08-12-2009, 02:09 PM
- Replies
- 3
- Views
- 300
Sounds like a load calculation needs to be done. ...
Sounds like a load calculation needs to be done. Seems like both are an overkill on the cooling side.
-
05-21-2008, 08:46 AM
- Replies
- 17
- Views
- 1,071
In both the heating and cooling mode a heat...
In both the heating and cooling mode a heat pump's amperage increases as the temperature increases. the amperage on the fan decreases as the filter or any air restriction increases.
-
05-21-2008, 08:39 AM
Thread: Interior Storm Windows
by travlinjohn- Replies
- 5
- Views
- 410
Interior storm windows will perform as well as...
Interior storm windows will perform as well as exterior storm windows (thermally) be careful to seal them well, as there is a chance if condensation forming between the wood window and the storm...
-
04-14-2008, 07:31 PM
Thread: Thoughts on Replacement Units
by travlinjohn- Replies
- 26
- Views
- 1,574
I agree with Redsheanazar
I agree with Redsheanazar
-
04-14-2008, 07:25 PM
Thread: How strong is the hvac industry?
by travlinjohn- Replies
- 13
- Views
- 991
Assuming you have the qualifications to be an...
Assuming you have the qualifications to be an HVAC contractor, the only way your new business will go is up. If you are starting out light, get a good service truck (not like what Fred Sanford would...
-
01-24-2007, 07:32 AM
Thread: contractor test in north carolina
by travlinjohn- Replies
- 14
- Views
- 934
NC exam
Steve,
My site, www.johnrwhite.net, has a practice HVAC exam for NC. It will give you an idea of what you're in for. Having read a number of posts about who's state has the toughest exam, this test... -
01-21-2007, 08:20 PM
Thread: Sanity Check?
by travlinjohn- Replies
- 15
- Views
- 837
sanity
It's your money. If you have the stuff just laying around I bet you,d get a better ROI putting it in an HVAC system. I do not believe you need a dual fuel system though.
-
01-21-2007, 02:20 PM
Thread: Sanity Check?
by travlinjohn- Replies
- 15
- Views
- 837
Your math is absolutely correct. Infact the...
Your math is absolutely correct. Infact the average COP would be a little higher than 3 with a 13 seer/ 8 hspf heat pump
-
01-21-2007, 02:08 PM
- Replies
- 7
- Views
- 490
Zoning and/or Heat Pump for Single Story Home in California?
According to you description of outdoor temperatures it sounds like you may not even need a furnace or auxillary heat with a heat pump. Find a contractor with enough intelligence to perform a load...
-
01-21-2007, 12:55 PM
- Replies
- 9
- Views
- 1,160
economic balance point
If you'll send me the local electric rates, gas rates with furnace AFUE, a copy of the load calculation and the name of the nearest large city I'll calculate the temperature setting for you. The...