Search:

Type: Posts; User: Iceman_pdx

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    20
    Views
    1,830

    ECtofix. Yay to bad steam valves ��. Click and...

    ECtofix. Yay to bad steam valves ��. Click and this time I could hear the coils on the valve pull in. yay! We got steam. Happy it's done and the learning experience. Thanks Bro
  2. Replies
    9
    Views
    607

    Shorted scroll 2x

    Hello guys,

    It's Friday and thought I'd come here and get some advice for the pros. I got called to a heat pump system. Another contractor out this system in less than 2 yrs ago. Off brand Carrier...
  3. Replies
    20
    Views
    1,830

    No I haven't descaled a steamer like this. I...

    No I haven't descaled a steamer like this. I pulled the instructions and explains the pump method and adding acid. Lol @ beverage of my choice.
    Another question its got a the electronic touch pad,...
  4. Replies
    20
    Views
    1,830

    Ya fer sure. I can fix anything out there, but...

    Ya fer sure. I can fix anything out there, but hate walking up to a system that I know nothing about and being on a time crunch. It was for a college. I love getting my ass kicked, and the education...
  5. Replies
    20
    Views
    1,830

    I'm good well I hope lol. I already took hoses...

    I'm good well I hope lol. I already took hoses apart after valve and blew thru them. I was looked my for a common factor since both steamers went down at once
  6. Replies
    20
    Views
    1,830

    Just got to steamer. RP device fixed glad to stop...

    Just got to steamer. RP device fixed glad to stop all that water. It's set to operate at 8# and high limit at 15#. I got voltage at steam coil but nothing coming out. I pulled mail steam line and I...
  7. Replies
    10
    Views
    583

    Yes GV in any position. Emailed Nortek. Thanks...

    Yes GV in any position. Emailed Nortek. Thanks DougFamous. Thanks guys. I just have to cover my ass. This contractor is bad and been called out to to much of his stuff. He's getting a new gas valve.
  8. Replies
    20
    Views
    1,830

    To gain access to the boiler I go thru the hand...

    To gain access to the boiler I go thru the hand hole plate? Nut with clamp then pop out steel plate? The inspection plate next to it is for? Replaced that gasket a few weeks ago. Probes have anything...
  9. Replies
    20
    Views
    1,830

    Another thing,I had to fix the RP backflow device...

    Another thing,I had to fix the RP backflow device was shooting out water into floor drain. I sent our plumber over to do it yesterday. Hopefully that is done. Don't know if it's relevant.
  10. Replies
    10
    Views
    583

    I looked at instructions, thanks BaldLoonie....

    I looked at instructions, thanks BaldLoonie. Multi position, but u it could of been flipped to GV not been upside down and unit still could of been horizontal left to right. I have a bad GV on a 2 yr...
  11. Replies
    20
    Views
    1,830

    THANKS ECtofix. I wanna know this steamer from...

    THANKS ECtofix. I wanna know this steamer from start to finish and yes this is a beast. A lot different than a chicksh*t counter model at this point. I may have popped off with the 15# the gage is in...
  12. Replies
    10
    Views
    583

    THANKS Baldoonie. Got it. Thank you. I hear ya...

    THANKS Baldoonie. Got it. Thank you. I hear ya Craig1 �� I hate to blame the equipment, it's not always what you install but how you install it. This installer is bad. You can put the most expensive...
  13. Replies
    20
    Views
    1,830

    I'm mobile so just briefly saw message. Yes gauge...

    I'm mobile so just briefly saw message. Yes gauge says 15# so burners are operating
  14. Replies
    10
    Views
    583

    I know certain brands are less or a lot less than...

