  1. Replies
    213
    Views
    15,660

    I think the idea was that you could strap your...

    I think the idea was that you could strap your accessories to it with those slots.
  2. Replies
    78
    Views
    3,387

    I made several suggestions back when it was...

    I made several suggestions back when it was relatively new. He has really improved it over the last few years to the point that it's marketable IMO.
  3. Replies
    78
    Views
    3,387

    *

    *
  4. Replies
    78
    Views
    3,387

    9 or 10 seer CTD range is 15-25. Where did you...

    9 or 10 seer CTD range is 15-25. Where did you get this data?
  5. Replies
    30
    Views
    1,750

    Atmospheric pressure isn't the issue. The primary...

    Atmospheric pressure isn't the issue. The primary reason that charging in the rain can be problematic is that the condenser coil will likely be running wet, which will have a large effect on system...
  6. Replies
    186
    Views
    7,620

    There's little difference when TESP on high speed...

    There's little difference when TESP on high speed is over 1". At normal static pressures there's a significant difference in cfm between speeds.
  7. Replies
    27
    Views
    1,311

    And if it's a heat pump the only argument is...

    And if it's a heat pump the only argument is exposure to the elements. The entire condenser is out there though, sooo.... If I saw a lot of problems with driers installed outdoors I'd probably...
  8. Replies
    27
    Views
    1,311

    I've only ran across one rusted through drier in...

    I've only ran across one rusted through drier in the 30 years I've been doing this, and if I'm not mistaken that was only because it was completely buried in sand for 20 or 30 years and 10 feet from...
  9. http://hvac-talk.com/vbb/image.php?u=5587&dateline...

    http://hvac-talk.com/vbb/image.php?u=5587&dateline=1192655164&type=thumb
    Excuse me, did you say something?
  10. Replies
    186
    Views
    7,620

    So how many of you don't adjust blower speed...

    So how many of you don't adjust blower speed after major changes to the air circuit have been made? What happens to motor amps and static pressure when you increase the rpm to maintain the initial or...
  11. Replies
    30
    Views
    1,591

    If they're really bad I take them to the car wash.

    If they're really bad I take them to the car wash.
  12. Replies
    186
    Views
    7,620

    There are some energy costs. The blower requires...

    There are some energy costs. The blower requires more power to overcome the added air stream restriction. The lower coil temp also reduces the ac system efficiency.
  13. Replies
    14
    Views
    1,089

    It came with a calibration certificate from...

    It came with a calibration certificate from Transact. After reading the specifics of the calibration procedure I understood that it was calibrated correctly. The calibration sheet gives offsets which...
  14. Replies
    14
    Views
    1,089

    The dot matrix display is horrible. When the...

    The dot matrix display is horrible. When the value is changing you can't read the last digit or two or three. It also washes out at an angle. The meter itself was disappointing because the only time...
  15. Replies
    186
    Views
    7,620

    Worked it out on the chart. Yes, that works very...

    Worked it out on the chart. Yes, that works very well! Got it, thanks. I learned something new today.
  16. Replies
    186
    Views
    7,620

    It's about time! ;) I wouldn't have expected...

    It's about time! ;)

    I wouldn't have expected that much improvement by doing that. Very interesting.
  17. Replies
    186
    Views
    7,620

    Ok, I figured that in, and only got SHR of the...

    Ok, I figured that in, and only got SHR of the coil up to 0.39. Apparently we need another 5 or so of reheat (don't quote me on that number) from somewhere. Why don't you buy one of those...
  18. Replies
    186
    Views
    7,620

    That's worth nearly 1.5 of reheat at circa 400...

    That's worth nearly 1.5 of reheat at circa 400 SCFM. Given that the deltaT is only 10 that's actually quite significant.
  19. Replies
    186
    Views
    7,620

    The reason isn't difficult to discover. How many...

    The reason isn't difficult to discover. How many people keep their house at 80 and 60% RH? If the SST is running at close to or even below freezing under these conditions, what SST will it be...
  20. Replies
    186
    Views
    7,620

    Doesn't matter. At lower coil temps the SHR...

    Doesn't matter. At lower coil temps the SHR starts to go back up rather than down. The sensible capacity increases by a higher factor than the total capacity. The frost itself poses yet another...
  21. Replies
    186
    Views
    7,620

    When I plug the given data into my psychrometric...

    When I plug the given data into my psychrometric spreadsheet the unkown values magically appear, which is what it was designed to do. ;) Well there's a little more to it than that, I sometimes have...
  22. Replies
    186
    Views
    7,620

    How so? It's an invalid process. The process line...

    How so? It's an invalid process. The process line doesn't intersect the saturation curve. How did any condensation take place if none of the air dropped to its dewpoint? The leaving air condition...
  23. Replies
    186
    Views
    7,620

    There will be some small error due to the gasses...

    There will be some small error due to the gasses not being perfectly ideal, but nothing as great as what you've been led to believe. The thing about the process line being in reality a curve is...
  24. Replies
    186
    Views
    7,620

    That appears to be an invalid psychrometric...

    That appears to be an invalid psychrometric process.
  25. Replies
    26
    Views
    1,390

    Garden spider ...

    Garden spider
    ...
  26. Replies
    30
    Views
    1,591

    A dirty coil can cause this. The trap may also be...

    A dirty coil can cause this. The trap may also be inadequate.

    510391
  27. Replies
    41
    Views
    2,271

    Cleaning may cure it, but it could also be due to...

