  1. a fan motor will only turn at it synchronous...

    a fan motor will only turn at it synchronous speed, minus slip, so it wont exceed it's rated load, would draw more if the pitch of the fan was too much and it was trying to move too much air
  2. Replies
    26
    Views
    1,937

    high resistance short, A short is a short, has to...

    high resistance short, A short is a short, has to be repaired
  3. Replies
    26
    Views
    1,937

    the difference is.....if you took the coil of...

    the difference is.....if you took the coil of wire out of the motor and streched it in a straight line drove a ground rod, connected it to 220 it would light up like a filiment in a bulb and burn up,...
  4. Replies
    26
    Views
    1,937

    one guy said the compressor coulod run forever...

    one guy said the compressor coulod run forever there is no gfci, another said the breaker was bad, I just saying if the compressor winding is shorted the breaker should trip nothing fancy, if it...
  5. Replies
    26
    Views
    1,937

    there is no ground, any breaker will trip if the...

    there is no ground, any breaker will trip if the winding is shorted to the compressor if the compressor is properly grounded. Has nothing to do with gfci, go figure, that's why the service ground is...
  6. Replies
    4
    Views
    524

    12 thhn good for 20 amps in my code book, the...

    12 thhn good for 20 amps in my code book, the only time it's good for more is to a motor
  7. Replies
    4
    Views
    524

    Not hvac but...

    hooking up a water heater, plainly stated on paperwork and unit must be no. 10 copper, open the heater and two no. 12's must be nice.
  8. Replies
    42
    Views
    2,943

    licensed plumber is right to add to a vent, a...

    licensed plumber is right to add to a vent, a vent doesent become a "wet vet just because you add a drip to it, go figure, any way a plumbing change might change the fixture load of the system....do...
  9. Replies
    42
    Views
    2,943

    if you run water to it it isn't a vent anymore,...

    if you run water to it it isn't a vent anymore, broke the code
  10. Replies
    42
    Views
    2,943

    it can go to the sewer, but it has to be a...

    it can go to the sewer, but it has to be a indirect connection
  11. Replies
    30
    Views
    1,746

    a 230 volt motor draws one half the amps same hp

    a 230 volt motor draws one half the amps same hp
  12. Replies
    30
    Views
    1,746

    no a 120 volt motor at reduced voltage draws less...

    no a 120 volt motor at reduced voltage draws less amps
  13. Replies
    30
    Views
    1,746

    NO, LESS voltage less amps

    NO, LESS voltage less amps
  14. Replies
    30
    Views
    1,746

    not so still single phase, just 240 volt if one...

    not so still single phase, just 240 volt if one phase goes out the voltage would only decrease
  15. Replies
    21
    Views
    1,445

    to change out a unit we are required to get a...

    to change out a unit we are required to get a permit, at least only one inspector come for the mech. and electrical
  16. Replies
    63
    Views
    3,438

    I carry my license with me and have a number for...

    I carry my license with me and have a number for my insurance
  17. Replies
    47
    Views
    4,599

    I guess the next time you get a headache you'll...

    I guess the next time you get a headache you'll be doing brain surgery, good luck, I hope you sleep well know a hack worked on your system, I do what I am trained to do nothing else.
  18. Replies
    47
    Views
    4,599

    yea they charge more for that but with the adding...

    yea they charge more for that but with the adding of tankless water heater might be more, out on a call now a diy homeowner, he replaced all the limit switches trying to repair his heat, now he's...
  19. Replies
    47
    Views
    4,599

    what does driving a train have to do with it?

    what does driving a train have to do with it?
  20. Replies
    15
    Views
    1,792

    that's one reason all the old mills had three...

    that's one reason all the old mills had three llights in the maintenance shop
  21. Replies
    47
    Views
    4,599

    yes after 30 years of electrical work

    yes after 30 years of electrical work
  22. Replies
    15
    Views
    1,792

    no, you never disconnect the neutral unless...

    no, you never disconnect the neutral unless gasoline is involved
  23. Replies
    47
    Views
    4,599

    call an electrican before you blow someone up

    call an electrican before you blow someone up
  24. Replies
    15
    Views
    1,792

    delta three phase is 120 degrees out of phase...

    delta three phase is 120 degrees out of phase with each other, with no neutral, the wye has a neutral, if it is three phase delta, not one of the conductors is grounded, you are going to hurt...
  25. Replies
    17
    Views
    1,805

    hope you're using the circuit breaker 3 amp they...

    hope you're using the circuit breaker 3 amp they sell it at the supply house wont burn out the transformer