    I know certain brands are less or a lot less than other brands but I've never liked blaming the equipment. Consumer reports rates equipment, I tend to rate and blame the installation and installer...
  15. Replies
    20
    Views
    1,830

    Cleveland Steamer help M#36CGM300

    Hello guys. I'm working on Cleveland Steamer and I don't know jack about it. I handle the refrigeration, ovens, freezers, A/C etc etc so I'm apologizing ahead of time. :)

    I've worked on this a few...
  16. Replies
    10
    Views
    583

    Nordyne POS gas furnace question

    Hey guys. There's a local hack, got licensed a couple years ago. I don't usually talk **** but this guys installs are just disgusting, and what's really bad is there brand new homes. I run across a...
  17. Replies
    24
    Views
    1,182

    Sorry guys just got back online. Customer decided...

    Sorry guys just got back online. Customer decided to upgrade to a bigger ice maker so didn't even get to go back. Thanks group
  18. Replies
    15
    Views
    1,204

    Thanks Hellgato. I'll read it this am. I'll look...

    Thanks Hellgato. I'll read it this am. I'll look at that this am trippint. Condenser fan is cycling off in harvest.
  19. Replies
    15
    Views
    1,204

    Manitowoc SY0424A ice won't drop help

    Hey guys. Call today off on error code #2 maximum harvest. Reset went into freeze. Started out 60# end of freeze about 30# normal I think head was about 250# ish. Even ice about 17 min in freeze,...
  20. Replies
    4
    Views
    500

    I have two sets of instructions. The one you were...

    I have two sets of instructions. The one you were looking at then a different one. Different GV and one doesn't have the thermocouple. I added remote control to model # and found different unit. Go...
  21. Replies
    4
    Views
    500

    I meant do you have instructions.

    I meant do you have instructions.
  22. Replies
    4
    Views
    500

    They both look the same. Both look like...

    They both look the same. Both look like thermopiles, both have 2 wires (red & white) that go back to GV. No thermocouple. Just thermopiles pilot line, and the spark igniter. Confused here. Main...
  23. Replies
    4
    Views
    500

    Majestic #RFSDV34 RFN HELP

    Hello guys,

    I need help on this fireplace. I thought the original issue was pilot kept going out but I spoke to tenant for first time today and actually saw unit shut off while running, I had no...
  24. YES it was a spider! LDD we don't see many...

    YES it was a spider!

    LDD we don't see many manufactured house gas furnaces out here. 99% of all manufactured house units are heat pump systems. First time I've seen this gas valve. I just saw a...
  25. Your probably right. Thanks

    Your probably right. Thanks
  26. Direct vent, and I opened up system and added air...

    Direct vent, and I opened up system and added air where gas valve mounts. No change. Natural gas. What's the brass fitting with blue rubber on it?
  27. Help with Coleman manufactured home gas furnace

    Gentleman

    I need help with a manufactured home gas furnace. I don't see to many. Attached pics. System lights, but flame just kind of floats. Stays lit, fan pops on but flames just floats, and no...
  28. Replies
    1
    Views
    433

    Lennox Icomfort thermostat issues

    I have a call on Friday and customer complaining about the IComfort thermostat and constantly losing wi fi connection. From my reading online I guess there is a lot of issues with the wi fi...
  29. Replies
    3
    Views
    700

    Thanks ECtofix

    Thanks ECtofix
  30. Replies
    3
    Views
    700

    YES it's a Perfect Fry too. Lol. Yes I got one of...

    YES it's a Perfect Fry too. Lol. Yes I got one of the connectors to match up but the other one had a few different wires. I kind of wanted to check first, didn't wanna fire the ***** off with the...
  31. Replies
    3
    Views
    700

    Snack mate fryer E box help

    Gentleman,

    Need help on replacing new E control box on this snack mate fryer. I guess snack mate was so,d to whoever, not Pitco took over, or something, I they don't know jack ****. So I got this...
  32. Ya I wondered about the wireless too and touch...

    Ya I wondered about the wireless too and touch screens not available but these jobs were a bid contract bottom line pricing so ain't going wireless.No on the separate shielded wire but we have done a...
  33. I disconnected all low voltage at AH & HP then...

