  1. Replies
    41
    Views
    3,046

    Thank You all for the information!!

    Thank You all for the information!!
  2. Replies
    41
    Views
    3,046

    Best Brand of Service Van to Get?

    Hello!
    I am due to get a new service van, and my employer asked me what brand (Chevy, Ford, Dodge, etc.) I wanted.
    I'm not sure which, and don't have any deep preference or alliance to any...
  3. Replies
    11
    Views
    2,040

    Yup

    Yup
  4. Replies
    11
    Views
    2,040

    Gas supply pressure was fine. I should have...

    Gas supply pressure was fine.
    I should have mentioned that in previous post.
  5. Replies
    11
    Views
    2,040

    You're absolutley right, hands. When the gas...

    You're absolutley right, hands.
    When the gas valve was energized, I had -1.3" w.c.---there wasn't enough gas being put out to raise that negative pressure up to -0.2". Tried adjusting gas valve's...
  6. Replies
    11
    Views
    2,040

    Thank You!!

    Thank You!!
  7. Replies
    11
    Views
    2,040

    Thanks Er14ic, I think the diffuser plate was...

    Thanks Er14ic, I think the diffuser plate was clean, but I'll take a nitrogen bottle up with me next visit to be sure.


    No I don't, if the manifold pressure goes from -2.5" w.c. to -1.3" w.c....
  8. Replies
    11
    Views
    2,040

    Trane Voyager RTU Heating Issues

    Hello everybody,
    I got an issue with an older Trane Voyager pack that isn't lighting up in heat.
    The model is YCD150B4LOBA
    The ignitor was bad, so I got a new one, and installed it. On first...
  9. Replies
    20
    Views
    1,767

    A lot of times I use three different methods of...

    A lot of times I use three different methods of leak detection to find a leak. The first is to look for oil stains, or get the general area with a "sniffer". I use an Inficon, and am happy with it....
  10. Replies
    43
    Views
    3,570

    On a couple of maintenance calls I've replaced a...

    On a couple of maintenance calls I've replaced a worn looking thermocouple, telling the customer "this is cheap insurance, it's sure to fail soon". I replace it and now the pilot won't stay lit. The...
  11. Replies
    0
    Views
    968

    Educational VAV Simulator HVAC Site

    Found a cool site that has a simulator of a VAV system. Pretty fancy!
    I downloaded the simulator and tried it out. You can change parameters such as intake air temp and other things and watch how it...
  12. Thanks for the info toolslinger!

    Thanks for the info toolslinger!
  13. Thanks for the site and advice maxster! I have...

    Thanks for the site and advice maxster! I have the site in my favorites, and a binder in my truck.
  14. Mall maps! I'll be scouting for 'em! Thanks!

    Mall maps! I'll be scouting for 'em! Thanks!
  15. Thanks for the site xcel!

    Thanks for the site xcel!
  16. Very good advice! I have a defined line that I...

    Very good advice!
    I have a defined line that I will not cross. I found it good to have that line defined before the situations pop up, that way there's no rationalizations, excuses made, or caving...
  17. I'll definitley keep that in mind Jerry, it would...

    I'll definitley keep that in mind Jerry, it would only be as a last resort. Things weren't looking good there, which caused me to start looking elsewhere in the first place.
  18. Well, I managed to talk to another tech for a...

    Well, I managed to talk to another tech for a while who works at this place too. Come to find out there is a couple of techs who have worked there for over a year. I also asked him if they deliver on...
  19. I'm gettin' it, Timebuilder. It's been a learning...

    I'm gettin' it, Timebuilder. It's been a learning experience.
  20. I think who's getting milked the most is the...

    I think who's getting milked the most is the employees. The more I read the Human Resources legalese in their employment manual, the more I see how things are rigged to legally deny the health and...
  21. Thanks Hungrytech. You're right about...

    Thanks Hungrytech.
    You're right about interviewing the company as well as being interviewed, next time I'm going to dig a little deeper.
  22. Thanks, madhat and timebuilder. Think I'll be...

    Thanks, madhat and timebuilder.
    Think I'll be gettin' the resume back out.
    Just signed up to hvacagent.com.
  23. whoops

    Sorry that paragraph at the bottom of the post---wasn't supposed to be there. Please disregard. I looked for an edit button to get rid of it, guess there isn't one.
  24. Residential tech starts in Commercial-Bad deal?

    Hello all!
    Sorry for the long post, I've tried to make it short as I could.

    I've been a residential HVAC tech for 11 years, working for the same company since I left trade school.
    I'm NATE...
  25. Replies
    17
    Views
    1,483

    Restricted/ collapsed return air duct? I don't...

    Restricted/ collapsed return air duct?

    I don't think I would suspect the reversing valve. If it leaked I think you would have lower head /high suction pressure.

    Dirty filters inside the house? ...
  26. Replies
    28
    Views
    2,026

    You're right, I was thinking of a heat pump only...

    You're right, I was thinking of a heat pump only thermostat. I was under that impression when martyinlincoln said to use emergency heat in the above post.
    If the tstat can be configured to...
  27. Replies
    28
    Views
    2,026

    That would work, but I would be hesitant to do it...

    That would work, but I would be hesitant to do it in a customer's house.

    Somebody in that household (relative, visitor) is going to put that heat pump stat into "Heat" mode. Sure 'nuff--that...
  28. Replies
    28
    Views
    2,026

    I've seen several "cooling only" heat pump set...

    I've seen several "cooling only" heat pump set ups. I agree with Turnbull40 and Rob in WV :
    1. Hook the "O" wire to "R" so a constant 24 volts is going to the reversing valve. This'll prevent a...
  29. Thread: dye

    by chrisnorris
    Replies
    16
    Views
    1,503

    Isolation leak test

    YES! the good ol' isolation leak search. That's exactly what we did to find the "unfindable" leaks on split systems before we started using the dye. Now -a-days, we'll resort to the isolation leak...
  30. Replies
    27
    Views
    2,172

    I've never seen reverse polarity to furnace cause...

    I've never seen reverse polarity to furnace cause an ignitor to glow as soon as it's plugged in, though I've seen plenty of reverse polarity error codes. What always tipped me off that polarity was...
  31. Replies
    38
    Views
    2,986

    I change mine every three evacuations, unless...

    I change mine every three evacuations, unless it's after a compressor burnout or a system that's been open for any length of time. A new drier has been put in too.
  32. Replies
    619
    Views
    113,546

    Dumbest for me was a no heat call, the thermostat...

    Dumbest for me was a no heat call, the thermostat was in "off" position.
    Was also one of the sadder calls I did. Guy was a good customer in his 80's with Alzheimers coming on.
  33. Thread: dye

    by chrisnorris
    Replies
    16
    Views
    1,503

    If I've thoroughly looked over the system with a...

    If I've thoroughly looked over the system with a "sniffer" and an ultrasonic and still can't come up with anything conclusive, I'll use the dye. Our company uses the Spectroline ultraviolet kit.
    I...