Search:

Type: Posts; User: marybear

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    41
    Views
    3,347

    For me it varies from about 3 to 6 hours. Depends...

    For me it varies from about 3 to 6 hours. Depends on where the AH is.
  2. Replies
    56
    Views
    4,436

    Every meter has a design inaccuracy. Stop...

    Every meter has a design inaccuracy. Stop overthinking and looking for a problem where there is none. " A dog chasing its own tail".
  3. Replies
    28
    Views
    2,102

    The X3 Lite lists for $1300.00

    The X3 Lite lists for $1300.00
  4. Replies
    14
    Views
    1,621

    My new one is the UEI DTH35. It shows enthalpy.

    My new one is the UEI DTH35. It shows enthalpy.
  5. Replies
    18
    Views
    1,544

    I think the SC-56 gives the most value and it is...

    I think the SC-56 gives the most value and it is designed specifically for HVAC. Make sure whichever one you choose it is true RMS.
  6. Replies
    1,178
    Views
    130,774

    $749 is too much for me. Every employee I...

    $749 is too much for me. Every employee I mentioned it to said it has to be affordable. For a business it may not be an issue.
  7. Replies
    21
    Views
    1,572

    Installed one last week on an A coil. The...

    Installed one last week on an A coil. The manufacturer recommended on the front panel in the middle of the return side.
  8. Replies
    49
    Views
    4,159

    Very pleased with my UEI DL389 true RMS.

    Very pleased with my UEI DL389 true RMS.
  9. Replies
    38
    Views
    7,987

    This week Gemair in Orlando started selling their...

    This week Gemair in Orlando started selling their stuff.
  10. Thread: Fieldpiece

    by marybear
    Replies
    133
    Views
    26,543

    I have a question concerning the SMAN3. On my...

    I have a question concerning the SMAN3. On my third one due to the high side malfunctioning. Any truth to what I have been told about nitrogen causing issues with the sensor(s) ? I have heard about...
  11. Replies
    26
    Views
    4,432

    Learned using 0% and never had any issue with...

    Learned using 0% and never had any issue with copper to copper. Only use 15% for things like RV's & TXV's due to its cost.
  12. Replies
    12
    Views
    2,883

    Best pawn shop deal ?

    Found a new JB DV 200N in Cash America priced at $130 ! Got it home and it works perfectly. Who ever priced it had no idea what they had.
  13. Replies
    11
    Views
    1,623

    According to the story the repairman was not...

    According to the story the repairman was not asked to leave but held at gunpoint in an attempt to keep him from leaving.
  14. Replies
    2
    Views
    676

    Odd compressor replacement problem.

    This was an older SC CU. Replaced the compressor and capacitor. On start up the low side went to around 0psi, high side went to around 50psi and both lines started to freeze up at the CU. Never had...
  15. Replies
    91
    Views
    10,330

    Reading this thread with interest and thinking...

    Reading this thread with interest and thinking from a different angle.Would having a source of fan forced hot air pointed at the evaporator work ? Just a thought.
  16. Replies
    113
    Views
    9,561

    C would be my answer.Only "side work" I do is for...

    C would be my answer.Only "side work" I do is for family.
  17. Replies
    13
    Views
    2,053

    I went.Despite my numerous certifications and 15...

    I went.Despite my numerous certifications and 15 years in the trade it was a waste even going.They told me they were looking to fill 15 service tech positions.

    If any company in the central...
  18. Replies
    62
    Views
    7,994

    Poll: Soft copper 3/8 and under I swage.Anything bigger...

    Soft copper 3/8 and under I swage.Anything bigger and hard drawn copper I use fittings.
  19. Replies
    36
    Views
    70,669

    HP's are not well suited for colder climates....

    HP's are not well suited for colder climates. Below around 32 a HP will not put out that much heat. Makes me wonder why so many get installed in colder climates :confused:
  20. Replies
    3
    Views
    410

    I will have to search for the cutting one but the...

    I will have to search for the cutting one but the swagging one is linktechtj.com.
  21. Replies
    3
    Views
    410

    Oops, I did not notice a thread was already...

    Oops, I did not notice a thread was already started.
  22. Replies
    3
    Views
    410

    2010 AHR Expo Orlando,FL

    Not much different from when I went in 2005. There was some interesting and innovative products. Here are a few.
    > Solar powered ductless mini-splits. During the night and cloudy days they run off...
  23. Replies
    217
    Views
    9,484

    That guy in the video was wrong on so many...

    That guy in the video was wrong on so many levels. He had absolutely no business going out there and acting as "judge, jury & executioner". It is not like a person was being attacked. The police even...
  24. Replies
    62
    Views
    7,994

    Poll: 3/8" and under I swage.Anything over and it is...

