  1. Replies
    12
    Views
    1,081

    What if the tech before you remove the TXV bulb...

    What if the tech before you remove the TXV bulb because Suct. pressure was too low, just to test it...after some test, 4h30pm friday, he decided to unplug c2 coil. Never went back there. Restriction...
  2. Replies
    3
    Views
    1,105

    Thanks, i will call Lennox tomorrow. Do you think...

    Thanks, i will call Lennox tomorrow. Do you think USOPTL4 from B&B Electonics will do the job for rs-485 to USB? I ask because i already have this converter, i use it when connectiong to a specific...
  3. Replies
    12
    Views
    1,081

    What you mean by "blockage"? An unfasten bulb...

    What you mean by "blockage"? An unfasten bulb will not block refrigerant. A loss of charge in bulb will. You're not very curious. Usually when you change a TXV, you have to test it. I suspect TXV was...
  4. Replies
    3
    Views
    1,105

    Lennox L Series Software

    I 'm trying to connect my laptop to a lca150 rtu with IMC card. Rtu is not part of a network. I have the L Connection Software found on Lennox website. What else do i need to acheive this at lowest...
  5. Replies
    46
    Views
    3,329

    Anyway those valves NEVER leak! :eek2:

    Anyway those valves NEVER leak! :eek2:
  6. Replies
    16
    Views
    3,085

    For those who are not working on ahu i'll explain...

    For those who are not working on ahu i'll explain how this system is working.
    First : ventilation.

    You got 2 blowers supply blower and return blower. the supply blower is located down right and...
  7. Replies
    16
    Views
    3,085

    Demo mini-AHU for Quebec Skills Games

    This is a project we've been working on for several weeks in school ( HVAC/R school ). It has been done by students from a to z. We have done 4 of theses working demo AHU. They will be troubleshooted...
  8. Replies
    28
    Views
    2,133

    Kink in liquid line would cause a pump down in...

    Kink in liquid line would cause a pump down in cooling.
    If set in heating..i agree it could cause high pressure issue since id coil doesn't hold the charge...usually when we say a relief valve is in...
  9. Condensate pump will only stop HP..Aux heat will...

    Condensate pump will only stop HP..Aux heat will still work..
  10. Replies
    15
    Views
    1,662

    A recording of the sound could help :) just a...

    A recording of the sound could help :)
    just a joke..

    Could be as simple as a noisy relay..
  11. Biggest problems occurs when the clear tube is...

    Biggest problems occurs when the clear tube is pinch..other than that they work well.
  12. Replies
    17
    Views
    1,391

    Is there a possibility to use a kind of power...

    Is there a possibility to use a kind of power exhaust fan to evacuate hot air and a damper to let fresh air enter...
  13. Replies
    2
    Views
    588

    Don't insulate the liquid line...Should not be...

    Don't insulate the liquid line...Should not be critical in heating mode but in cooling you want to be sure to have a good subcooling whick will help eliminate flash-gaz which will lead to a better...
  14. Replies
    7
    Views
    2,802

    I don't install Goodman but i though the...

    I don't install Goodman but i though the reversing valve was energized in cooling. It's kind of strange you had AC with 1cool/1heat tstat since they're not supposed to energize O. Maybe White Rogers...
  15. Replies
    7
    Views
    2,802

    Probably not a big problem...to solve Find a...

    Probably not a big problem...to solve
    Find a good tech with a good multimeter and you're in business.
  16. Replies
    10
    Views
    6,622

    [QUOTE=kwkheat;1703093] The guy who installed the...

    [QUOTE=kwkheat;1703093] The guy who installed the thermostat just said to switch over when the temperature stayed below freezing for several days.

    I'd say it depends where you live and electricity...
  17. Replies
    19
    Views
    1,574

    Huh, defrost wiil occur at temp over 35F since...

    Huh, defrost wiil occur at temp over 35F since your OD coil is below 32F..and since RH is higher at 35F than 15F as an exemple defrost will happen more often.


    To answer the main question, look...
  18. Replies
    24
    Views
    1,805

    Always better to put the coil in the return Why?...

    Always better to put the coil in the return
    Why?
    - Heat stages will work together. They can't if coil is in the supply because head pressure rise.
    - Coil isn't exposed to Aux heat
    - No need to...
  19. Replies
    8
    Views
    2,657

    I'm also surprised that a service tech doesn't...

    I'm also surprised that a service tech doesn't know which tx valve to check. NO DIY.
  20. Replies
    41
    Views
    4,646

    IMPOSSIBLE to freeze on the discharge line. The...

    IMPOSSIBLE to freeze on the discharge line. The only thing that could make it freeze is a big restriction...and if you have a restriction anywhere before the condenser your head pressure will go...
  21. Replies
    2
    Views
    756

    Superheat can tell ;)

    Superheat can tell ;)
  22. Replies
    27
    Views
    2,308

    I agree it sounds like a defrost. We can hear the...

    I agree it sounds like a defrost. We can hear the reversing valve through the piping in the furnace and then your docking help the sound transmission. W1 probably set to work on low speed that's why...
  23. Replies
    25
    Views
    1,866

    A coil completely frozen means you have enough...

    A coil completely frozen means you have enough refrigerant in your system since humidity will be ther only if there is refrigerant changing state. If it the coil is not completely frozen then it may...