Search:

Type: Posts; User: BACNet Jr.

Search: Search took 0.00 seconds.

  1. Danfoss FC102

    Danfoss FC102
  2. Sorry for very Danfoss FC-102

    Sorry for very Danfoss FC-102
  3. Replies
    8
    Views
    610

    BACNet Electronic Door

    Is it possible that an electronic room on AHU room that will be connected to other BACNet device such as ddc, vfd, and control valves.

    We have 20 AHU room and one building and there is an existing...
  4. Replies
    5
    Views
    579

    http://nae00108d03c25b/metasys/

    http://nae00108d03c25b/metasys/
  5. Translate PT1000 sensor signal to celcius

    HI! i have three PT1000 sensors connected to a FC-102 VFD and the VFD is networked to a metasys NCE25. Upon opening the Metasys tree of the particular VFD. All the sensor reading are on %. How do i...
  6. Replies
    5
    Views
    579

    how to open ready access portal?

    A new nce25 has just been delivered and install it in the network of vfds. The metasys was able to read all the values on the device connected.

    Question here is how to open ready access portal?...
  7. Replies
    2
    Views
    923

    JCI Metasys on Android OS?

    Is it possible to run a metasys on your cellphone and tablets? Just for monitoring and controls of the Centralized Air Conditioning System.
  8. Replies
    2
    Views
    687

    JCI Metasys on Android OS?

    Is it possible to run a metasys on your cellphone and tablets. Just for monitoring and controls of the Centralized Air Conditioning System.
  9. How to connect a Johnson Controls NAE35 to wifi?

    I have 1 NAE35, 1 PC, 2 Laptops, and 1 wireless router with 1 WAN, 3 LAN ports in the office. What else do I need so I can monitor and control the NAE35 system? and How I can do it?
    :grin2:
  10. Convert a Personal Computer to a BACNet Router and Controller

    I have an RS-485 to USB converter. How i can router 23 MSTP device to ethernet using BACNet software only.

    Any BACNet Software
  11. Replies
    0
    Views
    901

    Citect Facilities BACNet Compliance

    Anyone used Vijeo Citect Facilities here?

    Has the Citect Facilities been BTL Listed?

    I had downloaded PICS from the BACNet Driver of the Citect Facilities

    --------

    BACnet Protocol...
  12. Replies
    8
    Views
    1,345

    I just need to schedule to switch on and off the...

    I just need to schedule to switch on and off the equipments.

    So I can use LGR250 for about 1000 bacnet points for real time monitoring on the other bacnet device (danfoss vfds and kmc) in my...
  13. Replies
    8
    Views
    1,345

    So display objects can be excluded to 250 points...

    So display objects can be excluded to 250 points of LGR?

    Are the points for monitoring temperatures sensors, pressure transducers, vfd % speed, Power reading are considered "display objects"?
  14. Replies
    8
    Views
    1,345

    How many points I can really integrate to the...

    How many points I can really integrate to the LGR250 using BACNet protocol on these equipments.
  15. Replies
    8
    Views
    1,345

    ALC LGR-250 250 points?

    We being are being offered by an local ALC dealer with LGR250 router. We will gonna integrate 25 units of Danfoss VFD and ten units of KMC 8X8 controller using BACNet Protocol.

    The dealer's...
  16. Replies
    13
    Views
    4,407

    Is there also a demo program for webctrl?

    Is there also a demo program for webctrl?
  17. Future of Centralized Air Conditioning System

    What are the possible systems that may be used in the future?

    Would a ducted system be replaced by fan coil units with supply of fresh air and has an exhaust be in place of a VAV system? And are...
  18. Need Centralized Air Conditioning System Diagram

    Good day!

    I having a presentaion in our office about centralized air conditioning system and I need a prespectic diagram showing all Chillers, AHUs, Pumps, Cooling towers, etc on the diagram.
    ...
  19. Replies
    6
    Views
    1,432

    VFD on reciprocating compressor

    What happens when i put a VFD on a 20 TR reciprocating compressor?

    What happens when i slow down the motor? I want the unit to reduce the refrigerant flow when in part load like the VRF.
  20. Replies
    2
    Views
    694

    Air Handling Unit Paint

    We have 50 units of air handling units and all are 30 years old. I wan to strip down its old paint to metal and change its coating. I would like also to paint the inside component like its blower.
    ...
  21. Connecting 2 MS/TP segment to Reliable Mach-Pro-Com

    Based on the Specs of Machprocom, machprowebcom, machprosys, and machprowebsys these controllers has 2 EIA-485 @ 76.8 kbps max. But I do not know if the second EIA-485 can be used for BACNet.

    Can...
  22. KMC or Reliable. The local integrator says...

    KMC or Reliable.

    The local integrator says that we buy a BACNet IP router or a Building Controller with IP so that we can monitor and control our equpment thru PC.. He says that the MS/TP...
  23. BACNet MS/TP connection only OWS PC is okay?

    One of the building i handled will be upgraded with new hvac controls. I just want to schedule on and off of the Air Conditioning units, and to monitor and adjust its set points. There will be some...
  24. Replies
    6
    Views
    841

    I just need so website like RS Online to have...

    I just need so website like RS Online to have some catalog and prices on hvac controls
  25. Replies
    6
    Views
    841

    HVAC Control prices

    Asking for some link to find hvac controls prices catalog particullarly in building automation.

    This is for budget preparation.
  26. Replies
    7
    Views
    1,211

    Can the BACstage software be used to other...

    Can the BACstage software be used to other controller. Like if you had a reliable ddc or other bacnet device?
  27. Thanks for the reply above.. Yes, al the...

    Thanks for the reply above..



    Yes, al the logic are handled internally in this brand, you can either configure it using the VFD display panel or you can use software that connect the VFD to a...
  28. Danfoss VLT HVAC - FC-102.. The VFD has internal...

    Danfoss VLT HVAC - FC-102.. The VFD has internal fieldbus controllers and BACNet communication.

    here are similar applications from the ABB drives
    ...
  29. The VFDs has a built-in BACNet MS/TP on it. ...

    The VFDs has a built-in BACNet MS/TP on it.

    Pls explain?


    Can I use the Building Controller from reliable like the MachProCom or from KMC and connect the 100 VFDs on it? and the building...
  30. Using VFD to communicate directly to BMS without using DDC

    Hi! I am currently searching for a solution using Danfoss FC-102 as an AHU controller and directly communicate with BMS, and that VFD has an integrated BACNet MS/TP port. The VFD in my project has 5...
Results 1 to 30 of 32