Search:

Type: Posts; User: craig725

Search: Search took 0.00 seconds.

  1. Replies
    19
    Views
    2,854

    The new way of doing things?

    Apparently this is the way a new pre-manufactured home a/c unit is installed...looks like a hack job to me. Has anyone seen this sort of setup before? I bet it will not take long for the old coil...
  2. Replies
    8
    Views
    1,564

    I was recently at Totaline, and the class that...

    I was recently at Totaline, and the class that was give suggested that R-11 flush to be used.
  3. Thanks for pointing that out..I guess I missed...

    Thanks for pointing that out..I guess I missed that part, I still would not use the coil. If you are concerned, you can request to keep it and sell it on ebay or something if you so desire.
  4. Replies
    22
    Views
    1,622

    Do not be scared of R-22...There are far too many...

    Do not be scared of R-22...There are far too many R-22 systems out there to worry about getting refer. for it. As R-22 systems are changed out, the gas will be collected, cleaned and resold. If you...
  5. Thread: open windows?

    by craig725
    Replies
    10
    Views
    854

    If you need to get fresh air in the home, then...

    If you need to get fresh air in the home, then you want the air to enter though the unit so it is conditioned once in the living space. In high humid areas, an open window with the right conditions...
  6. If the evap coil is 14 years old I would not...

    If the evap coil is 14 years old I would not reuse with R-410a. The increased pressue of R-410a could cause the coil to leak. Do the right thing, and replace the coil. Remember a 14 year old coil...
  7. Replies
    106
    Views
    6,647

    Give me some address...I need new tools. :)

    Give me some address...I need new tools. :)
  8. Replies
    106
    Views
    6,647

    I wish I had that much time on my hands between...

    I wish I had that much time on my hands between calls.
  9. Replies
    106
    Views
    6,647

    When you are out somewhere and see a t-stat lock...

    When you are out somewhere and see a t-stat lock box, which you open with your key and make a little adjustment.:eek:
  10. Replies
    14
    Views
    1,678

    Consider upgrading the insulation in the attic...

    Consider upgrading the insulation in the attic above the second floor, could make some difference. With the rising costs of fuel, every bit will help.
  11. Replies
    106
    Views
    6,647

    You are walking through Home Depot wondering how...

    You are walking through Home Depot wondering how long it will take before the unit with the noisy belts freezes up and stops working.