  1. the wifi stat is called intesis you can see more...

    the wifi stat is called intesis you can see more at www.intesishome.com
  2. Replies
    36
    Views
    2,498

    yes, do not give up just try to be more thorough...

    yes, do not give up just try to be more thorough when doing your job do not get in a hurry and double check things before starting it up after a repair. most of all becarful and dont get hurt.
  3. Replies
    0
    Views
    187

    york manual forycuz330

    looking for a manual or info for an old york unit ycuz330d3-46pa s/nmgm000783
  4. some old trane wshp's had filter driers in them...

    some old trane wshp's had filter driers in them from the factory in the liquid line in cooling mode. climatemaster, carrier(made by climate master) and trane and mcquay all had models that used a...
  5. Replies
    62
    Views
    4,963

    you used to be able to go into western auto and...

    you used to be able to go into western auto and kmart and buy the kit to convert them into air tanks. i actually have 2 fifteen pound cylinders one r12 and one r22.
  6. actually there is an aftermarket one available...

    actually there is an aftermarket one available that one of the supply houses was showing me that is supposed to work with the minit splits but i have not tried it yet so i dont really know much about...
  7. is it a heat pump, straight ac with gas furnace...

    is it a heat pump, straight ac with gas furnace or dual fuel system? but generally if the instructions give guidelines for charging in cool weather which most do i charge it . it only gets...
  8. how do you know that apple doesnt already have a...

    how do you know that apple doesnt already have a way to hack that phone and just doesnt want to turn it over to the govt or let it out that they can hack any of their phones and have chosen to keep...
  9. Replies
    6
    Views
    1,028

    is the rollout switch new?

    is the rollout switch new?
  10. Replies
    6
    Views
    794

    yes

    yes
  11. Replies
    6
    Views
    794

    yes, it will burn up seals and possibly bearings...

    yes, it will burn up seals and possibly bearings depending on design. it is also dangerous to run it with the discharge valve closed.
  12. Replies
    8
    Views
    461

    is the building pressure negative when the dust...

    is the building pressure negative when the dust collection sytem is running is there a make up air unit? it is possible that you are pulling the exhaust gases back into the building thru the flues.
  13. Replies
    7
    Views
    806

    generally when those boards go bad i just replace...

    generally when those boards go bad i just replace them with relays because of the price of the boards and just put a float switch in to replace the single wire sensor. more than likely the board is...
  14. Replies
    7
    Views
    806

    is it a mark VI board and if it is is it the...

    is it a mark VI board and if it is is it the older dc board or ac? are you using a digital t/stat on it?
  15. Replies
    70
    Views
    4,601

    it could be that the tev is partially plugged or...

    it could be that the tev is partially plugged or failing and somebody has "adjusted the charge" to get the pressure up. 345 is high even for a warm box, but superheat would tell you alot along with...
  16. Replies
    2
    Views
    831

    there is an app for that its called ME engineer...

    there is an app for that its called ME engineer and its free it may help but i would check the condensate pump and wiring it may not be pumping correctly and causing the safety switch to open causing...
  17. Replies
    19
    Views
    2,008

    i say let it go it would be like adding...

    i say let it go it would be like adding refrigerant as a trace gas to find a leak
  18. you need to recheck your gauge calibration and...

    you need to recheck your gauge calibration and thermometer calibration because of the numbers you gave would indicate that your evap is acting as a condenser and subcooling liquid.
  19. Replies
    12
    Views
    1,158

    why dont you set the configuration settings back...

    why dont you set the configuration settings back to the correct ones? and replace the sensor that is out or check to see if it has been replaced before and spliced rather than home run back to board....
  20. Replies
    12
    Views
    547

    i'll also add that they are not needed on split...

    i'll also add that they are not needed on split systems either but i'm glad they put them on and charge the units they dont have to do either, they could just put service ports on and sweat the ends...
  21. Replies
    12
    Views
    547

    manufacturers do math differently, cost to...

    manufacturers do math differently, cost to install valve on unit $20 number of units manufactured 5 million cost to manufacturer $100 million , was the valve needed , no, so why spend the 100 million...
  22. my question is if it is a variable speed unit why...

    my question is if it is a variable speed unit why do they need to run it wide open it would modulate based on load if the proper controllers were being used whether it has 1 compressor or 2
  23. Replies
    34
    Views
    3,575

    baldor and some of the other mfgs are building...

    baldor and some of the other mfgs are building the SGRs into the motors now. they are using the Aegis brand, you can go to the aegis website and get info on bearing failures due to shaft induced...
  24. Replies
    7
    Views
    1,823

    that wont work because it looks for current draw...

    that wont work because it looks for current draw and if it doesnt see it it locks out the circuit
  25. Replies
    7
    Views
    1,823

    i dont know of anyway to disable just one...

    i dont know of anyway to disable just one compressor on those
  26. Replies
    11
    Views
    1,491

    is it an intellipak? if so the filter driers are...

