  1. Replies
    14
    Views
    1,516

    Think if it this way. When we perform system...

    Think if it this way.

    When we perform system start-up, verification, or whatever someone establishes a static pressure setpoint. This is the static pressure required to provide necessary air flow...
  2. Replies
    19
    Views
    2,812

    I would need to verify, but you can activate a...

    I would need to verify, but you can activate a profile in the MP581 or use it as a generic controller. You may want to connect directly to the controller and see if it using a SCC profile. Its been...
  3. Replies
    2
    Views
    555

    Maybe best for Logmein123 and internet access to...

    Maybe best for Logmein123 and internet access to the local workstation. If you went remote with laptop, then you need another copy of Summit. Plus, there would be a database in the BCU, on the...
  4. Replies
    4
    Views
    516

    They can easily be setup via site configuration...

    They can easily be setup via site configuration and event classes. You can define most alarms by going to the edit pages of equipment and inputs to tell what to do.

    Keep in mind that some alarms...
  5. Replies
    8
    Views
    1,070

    Based on PD = (gpm/Cv) squared A good rule of...

    Based on PD = (gpm/Cv) squared

    A good rule of thumb for control valves is pick your Cv at 50% of GPM, this will give your a DP of 4 which usually provides good control. Also, stay within 2 pipe...
  6. Replies
    3
    Views
    547

    Nope, logic is in the old MP581. Pretty rare from...

    Nope, logic is in the old MP581. Pretty rare from what I've seen for the LON card to crash, but happens. The programming is pretty straight forward. Is there a similiar unit there you can steal the...
  7. Replies
    3
    Views
    547

    You have mail.

    You have mail.
  8. Replies
    51
    Views
    5,535

    Not sure what exactly the issue is, but as far as...

    Not sure what exactly the issue is, but as far as Tampa versus Orlando - the hourly pay in Orlando is less - mid 20's with different bennies. Tampa is more with different bennies. No idea about Miami...
  9. Thread: BCU and BACnet

    by smokies
    Replies
    6
    Views
    1,155

    You need to change the BCU to IP. The workstation...

    You need to change the BCU to IP. The workstation has a program called IP Validation under the Tracer Summit program to do it. Its not bad, but you will need a serial cable form the PC to the...
  10. Replies
    2
    Views
    411

    BACnet OVerrride System

    I posted this before, but looks like it was in the jobs forum. I'm being told that Tenant Services is not available and I have a customer that wants it.

    Anyone have a similiar system that they...
  11. Replies
    9
    Views
    1,018

    What type of equipment are you trying to...

    What type of equipment are you trying to start-up? Are they BOP controlled or more VAVs through area and VAS?
  12. Replies
    14
    Views
    1,704

    Our control techs work all went through the UA...

    Our control techs work all went through the UA apprenticeship and all worked as service techs/ projects guys. They now install/program controls and still have to play service tech/ project guys. To...
  13. Replies
    14
    Views
    1,704

    Our service techs, fitters/welders, installers,...

    Our service techs, fitters/welders, installers, and even our control techs were all in the UA way before Emcor. Sheetmetal and insulators are not. I've been with the company for 18 years next month...
  14. Replies
    14
    Views
    1,704

    We were bought by Emcor a few years agao. They've...

    We were bought by Emcor a few years agao. They've been great and I haven't heard others that have been acquired having alot of changes. They stay away as long as the money is rolling in. Its been a...
  15. Replies
    17
    Views
    2,005

    Its good as long as your boss doesn't visit this...

    Its good as long as your boss doesn't visit this site.
  16. Replies
    10
    Views
    1,045

    Not sure, I went through a local vo-tech, which...

    Not sure, I went through a local vo-tech, which concentrated much more on fundamentals - the only job assistance was with a terrible company that built low income apartments, then through the UA...
  17. Replies
    13
    Views
    1,498

    I'm not familiar with those instructors, but if...

    I'm not familiar with those instructors, but if you look at the bottom of the web page it lists the apprenticeship coordinator, phone number, and email. I know Mr. Gregory pretty well. Great guy, but...
  18. Replies
    13
    Views
    1,498

    You could either check out Mid-Florida tech...

    You could either check out Mid-Florida tech and/or UA Local 803. I went to Mid-Florida years ago and then went through the apprenticeship program at the UA. Not sure how Mid-Florida is now, but back...
  19. Replies
    20
    Views
    2,187

    We just tell our guys, if you fall, your fired...

    We just tell our guys, if you fall, your fired before you hit the ground.

    Just kidding - a few years ago we were bought by a very large company. At first their safety requirements seemed...
  20. No arguement here. I have no idea about the work...

    No arguement here. I have no idea about the work in other areas as I mentioned. In this area, work is very slowly getting better. As a company we are half the size we were a few years ago.


    I...
  21. Just speaking from my experience, here. The...

    Just speaking from my experience, here.

    The union is unique in that after 5 years you can be making the same as a "seasoned" tech. That is also a benefit in that you have structured raises. In...
  22. Replies
    21
    Views
    4,955

    I'm not sure about schools in you area, but...

    I'm not sure about schools in you area, but hopefully others will provide some recommendations. I would also recommend the UA apprenticeship. Also check out the local tech schools. I went to a tech...
  23. Thread: ISA Certs

    by smokies
    Replies
    1
    Views
    486

    ISA Certs

    CAP - Certified Automation Professional and
    CCST - Certified Control Systems Technican. Anyone in HVAC have these?

    Just curious. I've been around awhile and never heard of it. Does ISA apply...
  24. Replies
    139
    Views
    7,410

    I can relate some what. Everyone in my family...

    I can relate some what.

    Everyone in my family critized me for not going to college. I have two brothers that went right in after high school. Long story short, I make a better living than both of...
  25. Thread: IT HVAC

    by smokies
    Replies
    11
    Views
    1,258

    I'm assuming your referring to Data Centers....

    I'm assuming your referring to Data Centers. Great work down here, we do some pretty large ones. Do alot right for a local cable company right now. Mission Critical type stuff. Every part of the...