    3/8" and under I swage.Anything over and it is quicker and easier to use a coupling.
  25. Replies
    17
    Views
    2,723

    A rosebud tip used up gas too fast with the...

    A rosebud tip used up gas too fast with the little MC tanks. I use a #1 for small pipe and tight spots and a #2 for general use.
  26. Replies
    65
    Views
    4,242

    Duttydutdut, if you do go with a noncompete...

    Duttydutdut, if you do go with a noncompete agreement make sure it does not prevent in any way the employee obtaining work if he or she leaves. A noncompete is to prevent business competition, not...
  27. The reality of it is that no matter how good and...

    The reality of it is that no matter how good and through you are callbacks happen. No human is 100% perfect all the time and neither is equipment.
  28. Replies
    23
    Views
    1,518

    Next time that happens turn right around and...

    Next time that happens turn right around and leave. In situations like that when they have a part which they obtained nothing good will come of it.
  29. Replies
    31
    Views
    6,616

    Where did you get the notion that a backpack is...

    Where did you get the notion that a backpack is "sissy" :confused: I think they would be ideal for when you have to use a ladder.
  30. Replies
    35
    Views
    10,221

    Just like so many other products, including...

    Just like so many other products, including meters by other companies. I really like the white on black display and they do have a 5 year warranty.
  31. Replies
    61
    Views
    6,147

    Unless there is something wrong with the tool...

    Unless there is something wrong with the tool itself it is the operator.
  32. Replies
    28
    Views
    2,951

    I am partial towards Lennox ones.

    I am partial towards Lennox ones.
  33. Replies
    25
    Views
    1,395

    Job #1 is the much better choice.

    Job #1 is the much better choice.
  34. Replies
    32
    Views
    2,693

    Similar thing happened to me.Makes me think how...

    Similar thing happened to me.Makes me think how many employers are using this as an excuse to lower payroll by replacing people like us with the "4 yr total geeks" ?
  35. Replies
    29
    Views
    2,145

    Have you noticed what is going on now ?

    Have you noticed what is going on now ?
  36. Replies
    101
    Views
    7,726

    I read through this entire thread and it made me...

    I read through this entire thread and it made me disappointed with the narrow,ignorant minded stereotyping shown by certain posters.In todays society tattoos are much more accepted by people living...
  37. Replies
    8
    Views
    1,126

    You may have to do what we down in Florida...

    You may have to do what we down in Florida sometimes.Run it into a drywell.
  38. Replies
    75
    Views
    14,902

    This guy was not a tech but a salesman in...

    This guy was not a tech but a salesman in disguise.I will bet anything that if you played along he would have tried to sell you a whole new system.
  39. In this economy I would not be leaving a job that...

    In this economy I would not be leaving a job that pays $20 an hour !
  40. Replies
    27
    Views
    1,908

    My thoughts

    Two people should have had the work done and the system running after 10 hours.I used to do change outs.More importantly,you should have not be left without heat ! It sound like the CU lost its...
  41. Thread: Media Players

    by marybear
    Replies
    4
    Views
    498

    Try J River Media Jukebox 12.I use it.

    Try J River Media Jukebox 12.I use it.
  42. Replies
    97
    Views
    7,772

    Took a look at the link. It looks so cool - I...

    Took a look at the link. It looks so cool - I want one :)
  43. Replies
    3
    Views
    1,077

    Cooper-Atkins MFM300-KIT3

    Anybody else have one.I just got mine today from Florida Cooling for $200.It was the last one.Can not wait to try it out.It was the last one.Apparently someone tried it for a little and returned...
  44. Yes they did.Your system will never function...

    Yes they did.Your system will never function right.You unfortunately found a "bad apple" of a contractor.Sounds
    like their only interest is how much money they can get out of people.
  45. Hi tobnr, I have been doing installs & service...

    Hi tobnr,
    I have been doing installs & service on systems in central FL for 13 years.This contractor is not doing you right.First,never have the CU bigger than the AHU.Second,it is poor pratice to...
  46. Replies
    17
    Views
    5,861

    First and most important he made a very serious...

    First and most important he made a very serious and critical "error" by not also changing the coil/evaporator !!! The components in R410A and R22 systems are not interchangeable.Two different freons...
  47. Replies
    11
    Views
    1,617

    replacing heat pump

    follow swampfox's advice - he is 100% right
  48. Replies
    10
    Views
    3,486

    wire inside ductwork

    running any kind of wire inside ductwork is a big no-no by any standard ! Difficult as it may be you need to find some kind of alternative.Been doing HVAC in new construction (Florida) for 13...
Results 1 to 48 of 231
Page 1 of 5 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards