Search:

Type: Posts; User: digo

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    3
    Views
    331

    In your Workbench install folder, look in the...

    In your Workbench install folder, look in the docs folder
    \docs\EngNotes\BFormat\docEn_BFormat.pdf
  2. Replies
    4
    Views
    211

    http://hvac-talk.com/vbb/showthread.php?844282-Tra...

    http://hvac-talk.com/vbb/showthread.php?844282-Trane-ReliaTel-BACnet-Controller

    Trane voodo, as usual.

    google BAS-SVP09A-EN
  3. Replies
    12
    Views
    583

    ditto on the Netgear. The latest GS105Ev2 is...

    ditto on the Netgear.
    The latest GS105Ev2 is even cheaper
    http://www.amazon.com/NETGEAR-ProSAFE-GS105Ev2-Gigabit-Managed/dp/B00HGLVZLY

    When compared to the price of the Skorpion from CC, you...
  4. http://lit.daikinapplied.com/bizlit/literature/lit...

    http://lit.daikinapplied.com/bizlit/literature/lit_at_wshp/Catalogs/intro_wshp_mcquay.pdf

    I see a picture of this panel in the pdf above (page 7), this is pre 1986... so you're looking at...
  5. Replies
    3
    Views
    443

    That's what hx profiles have done for years. ...

    That's what hx profiles have done for years. Beware of silver bullet solutions from third parties, your mileage may vary. Certain admin level views require workbench, and not even Niagara 4 has...
  6. Replies
    1
    Views
    269

    Try a OneShot from kitControl. I believe an...

    Try a OneShot from kitControl.
    I believe an action is invoked on either a false to true, or true to false transition

    Scratch that. Here's a post from the niagara community:
  7. Replies
    14
    Views
    1,827

    If you have access to the new niagara-community...

    If you have access to the new niagara-community site, check out this blog article converted over from the old site:...
  8. Creatures of habit, that's all.

    Creatures of habit, that's all.
  9. Anyt converter with an FTDI chipset should do the...

    Anyt converter with an FTDI chipset should do the job just fine.
    http://www.amazon.com/Chipset-Speed-Serial-RS-232-Converter/dp/B005S72HHO

    JACE-2/6
    bps: 115200
    data bits: 8
    parity: None
    stop...
  10. Replies
    8
    Views
    411

    Good, fast, and cheap... Pick...

    Good, fast, and cheap... Pick 2.http://www.aid-n.com/wp-content/uploads/2013/05/AVS-Technology-Breaks-Iron-Triangle-of-Good-Fast-and-Cheap.jpg

    Sent from my XT1058 using Tapatalk
  11. Replies
    6
    Views
    432

    If you can find one... that product is now...

    If you can find one... that product is now obsolete:
    http://www.functionaldevices.com/building-automation/display.php?model=RIBTW2401B-ET
  12. Thread: AX Lon.

    by digo
    Replies
    7
    Views
    298

    Looking in Smart Installer, the latest 3.7.106...

    Looking in Smart Installer, the latest 3.7.106 build from Distech currently shows lonworks.jar to be at revision 3.7.106.3

    At the very least, you should be using this version.
  13. Thread: AX Lon.

    by digo
    Replies
    7
    Views
    298

    Distech does their own voodoo with their BCP...

    Distech does their own voodoo with their BCP Tuning policies, services, etc. I recommend you contact your support channel as they'd know more about it than me.
    I could be a known issue. Also...
  14. Thread: AX Lon.

    by digo
    Replies
    7
    Views
    298

    What does your tuning policy look like? Did you...

    What does your tuning policy look like? Did you change the MaxWrite time property?
    Lon Link Manager view - are all of your links bound?
    What type of Lon devices? Send and receive heartbeat...
  15. Replies
    8
    Views
    635

    I was in the middle of writing that can't be...

    I was in the middle of writing that can't be enough... so I checked the article and where it gives that figure, they hope to save six times that much. Curious if they have been able to even double...
  16. Replies
    4
    Views
    353

    Although they have the same amount of RAM, the ...

    Although they have the same amount of RAM, the JACE 300 has SDRAM, while the JACE 600 has DDR RAM (double data rate)
    By default, max heap is 24MB on the 300 without a license upgrade, whereas the...
  17. Replies
    3
    Views
    874

    5 years later......

    5 years later...
    http://buildingskb.schneider-electric.com/view.php?AID=13414
  18. Replies
    4
    Views
    454

    No, that's the easiest way. You could also...

    No, that's the easiest way.

    You could also make a backup of the entire thing, reinstall the Supervisor software onto a different drive (presumably D: since you appear to have multiple partitions),...
  19. Replies
    4
    Views
    454

    NTFS symbolic link - aka symlink....

    NTFS symbolic link - aka symlink.
    http://www.howtogeek.com/howto/16226/complete-guide-to-symbolic-links-symlinks-on-windows-or-linux/
  20. Thread: Open protocols

    by digo
    Replies
    40
    Views
    4,229

    Unless we're talking about that infamous modbus...

    Unless we're talking about that infamous modbus to BACnet ms/tp gateway :stinks:
    http://hvac-talk.com/vbb/showthread.php?1091701-The-Rage-(because)-of-the-(Gateway)-Machine
  21. Replies
    3
    Views
    403

    Have a look at these:...

    Have a look at these:
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/11645
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/15291
  22. Replies
    74
    Views
    9,855

    Boss was cleaning up the attic here in our...

    Boss was cleaning up the attic here in our office, found this gem. It's headed to a children's museum.
  23. Replies
    17
    Views
    1,128

    The 116 does have LoZ. No mA, but then again,...

    The 116 does have LoZ. No mA, but then again, most current loops I've seen have a 500ohm resistor wired in.


