit) systems a year - with very limited issues. Most problems are...
  33. Go with a Mitsubishi Mr Slim Hyper heat unit -...

    Go with a Mitsubishi Mr Slim Hyper heat unit - much more efficienct than baseboard and you can run the unit in summer for some de-humidification.
  34. Cleaning the burners and adjusting the setup will...

    Cleaning the burners and adjusting the setup will probably reduce the CO. Call a reputable company.
  35. What type of equipment is installed in the...

    What type of equipment is installed in the chimney where the liner was removed? What is the chimney made of? Height?
  36. Replies
    15
    Views
    1,524

    A package unit would typically be 80% efficient...

    A package unit would typically be 80% efficient on the gas side, compared to your 60-65% efficient Empire - resulting in some LP savings. I agree with planning on filters in the duct system. I also...
  37. Replies
    2
    Views
    891

    Do not "monkey with the settings"! The Logomatic...

    Do not "monkey with the settings"! The Logomatic trys to keep the water temp in the boiler at a constant temperature in relation to the outside temps and heat needed in the house. The control will...
  38. Replies
    12
    Views
    1,000

    Stack/Flue temp is a really important spec here -...

    Stack/Flue temp is a really important spec here - to ensure that the fumes are not condensing in the flue/chimney. The TP OL6 was mentioned and that is a GREAT furnace. But we find that they are so...
  39. Replies
    3
    Views
    501

    Arzel panel vibration noise

    We have an Arzel Heat Pump Pro installed on an attic system. The panel is mounted in the attic to the framed trusses. The noise from the compressor running vibrates down into the kitchen...
  40. Replies
    3
    Views
    1,357

    I am a Trane dealer and just ran into this for...

    I am a Trane dealer and just ran into this for the first time. We have 2 C/E on a system and homwowner is complaining of ozone odor. We are going to run the fan all the time - variable speed - to...
  41. Replies
    13
    Views
    2,767

    So the white tank is a buffer tank? Is this to...

    So the white tank is a buffer tank? Is this to increase the water capacity in the system and reduce short cycling?

    Installed many Mon/Cons - never with a buffer.
  42. Thread: Winter Gear

    by edbrown
    Replies
    24
    Views
    2,188

    Layers!! So you can take off or put on as...

    Layers!! So you can take off or put on as needed. Also can switch out layers as they get wet. If you are going to be outside - Winter boots (not just work boots) - and Carhart bibs to keep the...
  43. Replies
    13
    Views
    1,983

    Blower motor going the correct direction? Too...

    Blower motor going the correct direction?
    Too big for the house/ductwork?
  44. Replies
    1
    Views
    1,183

    Empire Mantis - 90%+ fireplace insert

    Any feedback for homeowners that have these units? How are they holding up? I have a large original wood fireplace in my "new to me " home (is actually 200 years old!) and was planning on...
  45. How about a drawing.... It is tough to figure...

    How about a drawing.... It is tough to figure out what you are trying to say.
  46. Replies
    14
    Views
    1,674

    we are going thru this at our office. Sand them...

    we are going thru this at our office. Sand them down and recoat them.
  47. Replies
    15
    Views
    2,196

    I would look at Mitsubishi Ductless - great...

    I would look at Mitsubishi Ductless - great de-humidification and you get zoning and complete control for each room.
  48. Replies
    7
    Views
    1,167

    These units are great but when we have the rare...

    These units are great but when we have the rare problem call - they can be tricky to diagnose. They have many different sensors.

    IS the air filters, coils, and blower wheel clean in the indoor...
  49. Have the installers set up the blower correctly -...

    Have the installers set up the blower correctly - as said before.

    We see this ALL the time!! Even occasionally from our installers - that is wh our Home Comfort Consultants (Salesman) always go...
  50. Replies
    4
    Views
    954

    Are you talking about the "powerventer/fan" on...

    Are you talking about the "powerventer/fan" on the unit? or a field added model?

    Ignitor ohms and proper clearance to burner?

    Gas manifold pressure correct?

    I also believe this has a...
Results 1 to 50 of 459
Page 1 of 10 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event