    is it an intellipak? if so the filter driers are down the right side behind the first panel in the supply air section of the unit. that is from looking at the end with the compressors,what i usually...
  27. Replies
    13
    Views
    1,989

    as far as i know tattle tales do not work on...

    as far as i know tattle tales do not work on lockout circuits. you will have to find another way to identify the fault.
  28. Replies
    2
    Views
    891

    maybe some kind of vent fan positioned to blow...

    maybe some kind of vent fan positioned to blow air or exhaust air in the well
  29. Thread: 410

    by chillerout1
    Replies
    67
    Views
    4,581

    dont mind 410 but i have noticed a lot of txv...

    dont mind 410 but i have noticed a lot of txv failures with it.
  30. Replies
    90
    Views
    11,715

    well I got the mwssage loud and clear about...

    well I got the mwssage loud and clear about pushing in contactors, was working on a pump that had tripped breaker this was a 5hp pump turned breaker off and then on to reset turned pump on and when...
  31. Thread: Pentane

    by chillerout1
    Replies
    6
    Views
    1,325

    where do you get pentane from? r23 is...

    where do you get pentane from? r23 is triflouromethane and is not flammable according to msds for it . how big is the system ? been awhile since i worked on a cascade system but most are not very...
  32. Replies
    5
    Views
    1,634

    as far as i know there is no way to do that if...

    as far as i know there is no way to do that if one compresor faults out it stops the circiut
  33. Replies
    37
    Views
    4,368

    i know this sounds crazy but what is the temp...

    i know this sounds crazy but what is the temp drop across the drier? possible that it is partially clogged
  34. look at the Entouch tstats i have a school that...

    look at the Entouch tstats i have a school that is using them and they are happy with them, you can also control lighting with the system. just google entouch controls
  35. Replies
    35
    Views
    3,000

    3ph in a residential home is kinda unusual, new...

    3ph in a residential home is kinda unusual, new r22 install? kinda odd too. but if it is a 3 ph and suction is high or even with discharge that tells me something about the compressor operation., but...
  36. Replies
    34
    Views
    3,633

    most manufacturers offer the option of a coated...

    most manufacturers offer the option of a coated evap coil for corrosive enviroments and i have installed coils that were coated by third parties with no problems , i have also worked on special units...
  37. Replies
    13
    Views
    2,242

    have you checked the MA temp sensor? and is this...

    have you checked the MA temp sensor? and is this being used as a CV or VAV unit and what type of control are you using?
  38. Replies
    13
    Views
    2,242

    i asked because most people judge how clean a...

    i asked because most people judge how clean a coil is based on what they can see on the outside rather than split them and see the debris trapped between the coils. buford, that is usually when i...
  39. Replies
    13
    Views
    2,242

    did you split the coils and check between them?

    did you split the coils and check between them?
  40. Replies
    34
    Views
    3,633

    you could check with the manufacturer and see if...

    you could check with the manufacturer and see if they offer a coated coil for that unit , if not you could order an evap coil and send it out to be coated and put it in when the other one fails. or...
  41. Replies
    51
    Views
    5,523

    i assume your main air handlers have only one...

    i assume your main air handlers have only one coil that either hot or cold water passes thru if this is the case you could have two different answers depending on valve arrangement. if you have...
  42. greenlee makes one that does 230v but its kind of...

    greenlee makes one that does 230v but its kind of pricey depending on how fat your wallet is
  43. just a crazy question but where the duct splits...

    just a crazy question but where the duct splits and goes to each room is there a splitter damper there to adjust how much air is directed to each room?
  44. Replies
    49
    Views
    15,275

    what i do is once i have determined correct...

    what i do is once i have determined correct rotation i cut the wires short and put the crimp caps on them that way it will take a definate effort to make the motor go in the wrong direction , you can...
  45. Replies
    52
    Views
    10,872

    i wouldnt redo the flare either i would cut back...

    i wouldnt redo the flare either i would cut back about a foot from the flare then cut out the section of line as needed then swage it and braze it reusing the factory flare
  46. Replies
    5
    Views
    1,884

    relace it .it is probably doing water source...

    relace it .it is probably doing water source heatpumps in the building chances are depending on which tubes are busted better off replacing
  47. Replies
    43
    Views
    6,444

    havent seen a kold draft machine in a very long...

    havent seen a kold draft machine in a very long time they were the biggest pieces of junktoo many moving parts always had to keepe lots of shear pins for the arms that lower the water plate and float...
  48. Replies
    10
    Views
    1,274

    not only no but He!! No too much liability...

    not only no but He!! No too much liability involved if it were to blow up and kill somebody you would be criminally liable and become bubba's girlfriend in prison.
  49. probably just a dirty condenser or bad sensor

    probably just a dirty condenser or bad sensor
  50. Replies
    12
    Views
    1,717

    connect it to the discharge line.

    connect it to the discharge line.