Search:

Type: Posts; User: digo

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    3
    Views
    205

    are you sure? maybe try fetching the license from...

    are you sure? maybe try fetching the license from the server. The message tells you you have the require nre core dist available to be installed, but it can't be done without a license upgrade. ...
  2. Thread: Using HTTPS on AX

    by digo
    Replies
    5
    Views
    178

    Read up the prerequisites section in...

    Read up the prerequisites section in docs\docSSL.pdf

    During install, the old crypto.jar is removed from the modules folder. The new module is called platCrypto.jar
  3. Thread: Using HTTPS on AX

    by digo
    Replies
    5
    Views
    178

    which version of AX is running on this customer's...

    which version of AX is running on this customer's site?
  4. Replies
    5
    Views
    198

    The JCE unlimited strength policy files are only...

    The JCE unlimited strength policy files are only required if you're running AX 3.8.

    There are separate policy files for Java 7 and Java 8.
  5. Replies
    4
    Views
    253

    See these threads:...

    See these threads:
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/8811
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/15803
  6. Replies
    8
    Views
    359

    Kele has this transducer... takes a...

    Kele has this transducer... takes a voltage/current input, outputs the resistance. You'd need to order the one with a custom range to match the curve of a 20K ohm sensor....
  7. Replies
    8
    Views
    359

    The 20K ohm sensor is a resistive device. It...

    The 20K ohm sensor is a resistive device. It doesn't send out a signal. Instead, a controller sources a voltage through it to figure out its resistance by measuring the voltage drop. A programmable...
  8. Do you have Rover SP12?

    Do you have Rover SP12?
  9. Replies
    7
    Views
    383

    I have 3 WEB-700 in a large data center, dual Lon...

    I have 3 WEB-700 in a large data center, dual Lon cards in each, MODBUS/TCP and SNMP on another, and MODBUS/RS-485 on another. No issues whatsoever.
  10. Thread: Remote FX Server

    by digo
    Replies
    7
    Views
    513

    I believe tunneling is a feature available on a...

    I believe tunneling is a feature available on a supervisor, I've never tunneled through a JACE. Fox tunneling that is.
  11. I'd ask for clarification, perhaps they could...

    I'd ask for clarification, perhaps they could provide you with an IP rating instead
    http://www.cctvco.com/NEMA-IP-ingress-protection-explained.html
  12. Replies
    2
    Views
    229

    bingo. I know it sucks, but I bet you won't make...

    bingo.
    I know it sucks, but I bet you won't make that mistake again.
  13. Replies
    14
    Views
    598

    So you're pulling in 15 stations into an existing...

    So you're pulling in 15 stations into an existing supervisor, that was not provided and licensed by you. Is that correct? Are they going into fault?
  14. Replies
    14
    Views
    598

    A single JACE

    A single JACE
  15. Replies
    14
    Views
    598

    No device limit

    No device limit
    <feature name="niagaraDriver" expiration="never" virtual="true" schedule.limit="none" point.limit="none" history.limit="none" device.limit="none"/>

    Small building limited to 3...
  16. Replies
    28
    Views
    5,516

    while Mr. bigguy158 stayed in Controls (Green Bay...

    while Mr. bigguy158 stayed in Controls (Green Bay area?) working with big blue, and occasionally going for bike rides? btw, how's the solar setup at the cabin going?
    Indeed google is scary.
  17. Thread: EC BOS ?

    by digo
    Replies
    4
    Views
    223

    Or the sticker under the cover

    Or the sticker under the cover
  18. Thread: EC BOS ?

    by digo
    Replies
    4
    Views
    223

    License Manager, next to hostid

    License Manager, next to hostid
  19. Did you look in the AxCommunity.jar? In the...

    Did you look in the AxCommunity.jar?

    In the math palette they have an AbsTimeOffset object that can be used to subtract a time offset in seconds

    3.6 and newer will automatically convert the...
  20. Replies
    9
    Views
    556

    To clarify, if designed one way or the other it...

    To clarify, if designed one way or the other it shouldn't matter. I'm not advocating running the wheel opposite from the direction the manufacturer intended.
  21. Replies
    9
    Views
    556

    I'd be willing to bet it doesn't matter....

    I'd be willing to bet it doesn't matter. Regardless of the direction the wheel spins, you still achieve the heat exchange/recovery between EA/OA and RA/SA.
  22. See this thread:...

    See this thread:
    http://hvac-talk.com/vbb/showthread.php?1244511-Trane-BCI-C-(BACnet)-UC400-Questions

    Tracer BACnet Setup Tool 3.0:
    http://software.trane.com/GCC/BST.Setup.3.0.74.exe
  23. Yeah, I'd set them to null and not proxy those...

    Yeah, I'd set them to null and not proxy those points.
    TUNCOS is used to ramp the unoccupied setpoint toward the occupied setpoint based on a specific ramp rate. I know with the CVAHU controller...
  24. Use nviTodEvent for scheduled occupancy. I...

    Use nviTodEvent for scheduled occupancy. I believe the nviOccCmd is meant to share occupancy sensors accross multiple VAVs.
    When the wall module is configured with a bypass button, pressing the...
  25. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    3,869

    When I get back to the office on Tuesday I'll...

    When I get back to the office on Tuesday I'll check on the uptime of my WRT54GL and let you know the last time it rebooted. Monthly reboots aren't caused by crappy hardware, they're caused by buggy...
  26. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    3,869

    I guess I haven't bought on of those in a...

