Search:

Type: Posts; User: Indy

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    61
    Views
    3,301

    First of all this is how you spell DeLorean....

    First of all this is how you spell DeLorean. Secondly I made my post in 2011 stating that York's zone controller was due to be released in 2012. Why is that so hard to understand.
  2. Replies
    61
    Views
    3,301

    No I did not get the York zoning system. I sold...

    No I did not get the York zoning system. I sold my home.
  3. Replies
    4
    Views
    585

    Thanks...Updated my HG3 with no problems.

    Thanks...Updated my HG3 with no problems.
  4. Thread: A new player.

    by Indy
    Replies
    11
    Views
    1,104

    A new player.

    http://hilmor.com/products/family/manifolds

    Any one used or seen this yet?
  5. Replies
    29
    Views
    3,362

    No

    No
  6. I use self feeding drill...

    I use self feeding drill bits...[URL="http://www.youtube.com/watch?v=kYgwdObQxKw"
  7. I asked my wholesaler the same question a couple...

    I asked my wholesaler the same question a couple of days ago and they didn't have a definitive answer.
  8. Replies
    10
    Views
    2,332

    Hope you have a better experience with the...

    Hope you have a better experience with the quality of Western Enterprises line of VN products than I have had.
  9. Replies
    1
    Views
    637

    Check out the animated demonstrations at the...

    Check out the animated demonstrations at the bottom of the page. http://digi-cool.com/category/drsa-1250
  10. Replies
    12
    Views
    1,752

    You are correct on the location of the HP sensor...

    You are correct on the location of the HP sensor and the reason you are not seeing the HP on gauge.
  11. Replies
    13
    Views
    2,082

    http://www.trutechtools.com/SensitTKX Very...

    http://www.trutechtools.com/SensitTKX Very well built detector and made in the USA
  12. Replies
    20
    Views
    2,141

    Emerson's copeland brand of compressor's has...

    Emerson's copeland brand of compressor's has approved the use of the Spectroline brand of dye in their compressors. Only mfg that I know of that has given approval to the use of a dye.
  13. Replies
    1
    Views
    707

    29,000 BTU or 2 1/2 tons.

    29,000 BTU or 2 1/2 tons.
  14. Replies
    16
    Views
    1,748

    Since you said it was in cooling only I am...

    Since you said it was in cooling only I am leaning more towards the thermostat. Try and isolate which zone is calling for cooling when you notice the problem. If it is the thermostat at least you...
  15. Replies
    16
    Views
    1,748

    I had a call a couple of weeks ago that had the...

    I had a call a couple of weeks ago that had the same symptoms that you are describing. The unit would make a "audible noise" as you have mentioned. In my case the audible noise was coming from the...
  16. Thread: H-10g questions

    by Indy
    Replies
    10
    Views
    1,104

    I also talked with tech support and got a little...

    I also talked with tech support and got a little better answer than you did.

    "The manual for the H10 PM is currently under revision but the correct way to test for proper pump flow is to point...
  17. Thread: H-10g questions

    by Indy
    Replies
    10
    Views
    1,104

    I believe that the red ball is just for checking...

    I believe that the red ball is just for checking that the pump is working. Even if the ball is all the way towards the tip when held in a vertical position like you described it has no effect on the...
  18. Replies
    8
    Views
    895

    Not correct. The question is did your unit take...

    Not correct. The question is did your unit take 3yrs to leak 3lbs of refrigerant or did the unit just start leaking 6 months ago, last month, last week or yesterday.
  19. Replies
    34
    Views
    3,189

    I have never adjusted the pot on my H-10PM. I...

    I have never adjusted the pot on my H-10PM. I just set the selector to small when checking for 410A leaks and medium for R-22. These are the only two refrigerants that I deal with and I have never...
  20. Replies
    34
    Views
    3,189

    H-10

    The following is a quote from Bacharach on adjusting the H-10PM when checking a system with 410A. "For testing R410A you should use the SMALL leak mode setting and you should increase the heater...
  21. Replies
    1
    Views
    419

    Question for H10-PM users

    I just picked up a H10-PM today and need a little clarification on the settings when running in automatic mode. The manual says to use the medium switch position on R-22. The manual doesn't spell it...
  22. run time

    The run times are based on a algorithm programmed into the main control board. The furnace should operate at low fire (35%) for about 10 minutes and then ramp up to high fire within 20 minutes.(30...
  23. Replies
    14
    Views
    969

    Yes it is normal

    Yes it is normal
  24. Replies
    11
    Views
    1,582

    Woodland

    I wear these...Knee pads are gel and built into the pants. USA made.
    http://www.woodlandworkwearusa.com/
  25. Replies
    17
    Views
    1,399

    After I submitted the above comments a rep from...

    After I submitted the above comments a rep from fieldpiece contacted me and offered to swap out my HG3 for the updated version. It seems that I was one of the unlucky ones to get one of the earlier...
Results 1 to 25 of 173
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event