Search:

Type: Posts; User: jim bergmann

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    1,178
    Views
    131,616

    The iManifold does not calculate target superheat...

    The iManifold does not calculate target superheat for a TXV system. If I had to guess, you were in a profile, and benchmark a system and it stored those superheat and subcooling targets as the...
  2. Replies
    1,178
    Views
    131,616

    We are working on both current and voltage....

    We are working on both current and voltage. Kicked the cat out of the bag awhile ago. That is a neat product. Not sure that I would trust it on 600 volts looking at the housing, but I really like the...
  3. Replies
    687
    Views
    53,390

    Yes, it is always being updated. We are on...

    Yes, it is always being updated. We are on version 33. It is in Beta testing now. Should go into general release this week.
  4. Replies
    1,178
    Views
    131,616

    Thanks for the feedback. It is a labor of love or...

    Thanks for the feedback. It is a labor of love or I would not do it. There are a ton of new features coming over the next few weeks. The programming team has been busy.
  5. Replies
    1,178
    Views
    131,616

    It will be different for sure, i would recommend...

    It will be different for sure, i would recommend that you set it up the the manufacturer specifications and then use the benchmarking feature to calculate and record the design temperature...
  6. Replies
    1,178
    Views
    131,616

    Great question, yes there is, just like there is...

    Great question, yes there is, just like there is an optimal place to measure temperature split, temperature rise or superheat. If it is not in a good location you will not get optimal results. 6-10...
  7. Replies
    1,178
    Views
    131,616

    What you are seeing is the network trying to...

    What you are seeing is the network trying to repair itself. It will do that when it is looking for alternate paths do to low signal strength. Most customers do not require repeaters, but every so...
  8. Replies
    1,178
    Views
    131,616

    It is on the drawing board, but not real soon. If...

    It is on the drawing board, but not real soon. If I had to guess, I would say 4-6 months out. We just started really looking at it and working on a requirements document.
  9. Replies
    1,178
    Views
    131,616

    The GPS is now optional, it will be updated in...

    The GPS is now optional, it will be updated in the next app release. Hopefully we will have it out of beta testing by the end of next week. That should allow you to do the download and use it without...
  10. Replies
    687
    Views
    53,390

    The iConnect should stay with you. Not sure how...

    The iConnect should stay with you. Not sure how long you waited, but as you move around the iConnect has to reconfigure its path. When you say lost connection, I am assuming that you mean you lost...
  11. Replies
    12
    Views
    473

    Absolutely. Works with cell phones too. The...

    Absolutely. Works with cell phones too. The stuff will last in the tub for several months if not a year or better if it is sealed tight. So it is very handy to have around With sensitive...
  12. Replies
    12
    Views
    473

    Most instruments are water resistant not water...

    Most instruments are water resistant not water proof. The easiest thing to do is to go to Walmart and buy a tub of damp rid. It is about $6.00. Pour about 1/3 of the tub into a zip lock bag or a...
  13. Replies
    687
    Views
    53,390

    Not at the moment. There are some other...

    Not at the moment. There are some other development areas ahead of that.
  14. Replies
    687
    Views
    53,390

    That is in the plan. The IManifold would simply...

    That is in the plan. The IManifold would simply act as another wireless probe. Not much demand for that yet as the wireless probes are filling that roll, but we agree.
  15. Replies
    687
    Views
    53,390

    Put the tee between the probe in the hose instead...

    Put the tee between the probe in the hose instead of at the hose end.
  16. Replies
    687
    Views
    53,390

    Marc, At this time no, but it is in the...

    Marc,
    At this time no, but it is in the planning. That is my background also. It is a few months worth of work. Currently, the iConnect could be used for everything except calculating the BTUH and...
  17. Replies
    1,178
    Views
    131,616

    For the application to calculate performance it...

    For the application to calculate performance it has to have an airflow input or be in the range where it can accurately calculate airflow. This means the RAWB needs to be above 50 degrees F and the...
  18. Replies
    687
    Views
    53,390

    The first time I saw the strap probes I thought...

    The first time I saw the strap probes I thought it was a stupid idea myself. I did not like them in concept. I used them for a few days and liked them much better then the clamps that I had been...
  19. Just standard high quality vacuum pump oil will...

    Just standard high quality vacuum pump oil will work for short term use,, but there are higher end oils for continuous use. We sell one for that pump, Airserco part # 20001160. You can order it...
  20. It is just a high end vacuum pump for scientific...

    It is just a high end vacuum pump for scientific work. See below. Leybold is a brand that Stride Tool services through a sister company Airserco

    http://airserco.com/products/vacuum-pumps
    ...
  21. Replies
    687
    Views
    53,390

    What you run the app on makes a huge difference,...

