Search:

Type: Posts; User: voleye

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    15
    Views
    752

    Honestly I would go with the contractor you feel...

    Honestly I would go with the contractor you feel will do the best job and the equipment they install. We used York for 20 years, the only problems we had were with the local distributor. There...
  2. Replies
    3
    Views
    541

    We have had them throwing a fault when it drops...

    We have had them throwing a fault when it drops below zero, but not a communication problem before
  3. Replies
    19
    Views
    1,249

    I have used field piece meters since the old...

    I have used field piece meters since the old stick came out many years ago. I have used the SMAN3 for a couple years now and I love it.

    There are a few reasons I carry the digital gauges vrs the...
  4. Replies
    5
    Views
    3,477

    I usually take my favorite commercial BBQ sauce...

    I usually take my favorite commercial BBQ sauce (it differs depending on the type of meat) and kick it up with at least a shot of Jim Beam Devils Cut.
  5. Replies
    48
    Views
    5,030

    Good luck. We wont work for a home warranty...

    Good luck. We wont work for a home warranty program period. If the home owner has a home warranty and they want us to do the work, the home owner will pay us in full and then "try" to get their...
  6. Thread: Just a rant....

    by voleye
    Replies
    7
    Views
    2,100

    We are lucky, We have these guys in our town. ...

    We are lucky, We have these guys in our town. They will custom make anything you need. http://stonerholsters.com/
  7. Replies
    34
    Views
    3,865

    We do not do a lot of boilers, But we do install...

    We do not do a lot of boilers, But we do install a valve between the boiler and expansion tank, BUT we open it and remove the handle, place the handle inside the burner compartment.
  8. Replies
    23
    Views
    4,908

    If they would have used the black flex, you might...

    If they would have used the black flex, you might not have seen it
  9. Replies
    4
    Views
    520

    I have used the Fieldpiece ATC1 and the ATC3 for...

    I have used the Fieldpiece ATC1 and the ATC3 for many years without any problems.
  10. I would pick a good contractor over picking brand...

    I would pick a good contractor over picking brand name of the furnace. I have seen the best furnaces installed wrong and totally useless. I have seen the cheapest furnace installed correctly and...
  11. Replies
    40
    Views
    3,996

    Fluke is very proud of their products. Too...

    Fluke is very proud of their products. Too proud, I have used all different kinds of meters in the past and will only use Field piece now. They are extremely durable.
  12. Replies
    41
    Views
    2,757

    We have used some of the "super seal" as a last...

    We have used some of the "super seal" as a last resort, unit is not worth leak checking, to get maybe a year out of. There is no sense in leak checking a 20+ year old unit that has a small leak. ...
  13. Replies
    27
    Views
    5,075

    loop is too hot. You should probably do pressure...

    loop is too hot. You should probably do pressure in and pressure out to make sure the pumps are actually pumping, if there is a broken shaft the pump will still show amperage but not be pumping. ...
  14. Replies
    16
    Views
    2,205

    Talked with our ICP service rep. I am told its...

    Talked with our ICP service rep. I am told its a Copeland vendor that uses a product as a rust inhibitor, that is clogging up the TXV's. I am also told its not just an ICP problem. That if its a...
  15. Replies
    11
    Views
    2,796

    We had one do that several years ago. It was an...

    We had one do that several years ago. It was an empty building, Luckily the building next door lost part of the roof and the local fire department had the gas shut off to nearby buildings as a...
  16. Replies
    13
    Views
    2,616

    Nice looking job. Climatemaster wants you to use...

    Nice looking job. Climatemaster wants you to use a hose kit from the geo to the pumps, Its already figured in the pump sizing. We have to use purple cleaner here to. It looks bad but that's...
  17. Replies
    0
    Views
    731

    tornado damage from the Xenia 1978 storm

    I wasn't sure where to post this picture I found while looking thru some of the pictures from the 40th anniversary of the tornado. But I wanted to post this picture when I saw it. I did not...
  18. Replies
    32
    Views
    6,305

    My luck the homeowner would say, Well its only a...

    My luck the homeowner would say, Well its only a year old, Its under warranty
    right?
  19. Replies
    29
    Views
    7,618

    I understand the complaint is with the...

    I understand the complaint is with the contractor, but if I had WF literature saying it had a 10 year p&L warranty then I would be dam sure to get a 10 year p&L with it.
  20. Replies
    67
    Views
    7,664

    Sadly there is a lot of homeowners being taken by...

    Sadly there is a lot of homeowners being taken by "contractors" using scare tactics, and condemning furnaces when they are not bad. IMO that's the bad side of running a tech on sales commission. ...
  21. Replies
    67
    Views
    7,664

    Several years ago we had a customer that was...

    Several years ago we had a customer that was starting into dementia. She called every two days like clockwork and said she had no heat. We would stop by and check it. Now checking it meant...
  22. Thread: Slum Lord

    by voleye
    Replies
    30
    Views
    5,264

    I would have suggested that the gas valve be...

    I would have suggested that the gas valve be replaced. If the landlord chose not to, I would have them sign the work order saying that it should be replaced and he is taking responsibility for it. ...
  23. Thread: Sales Tactic

    by voleye
    Replies
    23
    Views
    3,039

    You have to sell yourself, the brand on the box...

    You have to sell yourself, the brand on the box is nice. But there could be multiple dealers with the same name. Pictures before and after installs, Make sure to point out what seems normal to...
  24. Replies
    20
    Views
    2,746

    We had a similar situation this winter. The HSI...

    We had a similar situation this winter. The HSI would glow and not light 4 out of 6 times. Replaced the HSI and it still would not light. Took the burners out and cleaned them, (Propane) and it...
  25. Replies
    48
    Views
    4,686

    I know they are a tad expensive. But they break...

