Search:

Type: Posts; User: mikey_9

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    659

    Is this that querk where the user needs to be...

    Is this that querk where the user needs to be administrator on the local machine (not a network user)?
  2. Replies
    9
    Views
    1,535

    We make these inhouse. ...

    We make these inhouse.

    http://www.planetcontrols.com.au/products.php?content=crems

    Comes with 4 hour battery backup, 24VDC/AC powered, SMS, Email, SNMP, etc. Not sure how it goes price wise or...
  3. Replies
    39
    Views
    2,982

    Can I bother you for 1 also? :)

    Can I bother you for 1 also? :)
  4. Thread: FX-60

    by mikey_9
    Replies
    12
    Views
    948

    Are you using the NRM? In Oz the NRM is way...

    Are you using the NRM? In Oz the NRM is way expensive ($100AUD +) so I altered the program to take a 1KNi sensor with a push button for After Hrs or a 10K sensor configurable with the MUI.

    It...
  5. Replies
    7
    Views
    609

    I did this the other day..Check out the Help in...

    I did this the other day..Check out the Help in workbench. Its a bit obscure but manageable. :D
  6. Replies
    25
    Views
    1,248

    Man, I thought NAtive BACNET was peer to peer. I...

    Man, I thought NAtive BACNET was peer to peer. I was commenting on this to a Delta Tech and he told me that Delta was P2P. :confused:
  7. Replies
    3
    Views
    396

    You'll need FX builder to configure the program. ...

    You'll need FX builder to configure the program. Setting up the scheduling is very messy.
  8. Thread: AX to Outlook

    by mikey_9
    Replies
    14
    Views
    993

    Why not try to re-educate them into using the...

    Why not try to re-educate them into using the schedule for the room as the reservation system rather than Outlook? :confused:
  9. Replies
    5
    Views
    437

    I'm thinking it should be an enum also...

    I'm thinking it should be an enum also...
  10. Replies
    4
    Views
    2,104

    Thanks heaps. :)

    Thanks heaps.

    :)
  11. Replies
    4
    Views
    2,104

    Thanks

    Thanks
  12. Replies
    4
    Views
    2,104

    Carrier GX30 Chiller Modbus Registers

    I have a Carrier 30GX chiller with a HLI into a Trend XNC. The Trend has died and I have a Jace6 (FX-60) on site. I have been trawling the internet I have found that the chillers came with a RS485...
Results 1 to 12 of 12