    I disconnected all low voltage at AH & HP then wired in 24v to stat, all good, then wired outdoor sensor in stat started going hay wire. So I left sensor disconnected and wired units in all good. I...
  34. Replies
    0
    Views
    617

    Lifebreath HRV

    Hello all,

    Pew are installing a few Lifebreath HRV units, and wondering if we can run flex duct. Instructions say on the 1200FD/DD model connection sections and shorter runs can be flex must be...
  35. Honeywell 8000/Lennox 5000 stats going bad all possible lines on screen

    Gentleman,

    I'm having another issue with touchscreen stats going bad. Sum take a **** instantly others like yesterday's install lasted all night and this am all possible black lines show up. Last...
  36. Thread: Portland

    by Iceman_pdx
    Replies
    1
    Views
    889

    Portland

    Hello everyone. I hope I'm in the right place. We are a small HVAC/R company in Portland, Or looking for a experienced mechanic for residential/light commercial HVAC work, commercial refrigeration,...
  37. Yes to change Contactor with compressor. My bad...

    Yes to change Contactor with compressor. My bad on that and only takes 1 ass kicking to teach me especially over a ass kicking over a simple fix. I never saw it single phase till this one time, we'll...
  38. Replies
    10
    Views
    1,163

    Yes it's a SC28lx compressor and pressures seemed...

    Yes it's a SC28lx compressor and pressures seemed ok when I got the specs on this the other day but I was planning on getting more info on this thing and was gonna recharge this system and make sure...
  39. Replies
    10
    Views
    1,163

    I know what a CPR valve is and last resort for...

    I know what a CPR valve is and last resort for sure cause it wasn't designed this way and just became a issue. Overloads are correct I ordered them myself. I will dump the charge fear sure. Another...
  40. Replies
    10
    Views
    1,163

    CPR valve?

    CPR valve?
  41. Replies
    10
    Views
    1,163

    Good morning Cracker. What's a corit valve?

    Good morning Cracker. What's a corit valve?
  42. Replies
    10
    Views
    1,163

    Delfield 6000XL help

    PGentleman,

    Delfield freezer M#6151XL-S I looked at this compressor a month ago, replaced bad overload on compressor. Customer called other day, he's been dicking with it apparently when freezer...
  43. So I went back on everything was running �� all...

    So I went back on everything was running �� all this cause contractor was single phasing. Contractor worked fine with previous compressor, and my low voltage is low, and amps seemed higher which had...
  44. I went thru and tightened all connections from...

    I went thru and tightened all connections from panel to compressor on 1st call. Ya low voltage that's what concerns me. Copeland has a range of 184-253 volts so I'm frickin close. Will get that...
  45. I still could have that issue but I'm leaning...

    I still could have that issue but I'm leaning towards contactor but my overload could keep it off as well, but system was off for hours. But my amps did seem high and low voltage so my compressor may...
  46. Mechanical issue on old compressor and ran just...

    Mechanical issue on old compressor and ran just noisy but wasn't throwing breakers. Change compressors, and cooling fine down to -5 degrees but all of a sudden I have a bad contactor too causing unit...
  47. 3 phase semi hermetic shouldn't have this issue I...

    3 phase semi hermetic shouldn't have this issue I was thinking early this am and had contactor in my head. Low voltage, amps seemed high, I was looking at these possible problems and never had other...
  48. No I didn't get a chance to dismantle old...

    No I didn't get a chance to dismantle old compressor unfortunately. It's a flat style heater. Tripped and reset this am and tripped again and got back after lunch and turned on. Wouldn't come on. Fan...
  49. I hate when I have to think lol

    I hate when I have to think lol
  50. I put in defrost yesterday and it doesn't have...

    I put in defrost yesterday and it doesn't have auxiliary contacts, so yes comp and heaters run together for 10 seconds, but it's always been that way and not tripping in defrost or coming out of...
Results 1 to 50 of 235