  1. Here is a chart which shows Fujitsu allowable...

    Here is a chart which shows Fujitsu allowable matches


    http://catalogs.johnstonesupply.com/4299_john_206/full.asp?page=643#catalog
  2. Thread: YMGI

    by BURL-REF
    Replies
    2
    Views
    298

    I got a ad slicker with prices for their...

    I got a ad slicker with prices for their equipment, not impressed
  3. Set the remote on "DRY " mode and turn your temp...

    Set the remote on "DRY " mode and turn your temp down to 64. Check humidity level after a day or so
  4. Replies
    7
    Views
    365

    that system wont work with those evaps, its too...

    that system wont work with those evaps, its too many btu's. It's maxed out with 2-12,000

    you'll need a 36,000 condenser. Pony up more money
    ...
  5. Replies
    13
    Views
    687

    That type line set I've seen before. I replaced...

    That type line set I've seen before. I replaced with a copper line set. The line set looked like that one in the pic, but the inner liner was some type of plastic, that's why it was bound with the...
  6. I would return it.

    I would return it.
  7. when you do "test" on these, you need to do one...

    when you do "test" on these, you need to do one at a time. Sounds like the installer needs to come back. Is this a brand new install ?
  8. were at 4% leakage on new systems.

    were at 4% leakage on new systems.
  9. Replies
    13
    Views
    726

    If the fan coil was heated by a water heater,...

    If the fan coil was heated by a water heater, said relay is code. It keeps the water in the coil refreshed as to not build up bacteria. If your using a boiler, you probably don't need the pump...
  10. Replies
    32
    Views
    1,674

    I had a trane 2 ton system which would trip now...

    I had a trane 2 ton system which would trip now and then. Turned out that baby mice found their way down the feed from the disconnect to the compressor, and chewed the wires. Replace the wiring and...
  11. Trane makes a slide in hot water coil for that...

    Trane makes a slide in hot water coil for that air handler, the installers should have used that.
  12. Replies
    11
    Views
    794

    If this is a brand new system, you need to get...

    If this is a brand new system, you need to get them back to install this correctly. Its not even close to factory piping.
    You should have the 135 page install book .
  13. Replies
    19
    Views
    1,650

    get a new company. On & off every 5 minutes, WOW,...

    get a new company. On & off every 5 minutes, WOW, I sure don't want that electric bill
  14. Did the installers seal all the line set...

    Did the installers seal all the line set penetrations to the outside ?
  15. Vintage Air ran a Studebaker at 200 mph with air...

    Vintage Air ran a Studebaker at 200 mph with air on, at the Salt Flats as a test and had no issues

    http://www.vintageair.com/video_choices.htm
  16. Thread: Chimney Liner

    by BURL-REF
    Replies
    23
    Views
    2,123

    never seen a power vented water heater enter...

    never seen a power vented water heater enter chimney.
  17. Replies
    14
    Views
    1,140

    Sounds like you share a common wall. If so, try...

    Sounds like you share a common wall. If so, try this for a day or 2.
    Get some painters tape and cover up all electrical outlets / openings on that wall.

    Next, if you have an attic space,...
  18. Replies
    14
    Views
    1,140

    I just read this article. Maybe it applies to...

    I just read this article. Maybe it applies to you.

    " A California city has imposed a ban on smoking in residential homes.



    The city council in San Rafael, Calif., passed Assembly Bill...
  19. Replies
    15
    Views
    1,999

    Have a look at this video by Ultra Fin. You may...

    Have a look at this video by Ultra Fin. You may find there are not enough fin sections in your install. You need to get this straightened out quick and get that outdoor sensor working. Ask the...
  20. Replies
    1
    Views
    411

    I installed a 155 model, it has the primary loop...

    I installed a 155 model, it has the primary loop installed with the option to not use it via shut off valve.

    the 70 and 110 do not have this feature
  21. you should be checking them filters every 3 to 4...

    you should be checking them filters every 3 to 4 weeks. It only takes a few minutes
  22. Your chimney is now to big for just a water...

    Your chimney is now to big for just a water heater. Once you removed the furnace, in most states its required to line the chimney with a properly sized liner, whether its an interior or exterior...
  23. Replies
    3
    Views
    883

    board one Links to direct purchase sites aren't...

    board one
    Links to direct purchase sites aren't permitted here.
  24. Replies
    4
    Views
    978

    Best to get more estimates. Don't think you'll...

    Best to get more estimates. Don't think you'll even get 14 out of them air handlers,, especially with a piston. First Co has no ratings on their site. Trane and American Standard have an air handler...
  25. Replies
    10
    Views
    1,089

    I will do that in the future, thanks

    I will do that in the future, thanks
  26. Replies
    10
    Views
    1,089

    Thank you Bob , and rundawg for your input....