    I guess I haven't bought on of those in a while... I agree with you on Belkin. Anything found on the same isle as monster cables at best buy can't be good.
  27. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    3,869

    Linksys was aquired by Cisco long ago. Most would...

    Linksys was aquired by Cisco long ago. Most would agree they're a reputable manufacturer, albeit sometimes the priciest in the enterprise arena. The WRT54GL model was one the best routers in the...
  28. Replies
    4
    Views
    350

    This is old but it explains the sequence in...

    This is old but it explains the sequence in detail: http://support.microsoft.com/kb/124036
  29. Replies
    2
    Views
    342

    Exchange 2013?...

    Exchange 2013?
    http://blog.kloud.com.au/2013/11/22/exchange-2013-dns-settings-cause-transport-services-to-crash/
  30. Replies
    299
    Views
    33,033

    Any protocol at layer 2 (data link layer) is...

    Any protocol at layer 2 (data link layer) is inherently non-routable. ARCnet, ATM, Controller Area Network (CAN), Ethernet, Fiber Distributed Data Interface (FDDI), Frame Relay, LocalTalk,...
  31. Replies
    32
    Views
    4,506

    What up Kirk! So you're saying you don't miss...

    What up Kirk! So you're saying you don't miss working with spudders? [emoji1]
    Hope all is well with you man.
  32. Replies
    32
    Views
    4,506

    wow, if their panel looks like this, imagine the...

    wow, if their panel looks like this, imagine the wire sheet on those spyders... definitely wall of shame contender.
  33. Replies
    1
    Views
    214

    Use the file transfer client to copy it from the...

    Use the file transfer client to copy it from the modules folder in the JACE to your 3.7.106 modules
  34. Thread: AX Histories

    by digo
    Replies
    2
    Views
    373

    Start indicates the time it began collecting,...

    Start indicates the time it began collecting, like after a reboot
  35. Replies
    2
    Views
    504

    Strykers are configurable (ASC), Spyders are...

    Strykers are configurable (ASC), Spyders are fully programmable. Either way, you have to proxy your points and create your own graphic template before duplicating them. Both are licensed products. ...
  36. Assuming you dragged...

    Assuming you dragged WeatherService/WeatherReport/Current to a Px page, change the "tempFont" property to 0.0pt, then use a separate bound label to display your own temperature value.
  37. Yes, it's called fox tunneling.

    Yes, it's called fox tunneling.
  38. Thread: Niagara AX?

    by digo
    Replies
    2
    Views
    385

    Paste special gives you the option to retain...

    Paste special gives you the option to retain existing links
  39. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    450

    Never

    Never
  40. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    450

    Take a picture of it... any chance it's...

    Take a picture of it... any chance it's mislabeled?
    I can see an IDF room having of those CATV signal amplifiers in it. Maybe the 24V transformer is powering the signal amplifier?
  41. Take a look at the property sheet for the...

    Take a look at the property sheet for the LonNetwork, under Monitor you can disable the "Alarm on Failure" property which is a baja:Boolean slot. If you're running 3.6 or newer you shouldn't need a...
  42. Replies
    5
    Views
    703

    ":p" translates to a smiley on the forums :p

    ":p" translates to a smiley on the forums
    :p
  43. Replies
    12
    Views
    561

    Yeah, you're adding a slot, but you're supposed...

    Yeah, you're adding a slot, but you're supposed to edit the facets for the point.
    EDIT: you can get to it from the property sheet
  44. The rule is don't set it any higher than what you...

    The rule is don't set it any higher than what you need. We're talking physical memory here, not disk space. I can't imagine you have that much RAM on this machine. I've never needed to go higher...
  45. niagaraInstallfolder\lib\nre.properties (edit...

    niagaraInstallfolder\lib\nre.properties (edit with notepad while station is stopped)

    java.options=-Xmx256M -XX:MaxPermSize=128M -Dfile.encoding=UTF-8 -Xss256K

    Depending on what version you're...
  46. Replies
    4
    Views
    410

    It appears Honeywell sets these with a...

    It appears Honeywell sets these with a modifyFlag=mfgOnly
    I think these were meant to be modified via either their free LNS plug-in, or the lonhoneywellAXWizards (licensed module) only.
    In AX, the...
  47. Replies
    14
    Views
    1,388

    avoid spaces and dashes in component names, among...

    avoid spaces and dashes in component names, among others

    CTRL + L in workbench, paste this
    module://docUser/doc/aComponentNaming.html
  48. Replies
    4
    Views
    410

    I smell bull****... time to give them a call. ...

    I smell bull****... time to give them a call.

    The flow values you are referring to are stored in the W7751H as SCPTs, (Standard Configuration Properties)
    MinFlow = SCPT 54, offset 8, lenght 2...
  49. Thread: Lon Plug

    by digo
    Replies
    12
    Views
    900

    The ASP043 part number is for the spring clamp...

    The ASP043 part number is for the spring clamp version (SP04302VBNN)
    http://www.onlinecomponents.com/ria-connect-sp04302vbnn.html?p=43130834
  50. Replies
    17
    Views
    1,994

    Sorry guys, I've been MIA (or missing in the...

    Sorry guys, I've been MIA (or missing in the field) for a while.

    Here are the notes I have from the last time I had to set this up.
    Disclaimers: This is not a soup to nuts guide, but contains...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event