04-14-2011, 05:40 PM
Thread: slow script
by mknox- Replies
- 3
- Views
- 1,868
slow script
every time i try to surf around this site i get a "slow script" message. any time i click on anything at all, i get the same. anybody have any help? i an using a mac with safari fyi. thanks
-
uv lights
whats the deal with 24v uv lights? how do they compare withe 120v ones?
-
07-31-2008, 12:47 AM
Thread: Heat Pump Questions
by mknox- Replies
- 11
- Views
- 659
york champion hps use a pressure switch to...
york champion hps use a pressure switch to initiate defrost.spiders are the biggest pain in the ass with the ps tubing in an odu. actually these champion units really live up to their name. ive...
-
07-30-2008, 12:58 AM
- Replies
- 25
- Views
- 1,555
um..are you sure? i always found that a larger...
um..are you sure? i always found that a larger coil surface equals more moisture removal. of course it needs to be set up correctly.
-
07-30-2008, 12:51 AM
Thread: CFM questions...
by mknox- Replies
- 5
- Views
- 708
cfms
your contractor should be able to tell the cfms for each and every branch run of your ducting before they begin the install. a proper duct layout is based partially on the amount of cfms needed to...
-
07-30-2008, 12:33 AM
Thread: Have you heard of this?
by mknox- Replies
- 26
- Views
- 2,188
speaking of the IAQ
speaking of the IAQ, just installed my first one the other week and found it pretty slick. just wondering if anybody has a link to any helpful info about setting these things up and/or wiring them....
-
07-27-2008, 03:25 AM
Thread: Is water flowing?
by mknox- Replies
- 4
- Views
- 461
as far as my experience goes, most of the newer...
as far as my experience goes, most of the newer geothermal hps that ive installed/serviced have a dedicated dhw mode. actually on hydroheat and waterfurnaces it runs before 1st stge heating and...
-
07-26-2008, 03:09 AM
- Replies
- 16
- Views
- 799
increased pain in the ass! really i think that...
increased pain in the ass! really i think that modulating furnaces may catch on, but they like every modern geothermal hp i see, are extremely over engineered!!! seriously 300-600$ control...
-
07-20-2008, 03:36 AM
Thread: target superheat
by mknox- Replies
- 33
- Views
- 5,573
sorry about that...
sorry about that...
-
07-20-2008, 03:29 AM
Thread: 20 degrees?
by mknox- Replies
- 7
- Views
- 658
i thought that most heat loads are figured with...
i thought that most heat loads are figured with an odt of no more than 95. i live in pa so i guess this would vary from region to reigon,
-
07-19-2008, 03:29 AM
Thread: target superheat
by mknox- Replies
- 33
- Views
- 5,573
target superheat
i realize that if there is a chart in/on the odu its best to use it; but i see alot of units with only subcooling charts on them. if its got a txv, no good. our company will work on anything so i...
-
07-18-2008, 12:45 AM
Thread: target superheat
by mknox- Replies
- 33
- Views
- 5,573
target superheat
so ive seen a number of target superheat charts around but am wondering a calculation ive recently stumbled upon. wet bulb times 3,minus 80, minus outdoor ambient temp.. just wondering if most use a...
-
07-13-2008, 03:57 AM
Thread: Walk in Freezer questions
by mknox- Replies
- 27
- Views
- 3,336
so go ahead and explain subcooling the same way...
so go ahead and explain subcooling the same way...