  1. Replies
    4
    Views
    237

    my solution would involve a recovery machine and...

    my solution would involve a recovery machine and a scale as a starting point
  2. why not get the repair kit that trane offers for...

    why not get the repair kit that trane offers for it and repair it temporarily or just leave it until something else fails or until the new coil gets in. in the twenty five years I've been doing this...
  3. Replies
    26
    Views
    1,246

    if you haven't taken a superheat reading how do...

    if you haven't taken a superheat reading how do you know its flooding back? just because the suction line is frosting only means that it is below 32 degrees. example if I have 18 psi suction and a...
  4. I have seen it done on ice cream delivery trucks...

    I have seen it done on ice cream delivery trucks standard condensing unit under the side the only difference was they did not use an air over evaporator they had cold plates inside and static cooled...
  5. I'm thinking if you have a short run of duct to...

    I'm thinking if you have a short run of duct to the outside air that they are mist eliminators and should be washable in place, just a guess though.
  6. Replies
    2
    Views
    276

    the air handler is past its life expectancy, you...

    the air handler is past its life expectancy, you are close to the life expectancy of the condenser, as for as the heater goes if it is not rusted out and the electrical cape continue to use...
  7. plugged strainer also

    plugged strainer also
  8. Replies
    24
    Views
    932

    some places that you will be working may require...

    some places that you will be working may require you to wear gloves and/or suit to work in live control panels I have a suit and gloves I can put on if needed so that I do not have to wear the arc...
  9. if it is in the water circuit let it run out of...

    if it is in the water circuit let it run out of gas then the refrigerant circuit will fill with water rendering the unit useless and basically non repairable and then they would get off their butts...
  10. Thread: Tech.

    by chillerout1
    Replies
    9
    Views
    544

    did they show you how to do the scheduling in the...

    did they show you how to do the scheduling in the IVUE system? if they did just go into the schedule and set it like you want it. most of the time there is a class or training session built into the...
  11. Thread: Tech.

    by chillerout1
    Replies
    9
    Views
    544

    I'm not sure what you are asking for, are you...

    I'm not sure what you are asking for, are you wanting the inside temp to change at a gradual rate or the chilled water temp to change at a gradual rate because 72 degree chilled water isn't going to...
  12. are they split systems?

    are they split systems?
  13. I'm waiting on the pro press refrigeration...

    I'm waiting on the pro press refrigeration fittings to come out
  14. Replies
    7
    Views
    309

    do nothing and wait for compressor to blow. but I...

    do nothing and wait for compressor to blow. but I wouldn't worry too much about it based on conditions at the time the amps are within reason of operating specs
  15. Replies
    15
    Views
    530

    im puzzled why do you want a CO2 detector instead...

    im puzzled why do you want a CO2 detector instead of a CO detector? or why not both, co2 detectors in the rtus with economisers and powered exhaust and a CO detector tied to an exhaust fan and...
  16. most all WSHPs can be used for residential or...

    most all WSHPs can be used for residential or commercial as long as they are not three phase ,277v, or 480v
  17. what model number is it? and how are they...

    what model number is it? and how are they determining that it is a commercial unit?
  18. Replies
    28
    Views
    1,098

    im guessing your old unit is a lennox? and if...

    im guessing your old unit is a lennox? and if that's the case that is not a liquid line that is a cap tube( metering device). look and see if you have a txv on the system.
  19. Replies
    58
    Views
    1,975

    in our local it is up to the employer they can...

    in our local it is up to the employer they can bring you in as a journeyman or as an option you can take the journeyman (turnout ) test and possibly skip the apprenticeship
  20. Replies
    15
    Views
    717

    you are going to have to find a competent...

    you are going to have to find a competent professional in your area to check the system and determine your exact problem im leaning toward an eev or sensor problem with the beacon system they can...
  21. Replies
    15
    Views
    717

    sounds like you have an EEV problem not feeding...

    sounds like you have an EEV problem not feeding refrigerant properly
  22. Replies
    15
    Views
    717

    TEV or EEV? is the icing even or starting on one...

    TEV or EEV? is the icing even or starting on one side and working over until coil is iced but the beacon system should be determining defrost cycle unless you have it set for fixed defrost times ....
  23. Replies
    9
    Views
    253

    yes just gonna retro a carrier bracket into it

    yes just gonna retro a carrier bracket into it
  24. Replies
    9
    Views
    253

    air cooled chiller I believe it is from the...

    air cooled chiller I believe it is from the borg/warner era of York
  25. Replies
    9
    Views
    253

    looks similar but dimensions are different may...

    looks similar but dimensions are different may end up modifying one off of a carrier unit to fit