02-26-2013, 05:26 PM
- Replies
- 6
- Views
- 507
The T-stat was wired correctly. Called the...
The T-stat was wired correctly. Called the manufacturers tech support to help troubleshoot the problem since this was the first one of these wifi t-stat that I have seen outside of the This Old...
-
02-26-2013, 01:33 PM
- Replies
- 6
- Views
- 507
Nest thermostat and static electricity
Ran into one of the new Nest thermostats last Friday. The customer said his AC would not shut off. Found that he had touched the T-stat after walking across new carpet and zapped it with static...
-
12-20-2012, 09:51 AM
Thread: Hiel H9mpd075
by hvacmontana- Replies
- 18
- Views
- 712
You are right I should have started at the...
You are right I should have started at the begining. The inducer had been installed by another service tech (who is no longer doing service work), about a month before I was called. This was...
-
12-19-2012, 09:59 AM
Thread: First Lenox Pulse 21 Gas Furnace
by hvacmontana- Replies
- 32
- Views
- 2,265
The pulse furnace is pretty much obsolete. ...
The pulse furnace is pretty much obsolete. Lennox no longer supports most parts. The ignition control has always been a problem and there is an after market replacement avaiable from Johnstone...
-
12-19-2012, 09:47 AM
- Replies
- 12
- Views
- 1,244
Code requires the heating circuits to be fused at...
Code requires the heating circuits to be fused at 125% of load, this calls for 30amp protection for each 5 KW of heating element.
-
12-18-2012, 11:28 PM
Thread: Hiel H9mpd075
by hvacmontana- Replies
- 18
- Views
- 712
Thanks for all your suggestions. So far the only...
Thanks for all your suggestions. So far the only thing I haven't tried is the combustion analyser, didn't have it in the van. Yes it does have the dumb valve, I hate those things. I'v replaced...
-
12-18-2012, 08:59 PM
Thread: Hiel H9mpd075
by hvacmontana- Replies
- 18
- Views
- 712
The inducer for this furnace has the proper size...
The inducer for this furnace has the proper size inlet for the model. I checked to be sure the correct inducer was installed because each BTU size requires a specific inducer. Checked the burner...
-
12-18-2012, 08:45 PM
Thread: Hiel H9mpd075
by hvacmontana- Replies
- 18
- Views
- 712
Has a new inducer assy. and the pr switch closes...
Has a new inducer assy. and the pr switch closes no problem.
-
12-18-2012, 08:37 PM
Thread: roll-out tripping!
by hvacmontana- Replies
- 42
- Views
- 3,665
Roll out switch tripping on the H9mpd series...
Roll out switch tripping on the H9mpd series furnaces is usually the result of a problem with the secondary heat exchanger. There was a problem with the oil used when the heat exchanger was formed. ...
-
12-18-2012, 08:07 PM
Thread: Hiel H9mpd075
by hvacmontana- Replies
- 18
- Views
- 712
Hiel H9mpd075
I ran into a problem with a H9mpd075 furnace today that has me stumped. The burners ignite inside the burner tubes about .75 inches in front of the orifices, they burn there for about 30 seconds...
-
04-10-2009, 08:42 PM
Thread: Loop Sizing
by hvacmontana- Replies
- 3
- Views
- 741
A very basic rule of thumb would be 500' of pipe...
A very basic rule of thumb would be 500' of pipe in an extended slinky laying flat in a trench 8' deep for each ton of heat pump capacity. Space between loops at least 2'-3'. A 4ton system would...
-
04-10-2009, 08:22 PM
- Replies
- 21
- Views
- 866
If the furnaceis dual certified then a single...
If the furnaceis dual certified then a single pipe system is allowed but when the furnace is running it is sucking air you have spent money to heat and using it for combustion, where a two pipe...
-
04-10-2009, 07:54 PM
Thread: Confused about furnace suggestions
by hvacmontana- Replies
- 28
- Views
- 2,077
You have my sympathy. From what I have read you...
You have my sympathy. From what I have read you have a perfect example of how not to install a heating system. a natural draft gas furnace in a closet off a bathroom (would never be allowed here)...
-
07-12-2004, 09:16 PM
Thread: POOL-COM-PAK
by hvacmontana- Replies
- 4
- Views
- 1,493
I'm having problems with a POOL-COM-PAK...
I'm having problems with a POOL-COM-PAK dehumidifier system. It runs fine for up to 2 days then the whole unit shuts down and the TD-2000 control panel goes blank. After 1 to 4 hours it starts back...