  1. Replies
    4
    Views
    107

    I have never had that issue and have worked on...

    I have never had that issue and have worked on many of those including installing the software. Post the version of the software if you can. Considering how old the units are they will not update the...
  2. Replies
    1
    Views
    123

    The NDIO daemon is in the JACE and it...

    The NDIO daemon is in the JACE and it periodically verifies that status of the NDIO. If for any reason if it cant communicate with the NDIO it faults. It may also reboot the JACE if configured to and...
  3. Replies
    21
    Views
    1,488

    It looks level and properly secured whats the...

    It looks level and properly secured whats the problem? :censored: idiots. Now I know why I have such low tolerance for stupidity
  4. Thread: solenoid valve

    by hvac69
    Replies
    10
    Views
    315

    Possibly this...

    Possibly this http://cdn.globalimageserver.com/fetchdocument-rh.aspx?name=rknl-g-75-10-ton-consumer-literature
  5. Thread: solenoid valve

    by hvac69
    Replies
    10
    Views
    315

    I would think reheat for dehumidification. Cant...

    I would think reheat for dehumidification. Cant seem to verify that though by the model number or option code. Possibly their Humid Dry system. Does the unit have a VFD? The upper solenoid looks to...
  6. Thread: Pump DP switch

    by hvac69
    Replies
    9
    Views
    875

    Need some silicone around the cover and tighten...

    Need some silicone around the cover and tighten the screws :)
  7. Replies
    5
    Views
    258

    With the commissioning tool you should be able to...

    With the commissioning tool you should be able to monitor the output of the pmo that drives the physical output and see if they are dropping out together.
  8. Replies
    2
    Views
    307

    Doesnt matter, just need to follow normal network...

    Doesnt matter, just need to follow normal network practices.
  9. Replies
    7
    Views
    308

    The steam converters I have seen over the years...

    The steam converters I have seen over the years had the pneumatic actuators fail closed. 0 psi closed. Trying to identify that control no luck so far
  10. Replies
    16
    Views
    753

    They have hinged doors with latches on the high...

    They have hinged doors with latches on the high pressure side of the supply fan. Imagine an 8 ft door with 2" of duct pressure behind it and you are not expecting it. Usually there are warning...
  11. Replies
    16
    Views
    753

    Have worked on many and they are very common in...

    Have worked on many and they are very common in my area.
  12. Replies
    14
    Views
    425

    Bare bones unit from what I can tell and would...

    Bare bones unit from what I can tell and would agree that the compressor is busted. I would look at flow rates through them.
  13. Replies
    14
    Views
    425

    Model and serial number? Modulating cooling and...

    Model and serial number? Modulating cooling and compressor unloading?
  14. Thread: CSST

    by hvac69
    Replies
    12
    Views
    1,067

    I remember seeing an apartment or condo complex...

    I remember seeing an apartment or condo complex in NE Philadelphia with this running along the entire outside of the building complex and it looked like crap. You could see it from the main road, I...
  15. Thread: CSST

    by hvac69
    Replies
    12
    Views
    1,067

    I always wonder would anything really matter if...

    I always wonder would anything really matter if lightning struck gas pipe, regardless of what it was made of? It rips trees in half.
  16. Replies
    22
    Views
    1,592

    Hey, at least my eyebrows are still there.

    Hey, at least my eyebrows are still there.
  17. Replies
    2
    Views
    224

    Go into properties tab of the schedule, look at...

    Go into properties tab of the schedule, look at the filters and set both for Any Day, Any Month, Any Year. Then save
  18. Replies
    2
    Views
    293

    Weather service is causing it. Disable it then...

    Weather service is causing it. Disable it then reboot. Weather service was changed from HTTP to https and Jace's are throwing a fit
  19. Look at the saturated condenser temp and see if...

    Look at the saturated condenser temp and see if it matches actual
  20. I would think cost of the transducers. I would...

    I would think cost of the transducers. I would assume the calculation is based on PT charts for the refrigerant type that is selected in the control.
  21. From what I remember they calculate it based on...

    From what I remember they calculate it based on outdoor and condenser temps.
  22. Replies
    56
    Views
    4,261

    There should be a trap on the lower coil before...

    There should be a trap on the lower coil before it continues vertically. Usually you will see a inverted trap as well at the top of the vertical riser. With a close coupled system like that it might...
  23. Replies
    56
    Views
    4,261

    Bottom coil is probably full of oil as well. They...

    Bottom coil is probably full of oil as well. They did accomplish a full out WTF though.
  24. Replies
    42
    Views
    1,287

    I seen your reply after I posted. I also made a...

    I seen your reply after I posted. I also made a mistake when considering the subcooling when thinking about the charge. With the superheat that high and subcooling that low you either have a...
  25. Replies
    17
    Views
    1,576

    Use the Ratio block in the palette. Link space...