    Thank you Bob , and rundawg for your input. Rundawg, thanks for the email with the part numbers, your a great asset to the forum having all this info for the asking.

    I searched my 4 suppy houses...
  27. Replies
    10
    Views
    1,089

    It is an OE motor

    It is an OE motor
  28. Replies
    10
    Views
    1,089

    Arco Aire AG036GB2 s# L982353770

    I'm looking for the specs on the dual capacitor for this unit. I changed the condenser motor on Saturday and found the dual cap was 45/5 @ 370v.
    Problem is the old fan and new fan state 3 mfd @...
  29. Have your tech use his scale for weighing in the...

    Have your tech use his scale for weighing in the r-22
  30. Replies
    12
    Views
    1,049

    I would pull the remaining Freon and start over....

    I would pull the remaining Freon and start over. Pressure test the complete system with nitro, and vac / recharge
  31. Replies
    11
    Views
    1,050

    I think he want s utilize the downflow and add...

    I think he want s utilize the downflow and add more duct to the side outlet.
  32. Replies
    6
    Views
    966

    http://www.pexsupply.com/Bell-Gossett-Hydronic-BPX...

    http://www.pexsupply.com/Bell-Gossett-Hydronic-BPX-Brazed-Plate-Heat-Exchanger-With-Mounting-Tabs-1694000
  33. Replies
    17
    Views
    3,209

    How about insulating that steam pipe

    How about insulating that steam pipe
  34. Replies
    9
    Views
    3,385

    Your lines in the wall would enter from the left...

    Your lines in the wall would enter from the left side and you can get at the connections by holding the bottom out off the wall. The back plate shows where to enter and has marks to determine the...
  35. Replies
    7
    Views
    1,739

    Under the house ?

    Under the house ?
  36. Replies
    7
    Views
    1,393

    I buy at about 20% less than acwholesales offer.

    I buy at about 20% less than acwholesales offer.
  37. Mark. these thermostats are called type 2, there...

    Mark. these thermostats are called type 2, there is no deadband on them, they either make r&w or r&y. There is no in between.
  38. Just so you dont waste time searching the web for...

    Just so you dont waste time searching the web for a new one, they mandated all mercury stats taken off the shelves , and not to be sold. Some company picks them up as they are hazardous waste.
  39. I just went through this with my customer. Oil...

    I just went through this with my customer. Oil burner tech offered 3 new t87 stats with new oil furnace. What a mess he had. Those stats are not available anywhere I looked. They are not your...
  40. One supply and 2 returns. Each return would need...

    One supply and 2 returns. Each return would need a purge / balance valve if any balancing needed to be done.
  41. Replies
    11
    Views
    1,637

    Thanks I will call around and find a contractor...

    Thanks I will call around and find a contractor who is willing to do those checks tomorrow as there are no residental contractors listed in Utah on the locator map. All the installer companys has...
  42. Fujitsu requires 9 feet for cooling units and 16...

    Fujitsu requires 9 feet for cooling units and 16 feet for heat pumps
  43. Why cant to have a chimney company install a...

    Why cant to have a chimney company install a liner in the existing chimney ? Is looks like your chimney is outside the home ? A liner would sure help with the draft, and eliminate all mechanical...
  44. Replies
    28
    Views
    4,498

    I agree with a liquid line solenoid. Not pumping...

    I agree with a liquid line solenoid. Not pumping the unit down, just closing when the call is satisfied. Install it in the liquid line close to the evaporator. That will keep liquid from migrating on...
  45. Replies
    27
    Views
    3,781

    2 ton system

    2 ton system
  46. Replies
    8
    Views
    3,151

    Easiest way to check is: Power up outdoor...

    Easiest way to check is:

    Power up outdoor system
    Both remote units off
    Power up only one remote unit
    If that indoor unit starts, it wired and piped right.
    If it doesnt start, go check...
  47. Replies
    7
    Views
    2,124

    Trane and American Std are the same company. EX:...

    Trane and American Std are the same company. EX: TUD2Bo60 for trane, AUD2B060 for American std. Not sure but I think the coils and comp units carry the same model numbers. 4* means refrigerant 410A....
  48. Replies
    8
    Views
    3,151

    So Daikens dont come with any charge in them ?

    So Daikens dont come with any charge in them ?
  49. Replies
    18
    Views
    9,383

    Most if not all mini's can be roughed in , from...

    Most if not all mini's can be roughed in , from the left side before sheet rock. And if you need to remove the evap unit , it is easier to remove. Unlike when you have them on the right end and going...
  50. Replies
    3
    Views
    762

    Why not get the matching coil for that furnace ?...

    Why not get the matching coil for that furnace ? Other wise you need to transition between the furnace & coil then up to the main.