    Went to m&p class in Cincinnati(Hebron) was very...

    Went to m&p class in Cincinnati(Hebron) was very informative highly recommend it, but 1st day was all there sales pitch, but class did count for all 16 of my nate hours!
  2. Replies
    19
    Views
    1,927

    Neat job! Nothing wrong with goodman/ amana in my...

    Neat job! Nothing wrong with goodman/ amana in my eyes and were a bryant dealer lol.
  3. Replies
    10
    Views
    812

    Have seen this once on Rheem package heatpump,...

    Have seen this once on Rheem package heatpump, compressor was shot fan span at half speed with contacter not pulled in single pole as well
  4. Replies
    4
    Views
    393

    R.j Schuster author,

    R.j Schuster author,
  5. Replies
    4
    Views
    393

    Hilarious book

    Has anyone read (101 ways to suck as an hvac tech)? Just finished it some real good reading I got a kick out of it, thinking of buying ( no ducks in the attic) anyone recommend it?
  6. Replies
    48
    Views
    5,030

    Done some work with them was on hold so long I...

    Done some work with them was on hold so long I had to charge labour that they wouldn't cover!
  7. Just sent my uei dl379 in for warranty...

    Just sent my uei dl379 in for warranty repair/replacement with similar issues, I couldn't get meter to read same mfd twice on same capacitor. And it took extremely long to read capacitance, also...
  8. Yep forgot about that

    Yep forgot about that
  9. For a cooling pm we clean coils change filters if...

    For a cooling pm we clean coils change filters if they elect, check charge, capacitors, contactor, connections, and clean blower wheel if needed
  10. Replies
    36
    Views
    1,623

    Got me interested

    Got me interested
  11. Replies
    15
    Views
    4,138

    Nice vise am thinking about mounting one to a...

    Nice vise am thinking about mounting one to a Reese hitch on van for stubborn gas valves and such any suggestions
  12. Awesome very Innovative, will overheating be an...

    Awesome very Innovative, will overheating be an issue?
  13. Replies
    16
    Views
    686

    Thanks, yea the continued education education...

    Thanks, yea the continued education education classes at my local supply houses are mostly sales pitch, some useful info, learn a lot just from reading others posts on here
  14. Replies
    16
    Views
    686

    thanks, yeah definitely have drive have a wife...

    thanks, yeah definitely have drive have a wife and a son on the way, love what I do and the workday flies by most of the time, wouldn't choose another career field over it, something new and...
  15. Replies
    16
    Views
    686

    Any advice on keeping up with a ever changing...

    Any advice on keeping up with a ever changing trade? I'm three years outta tech school and have seen it evolve already
  16. Replies
    16
    Views
    686

    Works for me, how long you been in the trade?

    Works for me, how long you been in the trade?
  17. Replies
    16
    Views
    686

    Poor choice of words on my behalf, hvac veteran...

    Poor choice of words on my behalf, hvac veteran sounds better
  18. Replies
    16
    Views
    686

    Only as old as you choose to be

    Only as old as you choose to be
  19. Replies
    16
    Views
    686

    Thanks for being a great resource

    I'm On my third year as a service tech and realize that I'll never quit learning, love this career feild.This site has been helpful in many ways. Thanks. Any tips from old timers are appreciated!
  20. Replies
    15
    Views
    2,489

    Oh I believe you have held my breath in fear of...

    Oh I believe you have held my breath in fear of gagging
  21. Replies
    15
    Views
    2,489

    I love the calls where the customer knows more...

    I love the calls where the customer knows more than tech proceeds to instruct tech lol, fun to prove said customer wrong, and then the calls where you feel like u need Tyvek suit to enter home animal...
  22. Replies
    9
    Views
    1,377

    Have installed hundreds of pro one stats 701, 721...

    Have installed hundreds of pro one stats 701, 721 and 855s very good stats low failure rates good warranty and ease of use for customers, highly recommend the brand
  23. Replies
    49
    Views
    11,138

    I'm guilty of this I'll admit I have left many...