    Use the Ratio block in the palette. Link space temp to x. x1 would be the low space temp setting input. x2 would be the the high space temp setting. y1 would be the desired discharge air setpoint at...
  26. Replies
    42
    Views
    1,287

    Get the subcooling up and superheat down to...

    Get the subcooling up and superheat down to normal ranges. The evap temps are below freezing.
  27. Replies
    42
    Views
    1,287

    Your numbers indicate 32 degrees of superheat and...

    Your numbers indicate 32 degrees of superheat and 1 degree subcooling. I would be looking at the charge and superheat at each evap.
  28. Replies
    18
    Views
    1,983

    The only thing I have seen guaranteed by permits...

    The only thing I have seen guaranteed by permits is that the local jurisdiction gets its share of the loot.
  29. Replies
    13
    Views
    1,131

    Take the chance if it is something you want....

    Take the chance if it is something you want. Leave on good terms and be honest with your current employer as to why you are leaving.
  30. Replies
    8
    Views
    378

    Has it worked for the last 30 years thinking...

    Has it worked for the last 30 years thinking something was correct at one point? If they are two individual condensers and evaporators stage them.
  31. There should be a tab under the diaphragm of the...

    There should be a tab under the diaphragm of the actuator that you slide.
  32. Replies
    5
    Views
    334

    Had a site where 3 of 5 of their computers that...

    Had a site where 3 of 5 of their computers that accessed 3.8 kept bouncing back to download page, even though the newest version of JAVA was clearly installed. IT dept ended up uninstalling and...
  33. Replies
    15
    Views
    2,297

    Loss of charge safety and still ridiculous no...

    Loss of charge safety and still ridiculous no matter what they call it, even though they usually have higher cut out settings.
  34. Replies
    4
    Views
    263

    Check your private messages

    Check your private messages
  35. Replies
    5
    Views
    490

    The supply and return separated by 6 inches is...

    The supply and return separated by 6 inches is normal for the secondary loop. Still trying to picture the other piping
  36. Under the house shouldn't be any different than...

    Under the house shouldn't be any different than in an attic. Unless the under the house is wet than there is an different issue that needs to be taken care of separately. There are commercial AHUs...
  37. Replies
    23
    Views
    2,345

    Break the source of the 24VAC at the transformer...

    Break the source of the 24VAC at the transformer instead of to the thermostat and the unit will shutdown immediately..
  38. Replies
    8
    Views
    1,528

    Ball valve there so when the cap rots out. Good...

    Ball valve there so when the cap rots out. Good thinking. :grin2:
  39. Replies
    8
    Views
    567

    Same one I am using. I will have to look at the...

    Same one I am using. I will have to look at the driver info when I get a chance.
  40. Replies
    55
    Views
    5,496

    #4 aluminum feeding 100 amp main breaker, feeding...

    #4 aluminum feeding 100 amp main breaker, feeding the bus with #12? Or is that the other way around?
  41. Replies
    8
    Views
    567

    AX will work. As stated the lon adapter should...

    AX will work. As stated the lon adapter should appear in the control panel, plus it should show in the device manager with no error if installed correctly. AX will not work with it if it is not...
  42. Make sure the path is to the png in the px file...

    Make sure the path is to the png in the px file is to the copy of it on the JACE and not to a directory on your computer. Also check the categories and make sure that the other users have the right...
  43. Replies
    11
    Views
    629

    Your thinking is correct, the resistor is...

    Your thinking is correct, the resistor is normally for the Fire panel trouble initiate. In your original drawing they are essentially using the trouble contacts for load control which they normally...
  44. Replies
    19
    Views
    3,127

    They just come back for more.

    They just come back for more.
  45. Replies
    135
    Views
    3,899

    I have thought it many times, but this time the...

    I have thought it many times, but this time the differences between the two are scary. One belongs in a jail and the other possibly institutionalized IMO.
  46. Replies
    135
    Views
    3,899

    You are correct. The outcome of this election...

    You are correct. The outcome of this election scares me. This election looks like it will be truly the lesser of two evils.
  47. Replies
    9
    Views
    626

    I would call the control contractor then.

    I would call the control contractor then.
  48. Replies
    9
    Views
    626

    That is a 24VAC floating control spring return...

    That is a 24VAC floating control spring return actuator. There should be 3 terminals that are used for directional commands. The CCW or CW terminals are used to drive it in the direction you want. ...
  49. Replies
    8
    Views
    478

    Assuming you are referring to a DX9100. From what...

    Assuming you are referring to a DX9100. From what I recall and a quick check the DMO will not be much help. The DMO will show you what the output tag is. For example the DMO will list PID4's output...
  50. Replies
    40
    Views
    1,865

    I agree and what my first post was about. This...

    I agree and what my first post was about. This did go off the rail rather quickly.