  1. Replies
    2
    Views
    404

    Switching to electric

    I will be switching my DHW from a Amtrol boiler mate to a 40 or 50 gal electric hot water heater. I know that the electric heater only needs two pipes (Cold going in and hot coming out). However with...
  2. Motoguy128 I am on oil and that is why I'm...

    Motoguy128 I am on oil and that is why I'm thinking if going electric is better with current price of oil. My other concern is not running the boiler in the summer as folks say the indirect keeps the...
  3. Need to make final decision ASAP HELP!!!

    Indirect water heater or electric water heater. Amtrol boiler mate is leaking bad now. I tried replacing the gasket between the heat exchanger and tank but the thing is still leaking. I have looked...
  4. Replies
    12
    Views
    1,143

    Ok so I'm still dealing with this dilema. I tried...

    Ok so I'm still dealing with this dilema. I tried replacing the gasket between the heat exchanger and tank but the thing is still leaking. I have looked at a Geospring Hybrid electric water heater...
  5. Replies
    12
    Views
    1,143

    @jpsmith Sorry I was in the zone typing and...

    @jpsmith Sorry I was in the zone typing and forgot the rules. :grin2:
  6. Replies
    12
    Views
    1,143

    Indirect or electric

    Ok so my Amtrol 41 gal indirect boiler mate has started to leak from the top at the 6yr mark no longer under warranty. I was told that it has a gasket between the heat exchanger that may be replaced...
  7. Replies
    14
    Views
    1,211

    So when you say in floor heat are you refering to...

    So when you say in floor heat are you refering to radiant subfloor heating systems?
    And you don't think adding a few more registers will make any difference?
  8. Replies
    14
    Views
    1,211

    Do you mean the water temp on the boiler?

    Do you mean the water temp on the boiler?
  9. Replies
    14
    Views
    1,211

    Genduct, I do have a 7' baywindow in the living...

    Genduct, I do have a 7' baywindow in the living room and a 6' full glass french door that opens to the back deck. I'm wondering if its because its such a large open space with high ceilings and only...
  10. Replies
    14
    Views
    1,211

    So can anyone tell me what type of company I s...

    So can anyone tell me what type of company I s hould call for the calc? I would hate to spend money and not get the right info or service. This sux, because there are people and:censored: companies...
  11. Replies
    14
    Views
    1,211

    @ wahoo, basement is not finished. Boiler, air...

    @ wahoo, basement is not finished. Boiler, air handler, washer&dryer down there.
    Recently added r30 batt insulation to joists below and I think it helped a little. But its still not warm enough. The...
  12. Replies
    14
    Views
    1,211

    Thanks for the reply skippedover. As I mentioned...

    Thanks for the reply skippedover. As I mentioned Im new and I'm clearly not an HVAC expert. :gah: I've had a couple of guys come in and they have not been helpful. I see that you are also in MA is...
  13. Replies
    14
    Views
    1,211

    Need some help!!!

    I'm new here and hope that someone can help me figure some things out.
    I have a 28'x30' two story home with 8' 10" ceilings. The house was built about 5 years ago. I have two zones with a oil fired...