Search:

Type: Posts; User: Cable Tech

Search: Search took 0.00 seconds.

  1. Replies
    5
    Views
    1,413

    Thanks, Enjoy you site. One well in Castle Hayne...

    Thanks, Enjoy you site. One well in Castle Hayne aquifer. 105 ft deep drawing from 36 feet. Water is at 8 ft. We dump back into Pamlico River which is 150 ft. from front door. Pump does 25 gal./min....
  2. Replies
    5
    Views
    1,413

    Yes

    Yes
  3. Replies
    5
    Views
    1,413

    SkyHeating or anyone who may know

    SkyHeating has a web sight with a live closed loop system shown. The difference between the EWT and the LWT is on average 3.5 degrees cooler. Is this a benchmark average or just average for this...
  4. One well which can do easy 25 gpm. Trick is to...

    One well which can do easy 25 gpm. Trick is to bal. for operation of both units at one time. Each unit is easy, both together a little more challenging. Do I set both to each up at high gpm by them...
  5. Have 2 Bocsh split systems, new build. a TA 035...

    Have 2 Bocsh split systems, new build. a TA 035 and a TA 049. Both on open loop with discharge into river. What to balance each with manual Nexus valves. Water 62 degrees now. Only tables Bocsh show...
  6. Tables or charts on temp. drop and pressure drop in cond. heat transfer coil

    Where do you find the charts on temperature drop and pressure drop? Is there a chart for each manufacturer or is there a generic chart which covers all units?
  7. Replies
    3
    Views
    1,472

    Missed the graph. Neet. System I'm putting in is...

    Missed the graph. Neet. System I'm putting in is Bosch TA 049 and TA 035 for upstairs. Both open loop with discharge into Pamlico River. Well 150 ft. pump at 30 ft. proofed to 60 gpm need 20 gpm if...
  8. Replies
    3
    Views
    1,472

    Talking to a Bosch engineer and he said I could...

    Talking to a Bosch engineer and he said I could expect durring the summer 130 degree water from loop on desuperheater and thermostat on loop was set to 130 degrees. Should I expect a much lower loop...
  9. Replies
    3
    Views
    1,472

    Desuperheater information

    Installing a Bosch TA 049 split system. Heater tank is 60 gal. 2 feet from condenser so pipes will be short. I intend to use the 60 gal. tank as a holding tank which will be in series with a EZ on...
  10. Replies
    2
    Views
    809

    thanks, plumbing today

    Plumbing today. Got a good 2" strainer ready almost to fire up!
  11. Replies
    2
    Views
    809

    Hello from Washington NC

    Weathered storm here fine. Live on Pamlico River. Water came up about 3 ft. on storm approach and went down 4 ft on storm departure. Winds 30 to 40 knots. Still cloudy here this am but a lot cooler....