    I know they are a tad expensive. But they break in a day or two, waterproof, and a good solid boot. Redwings 2892 I think is the number. Around $130 but you can find them on sale. They last me...
  26. Thread: Manual J / D

    by voleye
    Replies
    13
    Views
    1,409

    ACCA has a manual on Manual J. That's how I...

    ACCA has a manual on Manual J. That's how I learned it. Well that and dad taught me. Its nice to learn the "science" behind it, but I do everything on a computer program now in minutes
  27. Replies
    52
    Views
    5,468

    We had three of these hanging Chrysler Airtemps...

    We had three of these hanging Chrysler Airtemps in a bowling alley. Unfortunately it closed last year. But they are still there.
  28. Replies
    0
    Views
    339

    White Rodgers Duel fuel question

    We have a heat pump installed last year with propane backup. We have been using the WR touchscreen 1f95-1277 with an outdoor sensor for the balance point to control the system. The balance point...
  29. Replies
    40
    Views
    9,437

    I had no idea that's what those doors were for....

    I had no idea that's what those doors were for....
  30. Replies
    35
    Views
    6,823

    #12 charge it with frezone until its "beer can...

    #12 charge it with frezone until its "beer can cold"
  31. Replies
    24
    Views
    5,146

    I found one of these at the beginning of spring, ...

    I found one of these at the beginning of spring, This customer had pined the bush to the concrete because it looked bad from the pool. Had a blast trying to wash the condenser, and of course the...
  32. We are not allowed to use the flex connectors...

    We are not allowed to use the flex connectors like that either, We can use flex pipe, but the local inspector wants to see at least 3 feet of black iron pipe on the furnace.
  33. Replies
    26
    Views
    6,730

    I have done that in a pinch to get a unit...

    I have done that in a pinch to get a unit running, But never left it like that.
  34. Thread: top 5 brands

    by voleye
    Replies
    30
    Views
    3,691

    ICP ClimateMaster anything but trane ...

    ICP
    ClimateMaster
    anything but trane
    anything but american standard
  35. Replies
    14
    Views
    3,699

    Poll: Yes I did bump the airflow up to 550 CFM per...

    Yes I did bump the airflow up to 550 CFM per ton. It helped a little, but the first stage really dries the house out, I'm not complaining. I don't mind having to add a little humidity to the...
  36. Replies
    14
    Views
    3,699

    Poll: We have the same thing all the time here. If Im...

    We have the same thing all the time here. If Im using electric as the back up I like to size the first stage to do as close to 100% of the cooling load, and try to get the second stage as close to...
  37. A cure for the dog peeing on the condensing unit?

    383981383991
  38. When you look at natural gas prices you have to...

    When you look at natural gas prices you have to look at the future of it. Not just todays price. Who thinks that gas will actually go down in price from here?
  39. Replies
    14
    Views
    5,866

    I have seen them cut and twisted back together,...

    I have seen them cut and twisted back together, but not like that
  40. Replies
    12
    Views
    3,643

    If that was one of those York camo painted units...

    If that was one of those York camo painted units you would never see it
  41. Thread: #10 fuse?

    by voleye
    Replies
    4
    Views
    1,510

    #10 fuse?

    Pulled the disconnect out and sit it aside. Didnt pay attention to it untill picking it back up to put it back in.
  42. Replies
    9
    Views
    3,462

    Here is the thing. If you put 20 HVAC...

    Here is the thing. If you put 20 HVAC contactors in a room and ask whats the best brand name, You might get 10 different names. Some people like Trane, because thats what they sell or use, Some...
  43. Replies
    13
    Views
    1,755

    I went back today just to check the machine out...

    I went back today just to check the machine out and make sure everything is ok. Talked to one of the trustees about the machine, water quality and operation. Sold them a brand new Manitowac...
  44. Replies
    13
    Views
    1,755

    I went back today. Turns out I took a short cut...

    I went back today. Turns out I took a short cut that I should not have. I did change the water filter two weeks ago (Memorial Day actually). So I thought without checking water flow that it was...
  45. Replies
    13
    Views
    1,755

    Scottsman CME456

    The machine is water cooled. We found the first time out there that they had plugged in a small freezer on the same outlet, We removed that and put the machine on a circut of its own.

    When the...
  46. Replies
    30
    Views
    20,094

    Yes its worth it. This is the third summer since...

    Yes its worth it. This is the third summer since I installed mine. I was dealing with a heat pump with oil back up in south western Ohio. Im using 18% less electric and not filling a 275 gallon...
  47. Thread: Instal of Kerr

    by voleye
    Replies
    19
    Views
    3,688

    She whistles a little when she runs

    She whistles a little when she runs
  48. TxTurbo is right I had a 2.5 ton one stage...

    TxTurbo is right

    I had a 2.5 ton one stage cooling, heat pump/fuel oil system and installed a 3 ton Climatemaster last fall. I was keeping the stat on 68 to keep the humidity down to 48 to 52%....
  49. Thread: Easy service

    by voleye
    Replies
    24
    Views
    3,505

    I don get it. I understand thats not the way...

    I don get it. I understand thats not the way 99.9% of us would put it in. But grab a ladder and jump up there and work on them. The little giant ladders we use are perfect for setting them up on...
  50. Replies
    40
    Views
    6,921

    I like to poke a fork into the steaks several...

    I like to poke a fork into the steaks several times. Then cover the bottom of a pan with Jack Daniels. Let them sit in the fridge for 30 minutes and flip them for another 30 minutes. Fire the...
Results 1 to 50 of 420
Page 1 of 9 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards