  1. Replies
    9
    Views
    442

    I'm confused, how did you know it was over...

    I'm confused, how did you know it was over charged if you at first you could not get a true reading on your pressures because of the shrader valves?
  2. Replies
    52
    Views
    3,815

    Worked on a walk in cooler at an old poultry...

    Worked on a walk in cooler at an old poultry farm...belt driven compressor...written in the concrete pad it was bolted to was..installed Aug 1942...still running today....
  3. Replies
    8
    Views
    1,573

    This unit isn't on an extension cord or anything...

    This unit isn't on an extension cord or anything like that is it?? that will create a voltage drop...
  4. Put a little pipe dope on the tapered...

    Put a little pipe dope on the tapered threads...helps guarantee no leaks...
  5. Replies
    14
    Views
    2,423

    .80 is a little low ..Does this unit have a high...

    .80 is a little low ..Does this unit have a high voltage diode? it is on the output side of the cap to the frame of the microwave?...i would be looking at that...it only allows voltage one way..if it...
  6. Replies
    14
    Views
    2,423

    Did you meter the capacitor? if it is good . get...

    Did you meter the capacitor? if it is good . get a megometer and check the high voltage diode...(rectifier) if bad replace. good luck Joseph....
  7. Replies
    7
    Views
    2,230

    Did ya notice the low side pressure switch hooked...

    Did ya notice the low side pressure switch hooked to the high side just past the drier?? lol what a pudding head this guy was.
  8. Replies
    7
    Views
    2,230

    Got a call on a cooler

    I got a call the other day from a customer who was having problems with there fridge guy . He has been there two days and can't get the cooler to work!
    Hmm didn't take long to figure out why, lol....
  9. Hi coldandpeeved, Is the pilot actually lighting...

    Hi coldandpeeved, Is the pilot actually lighting as you are pressing the ignitor in?
    If so and then it goes out it is not proving flame..if it is not lighting and you are sure that there is plenty...
  10. Replies
    33
    Views
    1,715

    I feel your pain lol. I have been doing...

    I feel your pain lol. I have been doing commercial kitchens now for 6 years.
    I have had a few customers B@tch and complain. I just tell them YOU called me I did not call you...if you want me to...
  11. Replies
    117
    Views
    7,435

    Wow who ever wrote this is a moron..lol..1....

    Wow who ever wrote this is a moron..lol..1. Thinks their s#$t don't stink
    2.Thinks they are a great Businessman lol and 3.prob Has no employees....and if has employees..wow callbacks must be a...
  12. Replies
    26
    Views
    5,204

    Hey tbart what do you mean by won't lite? is it...

    Hey tbart what do you mean by won't lite? is it sparking? and are you sure gas is flowing? a little more info would be helpful....
    cheers
  13. Replies
    16
    Views
    5,660

    Hi iraq usually when a frymaster fryer screams...

    Hi iraq usually when a frymaster fryer screams Help it means the High limit is open..if this is happening periodicly i would check connections on high limit. if good then it might be cycling on the...
  14. Wow this confused me at first as i could not...

    Wow this confused me at first as i could not understand how he pumped down a system he thought had a restricted drier...the sight glass would be your friend there..then i could not understand how the...