Search:

Type: Posts; User: snowbird225

Search: Search took 0.01 seconds.

  1. Replies
    55
    Views
    3,093

    Too many variables to trouble shoot over the...

    Too many variables to trouble shoot over the phone, then id say lets get you scheduled for 2 o'clock and have it checked out. they either cancel or go with it.
  2. Thread: add ons

    by snowbird225
    Replies
    2
    Views
    399

    add ons

    What are some add ons you guys like to sell?I like to inform my customers of UV lights, wifi T-stats because i think they are good products, any other products out there that my customers can benefit...
  3. His vents were sweating from poor air flow and...

    His vents were sweating from poor air flow and staining the sheet rock. No elbows on his boxes, ducts were flat. I just simply asked if he wanted me to read run his ducts correctly while I was...
  4. Looks like I'll be running duct in the am lol some of these single runs of 8'' are 50

    688921

    Sent from my SAMSUNG-SM-G920A using Tapatalk
  5. Replies
    8
    Views
    572

    Easy money tho. Cleaned the evap and condenser....

    Easy money tho. Cleaned the evap and condenser. Left with her blowing like a champ

    Sent from my SAMSUNG-SM-G920A using Tapatalk
  6. Replies
    19
    Views
    1,045

    Nu22* Sent from my SAMSUNG-SM-G920A using...

    Nu22*

    Sent from my SAMSUNG-SM-G920A using Tapatalk
  7. Replies
    19
    Views
    1,045

    That's what I was thinking. I was talking to...

    That's what I was thinking. I was talking to another tech yesterday that was saying number 22 can be mixed with R22. Just wondering if you guys tried this

    Sent from my SAMSUNG-SM-G920A using...
  8. Replies
    4
    Views
    519

    I've contacted servolift and multiple supply...

    I've contacted servolift and multiple supply houses. No one can identify the part number. Servolift was bought out so the new owners were no help. I'm goin back tomorrow to look for another part...
  9. Replies
    8
    Views
    572

    she said she was surprised it was that dirty, she...

    she said she was surprised it was that dirty, she just cleaned it off before last summer
  10. Replies
    8
    Views
    572

    shake it off!!

    went on service call yesterday and found a return filter so clogged it looked like plywood. The home owner asked me to use the back door to shake it off lol "ummm mam, I dont think its designed to be...
  11. Replies
    19
    Views
    1,045

    Drop in for R22

    Is there a drop in for R22 that can be mixed with R22 or does this system still need to be evacuated and recharged? Example MO99 or Nu22
  12. Replies
    4
    Views
    519

    servolift heating element (hot well)

    I am working on a hot well SERVOLIFT EASTER MODEL 501-3 208VOLT. I cant seem to find a replacement for the element. the element is spiral and sits in an insulated pad that bolts to the bottom of the...
  13. Replies
    6
    Views
    812

    I see the spring. it looks like you turn the...

    I see the spring. it looks like you turn the screw clockwise it enables the beater to handle more resistance before allowing the swich to move and terminate. I backed the screw out all the way to...
  14. Replies
    6
    Views
    812

    Taylor 432-27

    Been having issues with this machine....
    first i have one hopper freezing product and the other souring. I was trying to get one side running for now as it looks like im only going to have one...
  15. Replies
    27
    Views
    4,562

    I hope so man. That was a real hair puller.

    I hope so man. That was a real hair puller.
  16. Replies
    27
    Views
    4,562

    Yea the freeze stat does break the common. I...

    Yea the freeze stat does break the common. I think that's the only safety that could lock out both compressors. I bi-passed it for now to see if that's it. I changed the belt also. I think it had...
  17. Replies
    27
    Views
    4,562

    Also, I have nothing at x and c.

    Also, I have nothing at x and c.
  18. Replies
    27
    Views
    4,562

    Model 48hjd008u-k54d Serial 63aq-200-501ga ...

    Model 48hjd008u-k54d
    Serial 63aq-200-501ga

    I'm back out with the same issue. I have nothing at my contactors as far as control voltage goes. Condensor fans are running along with blower but...
  19. Replies
    27
    Views
    4,562

    If I push the contactor in it will hold it in. If...

    If I push the contactor in it will hold it in. If I shut the unit off and kick it back on it works fine. Last time this happened I changed the transformer from 40 va to 75. It worked fine for about a...
  20. Replies
    27
    Views
    4,562

    Ems system. It only happens every once in a while...

    Ems system. It only happens every once in a while if I reset the unit it will run fine for about a month or two.
  21. Replies
    27
    Views
    4,562

    carrier rtu on walgreens contactor issues

    I have ran into few carrier units where the contractors are not sucking in all the way. I changed the transformer and a few months later I'm here again facing the issue. Voltage is 208 and I do not...
  22. Replies
    17
    Views
    2,355

    Sounds like an air flow issue. Air could be...

    Sounds like an air flow issue. Air could be restricted making the coil freeze up. This would make a unit sweat.
  23. Replies
    2
    Views
    814

    walk in starving

    I'm working on a walk in with two evap coils on one condensing unit. R22/ suction is 45 /head pressure is 250. Ambient temp is 95. One coil has a 9 degree superheat but the other has about a 20...
  24. Replies
    21
    Views
    3,318

    I thought the same thing. We will find out...

    I thought the same thing. We will find out tomorrow. I have feeling I'll be back out there.
  25. Replies
    21
    Views
    3,318

    fixed

    Another tech went out this morning and eventually found that the condensor fan motor was pulling to many amps. He found the compacitor to be bad. I guess we will find out in the am if that was all it...
  26. Replies
    21
    Views
    3,318

    It is a walgreens.

    It is a walgreens.
  27. Replies
    21
    Views
    3,318

    Shows normal operation on the board. I'll try to...

    Shows normal operation on the board. I'll try to disable the economiser. I just don't see why it works all day and not at night. I take that back I did check the board on the economiser and it...
  28. Replies
    21
    Views
    3,318

    No just a trane tstat

    No just a trane tstat
  29. Replies
    21
    Views
    3,318

    Could the economiser do this

    Could the economiser do this
  30. Replies
    21
    Views
    3,318

    Yes, I go out in the morning and when I get there...

    Yes, I go out in the morning and when I get there it is out on cool fail. So i reset the unit after I look for faults. I was running an 80 psi suction and 255 on the head. (R22) I watched the unit...
  31. Replies
    21
    Views
    3,318

    No the set point is 72. The ambient temp is 85 at...

    No the set point is 72. The ambient temp is 85 at night and 95 during the day.
  32. Replies
    21
    Views
    3,318

    It is a trane tstat. And the temp at night is...

    It is a trane tstat. And the temp at night is about 85 degrees. During the day temp gets to about 95 or so.
  33. Replies
    21
    Views
    3,318

    trane RTU keeps failing

    I have a unit that I cannot find an issue with. Pressures are good, coils are clean but the unit fails over night. Belt was super tight and had black dust on the pully so I changed the belt and check...
Results 1 to 33 of 34