Search:

Type: Posts; User: lonboy

Page 1 of 18 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: VVT Questions

    by lonboy
    Replies
    3
    Views
    290

    install a barometric damper and dump the excess...

    install a barometric damper and dump the excess air into a hallway or warehouse.
    use average zone terminal load to enable heat or cool
    use a pid to cycle heat or cool to maintain a terminal load...
  2. Replies
    45
    Views
    2,441

    i guess I'm one of those derelicts. Haven't...

    i guess I'm one of those derelicts. Haven't posted here in a while as i've been busy overcomplicating buildings.

    I don't know much about Backnet and don't care to learn. I do know a little about...
  3. Replies
    4
    Views
    588

    In your LNS machine the resource files are in the...

    In your LNS machine the resource files are in the C:/Lonworks/Types folder
  4. Replies
    4
    Views
    588

    From page 132 of the SmartServer user guide.... ...

    From page 132 of the SmartServer user guide....

    If the devices on you network have user-defined network variable types (UNVTs) or user-defined
    configuration property types (UCPTs), copy the...
  5. Replies
    4
    Views
    588

    I really dislike those distech numeric variables....

    I really dislike those distech numeric variables. They are non-standard type and a real pita to deal with.
    Make sure you've loaded the Distech resource files into the smart server. Then you should...
  6. Replies
    4
    Views
    350

    if you have an iLON - create a translator...

    if you have an iLON - create a translator function block and rule to convert a nvoUnitStatus_cooloutput network variable type to an output network variable type of SNVT_HVAC_STATUS.
  7. Replies
    0
    Views
    308

    LON TRAIN RUNNING FEBRUARY IN SO CAL

    Are you ready to learn how to deploy the standard for interoperable multi-vendor building controls?

    Discover how to create and manage multi-vendor control networks by attending a ´hands-on´...
  8. Replies
    29
    Views
    2,241

    plus my vfd with a lon card and an lon internet...

    plus my vfd with a lon card and an lon internet server!
  9. Replies
    29
    Views
    2,241

    just give me a standard thermostat interface, a...

    just give me a standard thermostat interface, a lon programmable, and a couple dewpoint transmitters
  10. Replies
    21
    Views
    1,339

    what do control techs eat?

    how lucky we are as field techs to experience such a wide variety of culinary art in our travels.

    today it was a canadian bacon breakfast at country folks in sepulveda , a double chili...
  11. Thread: Lon Bind

    by lonboy
    Replies
    9
    Views
    596

    if you're using lonmaker you can create visio...

    if you're using lonmaker you can create visio custom properties for connection shapes and define fields for things like source, destination, pkts per second, message type, pkts per transaction, etc. ...
  12. Replies
    7
    Views
    1,336

    wasn't life so much simpler back in the LON days?...

    wasn't life so much simpler back in the LON days?
    lb
  13. Replies
    8
    Views
    1,030

    forget osa/ra enthalpy comparison for economizer...

    forget osa/ra enthalpy comparison for economizer control

    small difference in rh/temp accuracy equals large energy/capacity loss

    better to use dewpoint transmitter from rotronics or airtest
    ...
  14. Replies
    3
    Views
    374

    building automation - system integration with...

    building automation - system integration with open protocols

    http://www.enerlon.com/?page_id=979
  15. Replies
    10
    Views
    630

    Yes, they are alive and well now under a new name...

    Yes, they are alive and well now under a new name - Efficient Building Automation Company EBAC - www.circon.com
    Excellent products, support, and pricing.
    Fraser Newton is the sales guy and Mikey is...
  16. Replies
    0
    Views
    302

    LON Training Running

    Are you ready to learn how to deploy the dark side of building controls?

    Discover how to create and manage multi-vendor control networks by attending a ´hands-on´ LonWorks technology training...
  17. Replies
    30
    Views
    3,772

    i hear that. my escapes also involve a 450 KTM -...

    i hear that. my escapes also involve a 450 KTM - but mine has no front brake and only turns left!

    seems like there are a lot of ac mechs who ride the 2 wheeled off road death machines! might make...
  18. Replies
    30
    Views
    3,772

    now that's funny - don't care who you are! ...

    now that's funny - don't care who you are!

    Wish I could take a vacation. Never taken more than a long weekend in my 58 years. And even then had to put out some fires from the river campground over...
  19. Replies
    30
    Views
    3,772

    I can't tell ya how many times I've had to...

    I can't tell ya how many times I've had to connect and overide some setpoint in between the heat race and the main. I look forward to the day when all I need to carry is my iPhone.
    cheers,
    lb
  20. Replies
    17
    Views
    1,242

    I discovered the dates I booked the Motel6 were...

    I discovered the dates I booked the Motel6 were wrong and found there are no available hotel rooms in Dallas - I found website where I booked a guest room at a local home owned by Paige for half the...
  21. Thread: First Bacnet

    by lonboy
    Replies
    47
    Views
    3,426

    Oh and let's not forget ft10 speed and...

    Oh and let's not forget ft10 speed and through-put also vastly superior to ms/tp
  22. Thread: First Bacnet

    by lonboy
    Replies
    47
    Views
    3,426

    Ya, i limit my control networks to fewer issues....

    Ya, i limit my control networks to fewer issues.
    Plus free topology, noise immunity, and way longer segment lengths
    You wanna have a wager?
    Ft10 vs ms/tp?

    You must love Backnet time and...
  23. Thread: First Bacnet

    by lonboy
    Replies
    47
    Views
    3,426

    Sorry to hijack your thread but I couldn't...

    Sorry to hijack your thread but I couldn't resist...

    Ft-10 is polarity insensitive = electrician friendly! Us Lonboys don't have these issues.

    No way would I ever consider an archaic...
  24. Thread: AHR Roll Call

    by lonboy
    Replies
    7
    Views
    3,481

    Nodes, Shall the control junkies congregate in...

    Nodes,
    Shall the control junkies congregate in Chicago?
    I propose a beer to beer architecture to examine open protocols.
    Cheers
    Lb
  25. Replies
    21
    Views
    1,877

    Why don't you call your local ALC vendor for...

    Why don't you call your local ALC vendor for support?
    lb
Results 1 to 25 of 445
Page 1 of 18 1 2 3 4