  1. New Trane ComfortLink II XL950 Thermostat

    Hello,
    I have a new trane comfortlink II thermostat for sale. $435.00 shipped. Message me if interested.
  2. Replies
    86
    Views
    6,341

    I agree. I don't know why we replace so many...

    I agree. I don't know why we replace so many turbasheds. My only thought was the impingment screen on the outside wall of the helical separator may get partially plugged over time. I don't know why...
  3. Replies
    86
    Views
    6,341

    Nothing wrong with either setup. They both work...

    Nothing wrong with either setup. They both work fine. Just saying there's nothing wrong with switching oil systems.
  4. Replies
    86
    Views
    6,341

    I've never seen one fail but I've seen many...

    I've never seen one fail but I've seen many changed out. So there's no impingement screen inside a helical oil separator?
  5. Replies
    86
    Views
    6,341

    Kind of on the same lines as jp you gotta make...

    Kind of on the same lines as jp you gotta make sure all floats are not over full. Sometimes you run in to a situation with ems and a oversized rack/small load where one comp will never run and it...
  6. Replies
    86
    Views
    6,341

    Whats wrong with removing a bad turbashed and...

    Whats wrong with removing a bad turbashed and installing separator and reservoir low pressure oil feed system? I do the same setup as jp to test if separator is working. I also will valve one off for...
  7. Replies
    18
    Views
    1,028

    What force in a ice machine do you think would...

    What force in a ice machine do you think would cause a magnet to lose it's magnetism?
  8. Replies
    5
    Views
    497

    So safeway has known leaks and doesn't want to...

    So safeway has known leaks and doesn't want to pay to have them fixed? I've never worked at a safeway but the 200 markets we service always want all leaks fixed right away without question....
  9. Replies
    21
    Views
    1,484

    Being low on charge can cause an oil trip.

    Being low on charge can cause an oil trip.
  10. Replies
    56
    Views
    2,476

    Is the cost of modifying this going to be more...

    Is the cost of modifying this going to be more than a new under counter cooler? You'll have to remove the old evap, install txv and custom fit the new evap, modify the refrigerant piping and...
  11. Replies
    11
    Views
    1,015

    Ridiculous and uncalled for. Just saying its not...

    Ridiculous and uncalled for. Just saying its not that easy to adjust setpoint at walmart. Sorry.
  12. Replies
    11
    Views
    1,015

    [QUOTE=Phase Loss;16417911]You can use the "super...

    [QUOTE=Phase Loss;16417911]You can use the "super user" code.

    Or call Wall-Mart monitoring & have them lower the temperature setpoint of the circuit.

    It's just for a short period during the...
  13. Replies
    11
    Views
    1,015

    You have special access codes?

    You have special access codes?
  14. Replies
    11
    Views
    1,015

    You can do that at walmart?

    You can do that at walmart?
  15. I was going to ask you the same thing. I was...

    I was going to ask you the same thing. I was surprised to hear the high suction with the evap fans off. Maybe someone didn't understand the wiring or changed it so it could be a cooler.
  16. lol yep been there

    lol yep been there
  17. I've had the exact same experience with there...

    I've had the exact same experience with there equipment and customer service. They once told me the serial number I gave them for a new blast chiller we installed was incorrect. I sat there looking...
  18. Thread: iced up !!

    by dangpgt97
    Replies
    25
    Views
    4,836

    Use a lift to get it out. I guess you could deice...

    Use a lift to get it out. I guess you could deice it, replace the drain pan and heaters, repair the drain line, repair the bent fan blades and possible some motors, replace whatever caused it to ice...
  19. Thread: iced up !!

    by dangpgt97
    Replies
    25
    Views
    4,836

    Probably called on a Friday at 4:00 like it just...

    Probably called on a Friday at 4:00 like it just happened. I wouldn't deice that. I would replace the evap.
  20. Replies
    15
    Views
    1,291

    Had one a few years back that was clogged like...

    Had one a few years back that was clogged like that. Had to replace compressor, cap tube and drier. Started back up and it was still restricted. Outlet of the condenser was plugged with the same kind...
  21. Replies
    44
    Views
    6,379

    Thats what I do. I gernerally dont make flares....

    Thats what I do. I gernerally dont make flares. On pressure controls, ultracap and things I make them tight and if they leak I tighten until they stop leaking. What else are you going to do. I've...
  22. Replies
    44
    Views
    6,379

    If you keep the crows foot at a 90 degree angle...

    If you keep the crows foot at a 90 degree angle to the torque wrench you dont have to adjust the torque setting. It's only if you have it parallel you have to adjust torque because obviously it...
  23. Replies
    18
    Views
    1,875

    You did the right thing. Only takes a few more...

    You did the right thing. Only takes a few more minutes to cut it out and replace it. I've been on a few calls working on roofs in -20 temps and 40mph winds where someone brazed over the rub through...
  24. Replies
    26
    Views
    1,731

    You set superheat at the evap. If the lineset is...

    You set superheat at the evap. If the lineset is short maintaining compressor superheat at 20* minimum is more important than evap superheat. I doubt that ambient would affect 2 ft of suction line...
  25. Replies
    26
    Views
    1,731

    Whats wrong with adjusting superheat to 25...

    Whats wrong with adjusting superheat to 25 degrees at the compressor? If you have a short suction line you still need a minimum of 20 degrees superheat at compressor. Do the performance curve for the...