    I'm guilty of this I'll admit I have left many tripsavers like this oops
  24. Replies
    5
    Views
    1,186

    eBay search cbi hvac tools I think northway inc...

    eBay search cbi hvac tools I think northway inc is seller I got ball valve 3 foot hoses for 30 gave them a shot
  25. Replies
    5
    Views
    1,186

    cheap hoses on eBay

    has anyone bought any cbi hoses off eBay I bought a 36 in set ball valve hoses and so far no prob other than gasket too big, replaced gasket and used hoses pulled vac on system and held vac, anyone...
  26. Replies
    11
    Views
    2,640

    Awesome

    Awesome
  27. Replies
    28
    Views
    2,549

    would havehad pee down both legs! and sprayed...

    would havehad pee down both legs! and sprayed that sucker with coil cleaner
  28. Replies
    14
    Views
    3,531

    yes me too the connex stat is awesome enjoying...

    yes me too the connex stat is awesome enjoying the four wire hookup throughout, the evolution extremes are pretty rad
  29. Replies
    14
    Views
    3,531

    nice install the infinity is same as bryant...

    nice install the infinity is same as bryant evolution correct?
  30. take temp readings on both sides of said dryers...

    take temp readings on both sides of said dryers that will tell you if its restricted
  31. Replies
    12
    Views
    570

    ive got fieldpiece pocket psycrometer little...

    ive got fieldpiece pocket psycrometer little silver pen looking deal not sur model #
  32. Replies
    12
    Views
    983

    check strainer before txv, seems the txv is...

    check strainer before txv, seems the txv is responding to temp changes on the bulb
  33. Replies
    12
    Views
    570

    thanks, my readings dont add up then think my...

    thanks, my readings dont add up then think my psycrometer might be off
  34. Replies
    0
    Views
    288

    friday the 13th yep

    rough one today spent two hours this morning chasing a restriction factory strainer in condenser, overlooked by me several times, then clean an service call with 2014s dirtiest evap winner on gaspack...
  35. Replies
    12
    Views
    570

    oh crap thats a bit much lol, what does WB really...

    oh crap thats a bit much lol, what does WB really tell me is 62 WB humid at 76*DB im really not sure
  36. Replies
    5
    Views
    566

    11 requirednindoor txv subcool as per unit data...

    11 requirednindoor txv subcool as per unit data plate i had 18 *sc nd 18* SC 21* temp drop but r22suction sat temp 36 and suction line temp54 im really thinking poor airflow
  37. Replies
    5
    Views
    566

    just wandering if txv systems should gennerally...

    just wandering if txv systems should gennerally follow target sh formulas or not because ive always heard to pay attention mostly to sc on txv systems
  38. Replies
    5
    Views
    566

    was a poor cooling preformance service call, unit...

    was a poor cooling preformance service call, unit seemed undersized 3ton unit on older 2200 sq ft double wide with addition, sh seemed a little high but so did sc both around 18 to 20 so didnt want...
  39. Replies
    12
    Views
    570

    understanding Wetbulb temperature

    is there a formula to calculate humidity using WB and DB temps for example 76DB and 62WB this house felt humid
  40. Replies
    5
    Views
    566

    target superheat with txv system

    Have a dumb question should a TXV system follow the target superheat as per formula, i took WB and Db temps and using my sman3s came up with a 6.7 target superheat but system running at 18 sh, does...
  41. fieldpiece hs36 best allaround i think

    fieldpiece hs36 best allaround i think
  42. Replies
    20
    Views
    1,966

    1 gallon shop vac pain in butt if pan is full

    1 gallon shop vac pain in butt if pan is full
  43. have inificon techmate finds leaks pretty well...

    have inificon techmate finds leaks pretty well and is not too pricy just be sure to have spare senors {diodes) whatever you call thm
  44. Replies
    11
    Views
    1,331

    Check rollout

    Check rollout
  45. check all the way to panel

    check all the way to panel
  46. check your grounds ive had weak grounding cause...

    check your grounds ive had weak grounding cause wierd issues with flame sense
  47. Thread: Magic Trap

    by mdtoon16328
    Replies
    9
    Views
    1,948

    lol looks like they gotta little crazy with the...

    lol looks like they gotta little crazy with the primer/glue on vents as well
  48. Replies
    21
    Views
    4,810

    across from wky publishing, next to lynx?

    across from wky publishing, next to lynx?
  49. Replies
    21
    Views
    4,810

    new building van gaurd sighn out front, nursing...

    new building van gaurd sighn out front, nursing home?
  50. Replies
    21
    Views
    4,810

    nice install what building is this?