    Sent from my XT1058 using Tapatalk
  24. Replies
    17
    Views
    1,128

    Fluke 116 is what I've used for the last 9 years,...

    Fluke 116 is what I've used for the last 9 years, and I have a separate T5600 amp probe

    Next best is the 117, there's a clamp kit available for that one:...
  25. Replies
    4
    Views
    395

    verify the subnet mask and gateway are correct

    verify the subnet mask and gateway are correct
  26. Replies
    7
    Views
    420

    Spyders are as closed as they get. Both LON and...

    Spyders are as closed as they get. Both LON and BACnet.
    Sure the BACnet version will generate your BACnet points automatically, whereas the LON you have to specify manually, but if you need to...
  27. Replies
    7
    Views
    420

    That is generally true of application specific...

    That is generally true of application specific controllers. Spyders are fully programmable controllers, so if whoever programmed them didn't exposed the data points, you won't be able to get any...
  28. Thread: Microtech 100

    by digo
    Replies
    2
    Views
    578

    RTFM. You should not be changing the leaving...

    RTFM. You should not be changing the leaving water temperature (that is likely a read-only value). Maybe what you're after is the setpoint?
    google CENT1V32.pdf
  29. Replies
    4
    Views
    526

    User-Agent switcher for Chrome:...

    User-Agent switcher for Chrome:
    https://chrome.google.com/webstore/detail/user-agent-switcher/ffhkkpnppgnfaobgihpdblnhmmbodake?hl=en

    Firefox:...
  30. Thread: Niagara Spy

    by digo
    Replies
    2
    Views
    378

    When you right click a host and choose spy, you...

    When you right click a host and choose spy, you can see the title reads "Remote Spy." This is true for local (running on your laptop) or remote stations (like on a JACE or remote Supervisor)
    ...
  31. Replies
    9
    Views
    618

    Good lord, thanks for the memories. I'm so glad I...

    Good lord, thanks for the memories. I'm so glad I haven't touched CARE/SymmetrE in years.
  32. Replies
    9
    Views
    618

    call the contractor who put it in, no one here is...

    call the contractor who put it in, no one here is going to help you
  33. hahahaha I've been called a controls puke and a...

    hahahaha I've been called a controls puke and a keyboard jockey.
    I'm laughing all the way to the bank.
    :putergreet:
  34. Replies
    2
    Views
    370

    Yes. 1931 ≠ 1911

    Yes. 1931 ≠ 1911
  35. Do you have any support from Nagios? I'm...

    Do you have any support from Nagios?

    I'm assuming this is the plugin you're using:
    https://github.com/AndreySV/check_modbus

    Anything useful from running this?

    /check_modbus --help.
    ...
  36. Replies
    3
    Views
    690

    are you sure? maybe try fetching the license from...

    are you sure? maybe try fetching the license from the server. The message tells you you have the require nre core dist available to be installed, but it can't be done without a license upgrade. ...
  37. Thread: Using HTTPS on AX

    by digo
    Replies
    6
    Views
    791

    Read up the prerequisites section in...

    Read up the prerequisites section in docs\docSSL.pdf

    During install, the old crypto.jar is removed from the modules folder. The new module is called platCrypto.jar
  38. Thread: Using HTTPS on AX

    by digo
    Replies
    6
    Views
    791

    which version of AX is running on this customer's...

    which version of AX is running on this customer's site?
  39. Replies
    6
    Views
    1,515

    The JCE unlimited strength policy files are only...

    The JCE unlimited strength policy files are only required if you're running AX 3.8.

    There are separate policy files for Java 7 and Java 8.
  40. Replies
    4
    Views
    773

    See these threads:...

    See these threads:
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/8811
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/15803
  41. Replies
    8
    Views
    963

    Kele has this transducer... takes a...

    Kele has this transducer... takes a voltage/current input, outputs the resistance. You'd need to order the one with a custom range to match the curve of a 20K ohm sensor....
  42. Replies
    8
    Views
    963

    The 20K ohm sensor is a resistive device. It...

    The 20K ohm sensor is a resistive device. It doesn't send out a signal. Instead, a controller sources a voltage through it to figure out its resistance by measuring the voltage drop. A programmable...
  43. Replies
    5
    Views
    1,450

    Do you have Rover SP12?

    Do you have Rover SP12?
  44. Replies
    7
    Views
    878

    I have 3 WEB-700 in a large data center, dual Lon...

    I have 3 WEB-700 in a large data center, dual Lon cards in each, MODBUS/TCP and SNMP on another, and MODBUS/RS-485 on another. No issues whatsoever.
  45. Thread: Remote FX Server

    by digo
    Replies
    7
    Views
    886

    I believe tunneling is a feature available on a...

    I believe tunneling is a feature available on a supervisor, I've never tunneled through a JACE. Fox tunneling that is.
  46. I'd ask for clarification, perhaps they could...

    I'd ask for clarification, perhaps they could provide you with an IP rating instead
    http://www.cctvco.com/NEMA-IP-ingress-protection-explained.html
  47. Replies
    2
    Views
    403

    bingo. I know it sucks, but I bet you won't make...

    bingo.
    I know it sucks, but I bet you won't make that mistake again.
  48. Replies
    14
    Views
    1,265

    So you're pulling in 15 stations into an existing...

    So you're pulling in 15 stations into an existing supervisor, that was not provided and licensed by you. Is that correct? Are they going into fault?
  49. Replies
    14
    Views
    1,265

    A single JACE

    A single JACE
  50. Replies
    14
    Views
    1,265

    No device limit

    No device limit
    <feature name="niagaraDriver" expiration="never" virtual="true" schedule.limit="none" point.limit="none" history.limit="none" device.limit="none"/>

    Small building limited to 3...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365