    No flame loss false to date

    No flame loss false to date
  2. Replies
    8
    Views
    1,770

    You asked if there are any other faults . Yes the...

    You asked if there are any other faults . Yes the blower fault is first and then ignition lock out and as per engineers this is the proper sequence due to a blower air fault it is not an ignition...
  3. Replies
    8
    Views
    1,770

    2007

    2007
  4. Replies
    8
    Views
    1,770

    Yes and no on the issue . Factory engineers have...

    Yes and no on the issue . Factory engineers have mostly been blaming the inlet gas presssure . The Gas valve they claim has only a 30% tolerance on gas prs. . Had pressure loggers on for months and...
  5. Replies
    3
    Views
    876

    yes all voltages are correct for all phases ,...

    yes all voltages are correct for all phases , unit is wired as well with icm 450 set up for front and back phase inbalance set at 12-15 % if i remember correctly . motor nameplate on both original...
  6. Replies
    3
    Views
    876

    york ypal085e rtu cfm issue

    york swears they have had this 2 hp in use for sometime with out any isuues they are aware of . The original motor p/n# was 02427322005 was 460 volt 1440 rpm at rla of 3.1 . the replacment p/n is...
  7. Replies
    7
    Views
    1,696

    FIRST OFF 300 # NITROGEN IS NOT ENOUGH MANUF....

    FIRST OFF 300 # NITROGEN IS NOT ENOUGH MANUF. WANTS 600# FOR 24 HRS . YOU WILL NEED TO PURCHASE BALL VALVES RATED AT SOME ARE 700 BUT LOOK FOR 800 PSI . AND YES HAVE RAN INTO THIS BEFORE WITH BALL...
  8. Replies
    15
    Views
    1,340

    NO DOUBT FLOOR IS AT DEW POINT AND ALL THE...

    NO DOUBT FLOOR IS AT DEW POINT AND ALL THE MENTIONED SOLUTIONS WERE CORRECT DEHUMID , FRESH AIR ,ODA. ONE THING YOU MAY LOOK INTO IS THE WATER TABLE WERE YOU ARE AT IS WATER WICKING THRU THE CONCRETE...
  9. Replies
    7
    Views
    1,696

    NOT SURE WHAT YOU ARE ASKING ARE YOU ASKING ABOUT...

    NOT SURE WHAT YOU ARE ASKING ARE YOU ASKING ABOUT THE BALL VALVE THAT SHOULD BE INSTALLED AT EACH PORT OR THE SOLENOID VAVES IN THE BC ITSELF .
  10. EXACTLY IF YOU CAN UNDERSTAND A P/T CHART YOU...

    EXACTLY IF YOU CAN UNDERSTAND A P/T CHART YOU COULD ANSWER THIS YOURSELF . HIRE SOMEONE BEFORE YOU KILL THE EQUIPMENT :cheers:
  11. Replies
    8
    Views
    2,123

    YOU DO NOT MENTION THE LENGHT OF THE LINES AND...

    YOU DO NOT MENTION THE LENGHT OF THE LINES AND FITTING ARE FIQURED IN AS WELL. IF TOTAL IS OUT OF LINE THEN THE SIZE SHOULD HAVE BEEN INCREASED AND KEEP IN MIND IF THAT BE THE CASE MAY HAVE BEEN OIL...
  12. Replies
    8
    Views
    1,770

    RAYPAK MVB BOILER

    ANY ONE OUT THERE HAVE ENOUGH BACKGROUND TO GIVE SOME ADVICE ON ERRATIC BY THIS I MEAN BOILER LOCKS OUT ON AIRFLOW ERROR CODE AND WHEN RESET BY ON SITE MAINT. WILL RUN WITHOUT ANY ISSUE AND GO FOR...
  13. IF O/L DOES RESET , YOU CAN CHECK WINDING...

    IF O/L DOES RESET , YOU CAN CHECK WINDING CONDITION WITH A MEGGER AND VERIFY THE INTEGRITY OF THE MOTOR A GENERAL RULE OF THUMB I ONE MEG-OHM /VOLT THIS IS ONLY A GUIDE IF MEG-OHMS ARE ABOVE...
  14. Replies
    39
    Views
    2,655

    verify air flow ,if corrrect cfm ,disable blower...

    verify air flow ,if corrrect cfm ,disable blower and see if distributor tube frost evenly and quickly if not recover refrig. remove txv and lld , blow lines out with nitrogen , put clean txv back in...