    Cleaning may cure it, but it could also be due to leaks in the coil. Oil from the system contaminates the fins and the water falls off. A quick scan with an electronic leak detector might save you...
  28. Replies
    17
    Views
    889

    The inrush current is reduced. Several...

    The inrush current is reduced. Several manufacturers make soft starters, and they're just speed controllers. They ramp up the motor.

    This article covers the technical aspects.
    ...
  29. Replies
    186
    Views
    7,620

    Theo, here's another way to say what I did above....

    Theo, here's another way to say what I did above. Suppose the system is initially dumping 1 gallon of water per cycle. It's running twice each hour, for 15 minutes each time. 50% load. The...
  30. Replies
    186
    Views
    7,620

    I don't believe that I insinuated anything, I...

    I don't believe that I insinuated anything, I stated outright that the starved coil, if bottom fed, will dehumidify better. :)

    Again, like PHM you're looking at size of the stream of water leaving...
  31. Replies
    32
    Views
    1,442

    Tightening up the house would certainly reduce...

    Tightening up the house would certainly reduce air conditioner power consumption, but this thing about start-up amps being a big expense is just ridiculous. Have you ever done the math?

    Suppose...
  32. Replies
    186
    Views
    7,620

    The behavior of the system as far as moisture...

    The behavior of the system as far as moisture removal and a low charge depends upon whether the coil is TXV or piston metered and upon how the evap coil circuit is configured. Be careful when...
  33. Replies
    186
    Views
    7,620

    The Sensible Heat Ratio is the sensible capacity...

    The Sensible Heat Ratio is the sensible capacity divided by the total capacity. At an SHR of 0.50 the sensible and latent capacities are equal. At higher SHRs the total capacity is mostly sensible,...
  34. Replies
    186
    Views
    7,620

    Latent capacity and SHR are different things. A...

    Latent capacity and SHR are different things. A low SHR is what you want for better dehumidification, the latent capacity is immaterial since the sensible capacity may be higher too. The shorter...
  35. Replies
    186
    Views
    7,620

    I was addressing this comment of yours in...

    I was addressing this comment of yours in particular. "...totally flooded evaps provide the highest latent removal ratio."

    What did you mean by that? I think we're on different pages. Maybe you...
  36. Replies
    186
    Views
    7,620

    Suppose return air dewpoint is 50. The coil is...

    Suppose return air dewpoint is 50. The coil is running with a SST of 50.5, so no condensation takes place. The charge is reduced until SST is 32. SH is high. Latent capacity is still zero? I'm...
  37. Replies
    213
    Views
    15,660

    It's always good to have a backup, that's one way...

    It's always good to have a backup, that's one way to look at it? Hmm...

    FWIW the wireless pressure transducers could easily be mounted to the manifold of your choice with the iConnect strapped to...
  38. Replies
    57
    Views
    2,968

    The more you add the less likely it'll freeze. If...

    The more you add the less likely it'll freeze. If you add enough refrigerant any drop in temp will actually diminish and can even disappear completely. That isn't common knowledge so I do my best to...
  39. Replies
    186
    Views
    7,620

    I need to clarify that the loss in capacity...

    I need to clarify that the loss in capacity mentioned above is only a loss compared to the TXV coil under the same conditions. Both systems will experience a gain in total capacity at lower ambients.
  40. Replies
    186
    Views
    7,620

    What's "correct" depends on how you define it....

    What's "correct" depends on how you define it. Fixed orifice systems provide superior part load dehumidification. The lower SST at lower ambients reduces the ADP, lowering the SHR. Part load...
  41. Replies
    213
    Views
    15,660

    Sounds great! I envision a suite of hvacr tools...

    Sounds great! I envision a suite of hvacr tools that would be selected from a drop-down menu in the iManifold app, enabled only for registered owners of either the iManifold or iConnect devices....
  42. Replies
    213
    Views
    15,660

    IIRC that's the very idea that led to the...

    IIRC that's the very idea that led to the iConnect.
  43. Replies
    16
    Views
    1,265

    Most likely a time delay module (anti-short-cycle...

    Most likely a time delay module (anti-short-cycle timer)
  44. Replies
    57
    Views
    2,968

    If you're going to service the equipment then you...

    If you're going to service the equipment then you need the proper tools on site. There's no point in speculating, not when you can measure.
  45. Replies
    60
    Views
    5,640

    Not quite the correct description but close...

    Not quite the correct description but close enough. The portion of air contacting the coil, if it's dropping moisture, must be below its own dewpoint and therefore at 100% RH. Assuming perfect...
  46. Replies
    4
    Views
    463

    I hope so, I've had mine in a lot of ducts.

    I hope so, I've had mine in a lot of ducts.
  47. Replies
    60
    Views
    5,640

    It might be easier to just remove BF from the...

    It might be easier to just remove BF from the output screen. What is your average tech going to do with it anyway?
  48. Replies
    60
    Views
    5,640

    Yep.

    Yep.
  49. Replies
    60
    Views
    5,640

    Yes and yes.

    Yes and yes.
  50. Replies
    60
    Views
    5,640

    On Brent's Trane belt driven unit I calculated an...

    On Brent's Trane belt driven unit I calculated an ADP of 46.7. His return air temp was 70-ish. SST was probably what? 40 tops? FWIW I had to use an ADP of 34 to get a BF of 0.56 out of his air...