  1. Replies
    6
    Views
    174

    I would go with filter in the return air grille....

    I would go with filter in the return air grille. Won't effect the efficiency.
  2. Replies
    9
    Views
    351

    That's just plain lazy. Loops are not good. Have...

    That's just plain lazy. Loops are not good. Have him install it the correct way.
  3. Thread: YJ Scale

    by JES
    Replies
    4
    Views
    221

    Thanks Guys! I really appreciate the help.

    Thanks Guys! I really appreciate the help.
  4. Thread: YJ Scale

    by JES
    Replies
    4
    Views
    221

    YJ Scale

    I have a Yellow Jacket scale, model number 68802. Can I buy just the hand held part? The battery wires came off the curcuit board. I can't tell where to solder them to.
  5. Replies
    7
    Views
    221

    It's a 4 ton unit. Was a load calculation done by...

    It's a 4 ton unit. Was a load calculation done by the 3 companies?
  6. Have them come back and check the subcooling. I...

    Have them come back and check the subcooling. I bet it's under charged.
  7. Thread: XL20i noise

    by JES
    Replies
    34
    Views
    1,372

    The fan looks like it's not spinning fast enough.

    The fan looks like it's not spinning fast enough.
  8. I would give it some time to dry. Maybe you'll...

    I would give it some time to dry. Maybe you'll get lucky.
  9. Best way to test it would be to turn it on in the...

    Best way to test it would be to turn it on in the morning. Don't wait till it's 81* inside.
  10. If your return is making noise, it's to small....

    If your return is making noise, it's to small. Have a pro take a look at it.
  11. Replies
    5
    Views
    387

    Did he make sure the air handler was level?

    Did he make sure the air handler was level?
  12. Thread: Heat Pump in CT

    by JES
    Replies
    5
    Views
    251

    32k btu in CT? What is the sq ft?

    32k btu in CT? What is the sq ft?
  13. Replies
    9
    Views
    378

    I would not open a system to replace the...

    I would not open a system to replace the insulation.
  14. Replies
    7
    Views
    257

    As long as the RA is the right size you should...

    As long as the RA is the right size you should not have a noise problem. Doesn't matter if you use 1 large or 2 smaller ones.
  15. Replies
    4
    Views
    376

    In heat mode you need to take temp inside close...

    In heat mode you need to take temp inside close to the coil for subcooling.
  16. Replies
    50
    Views
    3,719

    Hour and halft to find the tranformer........

    Hour and halft to find the tranformer........
  17. Have a pro come out and find the leak or you will...

    Have a pro come out and find the leak or you will be topping it off every summer. Sounds like it's going into defrost mode.
  18. Replies
    21
    Views
    1,410

    Don't discount the insulation idea. You have...

    Don't discount the insulation idea. You have 4500 less btu's now. The added insulation might be what you need.
  19. If the system has been working good for a 1.5...

    If the system has been working good for a 1.5 years with no one opening the the system....no contaminants. Call some one else.
  20. Call a differant company.

    Call a differant company.
  21. It could be the indoor txv is not bypassing...

    It could be the indoor txv is not bypassing corectly ...blockage?
  22. If the outdoor txv is not opening you should see...

    If the outdoor txv is not opening you should see low suction. What is the suction pressure? make sure you are on true suction.
  23. Thread: blower question

    by JES
    Replies
    7
    Views
    453

    Sounds like the stat is bad .

    Sounds like the stat is bad .
  24. Replies
    20
    Views
    839

    It is possible the return is sucking the basement...

    It is possible the return is sucking the basement smell in. Have someone come out and seal the return duct and find out where the smell is coming from. Don't worry about the pan-joisted return.
  25. Replies
    3
    Views
    450

    Have the tech check the defrost thermostat.

    Have the tech check the defrost thermostat.