  1. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    What exactly is this transmission delay used for....

    What exactly is this transmission delay used for. I have changed it from 0 to 100ms, to 200ms, 250ms, 500ms, 1000ms and have not found any difference.
    Also can you explain what the pollcycle time is...
  2. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    The tech from the Gen company had modscan and he...

    The tech from the Gen company had modscan and he could see the device on the same cable that is installed. He put the bias resistor on at the loytec end and set the bias resistor in the genset...
  3. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    Sorry did you not read the part about where i...

    Sorry did you not read the part about where i have 2 modbus meters reading fine, and if i unplug one then the readings from the unpluged meter come back as damaged.

    Either the generator is no...
  4. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    Frame damaged can mean the device does not...

    Frame damaged can mean the device does not respond, because i have some modbus meters that if i unplug the meter it comes back as frame damaged and there is no meter to respond, not just because the...
  5. Thread: Banned

    by hos
    Replies
    37
    Views
    3,282

    Hurry up and get Sysint back, he needs to answer...

    Hurry up and get Sysint back, he needs to answer my loytec post. LOL
  6. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    "You can check that box and then put in your...

    "You can check that box and then put in your multiplier and offset. No need to suffer. (screenshot)"

    Here's a good suggestion "What I find interesting is why the guy doesn't just email his config...
  7. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    Thanks Crab master for the assist in all this. ...

    Thanks Crab master for the assist in all this.

    If you see in the posts above the battery voltage say 538. The actual voltage on the read out display on the genset is reading 26.9 - 27V. The...
  8. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    How do you get the engine coolant being 40160? I...

    How do you get the engine coolant being 40160? I have put it in as decimal register 200. Is this wrong? I am using decimal in the loytec device.

    I am not sure if the system has a password set, i...
  9. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    I just upgraded the software to 4.2 and upgraded...

    I just upgraded the software to 4.2 and upgraded the firmware to V4.2.

    I have attached the config file. This is the best i've seen it so far, on first logging into the datapoints page all was...
  10. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    Polarity of modbus cable is correct, that was the...

    Polarity of modbus cable is correct, that was the first thing that was checked. All good.

    I had a tech come out from the generator company and he used moduscan to scan the device to see its...
  11. Thread: Loytec Modbus Help

    by hos
    Replies
    48
    Views
    3,480

    Loytec Modbus Help

    Hi All
    I hope you can help me with a problem i am having with a Loytec Linx200 Modbus-Bacnet converters.

    I am fairly new to modbus and don't know much about it as the controls we do are bacnet...
  12. Replies
    35
    Views
    4,419

    Thats some real nice work there. How long would...

    Thats some real nice work there. How long would it take you to make a picture like this one? I would think it would be around about 3-4hrs work, am i right?

    Very nice though. So you just import an...
  13. Replies
    9
    Views
    1,134

    Sent you the csv file Proto, i'm not sure that...

    Sent you the csv file Proto, i'm not sure that this can be changed. Maybe they have locked this feature so it can't be changed, which in my book is pretty useless as what happens when you have 2...
  14. Replies
    9
    Views
    1,134

    I have one of these meters that i'm testing, i...

    I have one of these meters that i'm testing, i can change the node ID but that does not in any way change the device instance. The device is bacnet IP only, it doesn't have MSTP.
  15. Replies
    9
    Views
    1,134

    Crompton Interga BACnet/IP meter

    Was wondering if anyone knows how to change the device instance on the Crompton Integra BACnet/IP meter. I have used ruinet to gain access to the csv file to make modifications. I have been able to...
  16. Replies
    38
    Views
    3,469

    Innotech are no longer a propreitry system they...

    Innotech are no longer a propreitry system they have now introduced BACnet into their hardware and their iComm server program. Not only are they open software(who give away their configeration...
  17. Replies
    35
    Views
    4,419

    We generally use autocad to pull the floor plans...

    We generally use autocad to pull the floor plans off, then make a jpg of them. Then we'll use photoshop to chage the colours etc
  18. Thread: Spyder Enhanced

    by hos
    Replies
    19
    Views
    1,391

    They have a good controller in their maxim111...

    They have a good controller in their maxim111 range with free software, what else do you want.
  19. Thread: People Counter

    by hos
    Replies
    1
    Views
    432

    People Counter

    Hey guys
    I have been asked to put 6 people counters on the doors of a shopping mall.
    What sort of information will they want to collect from these ie: total number of people and people per door.
    ...
  20. Replies
    0
    Views
    449

    LG Wiring Schematic

    Does anyone out there have a wiring diagram for a LG Ducted A/C
    Model LBF3660HL, its a 10.5KW reverse cycle unit.
    Im replacing the LG control with something better and need a wiring schematic.
  21. Replies
    0
    Views
    358

    LG Wiring Schematic

    Does anyone out there have a wiring diagram for a LG Ducted A/C
    Model LBF3660HL, its a 10.5KW reverse cycle unit.
    Im replacing the LG control with something better and need a wiring schematic.
    :)
  22. Replies
    32
    Views
    2,894

    As you have a load in the room even though it is...

    As you have a load in the room even though it is cold out side, install a hp control on the discharge pipe and set it up to a high setting like 2200kpa(r-22) and run a relay so that the condenser fan...
  23. Replies
    2
    Views
    515

    What happened to Turtle???????

    It's been a long time since i have seen a post from Turtle.
    Does anyone know whats happened to him?
    His posts were always go for a laugh!!
  24. Replies
    1
    Views
    1,661

    Sanyo Hermetic Compressor

    Hi all, just have a question on a Luke chiller(water cooled 2 comps) running on R-22 with liquid line solenoids each stage, the controls just got replaced with a ddc controller from original. The...
  25. Replies
    14
    Views
    1,509

    Is this a heat pump unit running under low...

    Is this a heat pump unit running under low ambient conditions?