    What you run the app on makes a huge difference, some of the older android devices just do not perform well. It is just a function of their processing power. We have found that Apple devices run the...
  22. Replies
    687
    Views
    53,390

    Great, glad you are set.

    Great, glad you are set.
  23. Replies
    687
    Views
    53,390

    It should work if you have android 4.2 or newer...

    It should work if you have android 4.2 or newer on that. Have you paired it? Android requires pairing.
  24. Replies
    687
    Views
    53,390

    Also make sure your app is up to date.

    Also make sure your app is up to date.
  25. Replies
    687
    Views
    53,390

    LP, HP, SLT, LLT, ODA, Radb, Rawb, Sadb, Sawb,...

    LP, HP, SLT, LLT, ODA, Radb, Rawb, Sadb, Sawb, tonnage if using auto airflow calc, or airflow. That should do it.
  26. Replies
    687
    Views
    53,390

    Rick, Some terms, A profile is a set of...

    Rick,

    Some terms,

    A profile is a set of variables that determine how an A/C unit should work.

    A project has a profile associated with it and is what is used to generate a report

    Some...
  27. Replies
    687
    Views
    53,390

    Auto saved

    Auto saved
  28. Replies
    687
    Views
    53,390

    Yes, go into reporting and projects. Once inside...

    Yes, go into reporting and projects. Once inside the projects the profiling is there. It will disappear from the left-hand menu while you were in a project and will not reappear until you exit...
  29. Replies
    687
    Views
    53,390

    Rick, Yes it has everything to do with...

    Rick,

    Yes it has everything to do with accuracy. You do not want a higher range then you need for the application. The sensors are rated at a percentage of full scale. So the larger the scale, the...
  30. Replies
    687
    Views
    53,390

    I would use outdoor air for sure. The one in you...

    I would use outdoor air for sure. The one in you cooper kit will work. Use in the t2 of the Suction probe and map it to ODA. It could also go in the iConnect, but typically you carry it with you.
  31. Replies
    687
    Views
    53,390

    The total load (return air heat, humidity, and...

    The total load (return air heat, humidity, and the volume) also drives the head pressure, so low airflow which affects many systems (studies show as high as 70%) will keep the head pressure below...
  32. Replies
    18
    Views
    1,375

    The ones you want have a green tint, and they do...

    The ones you want have a green tint, and they do work. They take a load off your eyes. But warning. Do not ware them as sunglasses when driving. You cannot see break lights at all with them on. Reds...
  33. Replies
    687
    Views
    53,390

    Could have been either, but probe placement is...

    Could have been either, but probe placement is very important. Make sure you are in the condenser air stream, not just hanging in the ambient air.
  34. Replies
    687
    Views
    53,390

    Glenn, The free report will be a lot different...

    Glenn,

    The free report will be a lot different then the free one. Let alone easier to generate, we are including a geo tag map, pulling in weather data, including a place for any photo you would...
  35. Replies
    687
    Views
    53,390

    Glenn, The high side target is driven by the...

    Glenn,

    The high side target is driven by the outdoor air temperature. Typically the high side saturation temperature should not be any higher then 30 degrees hotter then the outdoor air...
  36. Replies
    1,178
    Views
    131,616

    Tap on the blue box to the right of the project...

    Tap on the blue box to the right of the project name under reporting and tap delete when the prompt comes up.
  37. Replies
    5
    Views
    907

    Looks cool, nice job!

    Looks cool, nice job!
  38. Replies
    5
    Views
    907

    Looks great, I would like to see it all together.

    Looks great, I would like to see it all together.
  39. Replies
    687
    Views
    53,390

    Jared, You meet me then because I am the son....

    Jared,

    You meet me then because I am the son. I live in Akron, so not far from you. If you want to meet me at my place or you want to meet somewhere else I am game. Imperial is in Solon, so about...
  40. Replies
    24
    Views
    1,550

    The gauge is displayed on your smart device, if...

    The gauge is displayed on your smart device, if you meant the manifold, you can easily do it with an inline finger tight tee.
  41. Replies
    687
    Views
    53,390

    It was a good start of the additional information...

    It was a good start of the additional information you can get. I see you are in Ohio, how far are you from Cleveland? If you would like to stop by Imperial, I would be glad to give you a hands on...
  42. Replies
    687
    Views
    53,390

    No, but I can put it on the list.

    No, but I can put it on the list.
  43. Replies
    24
    Views
    1,550

    This is the kit that I would look at. It is...

    This is the kit that I would look at. It is everything that you need in one package. Use the hvac-talk discount code.

    http://www.trutechtools.com/Imperial917C

    Jim
  44. Replies
    687
    Views
    53,390

    Thanks for the very positive feedback Tommy, you...

    Thanks for the very positive feedback Tommy, you are welcome! Thanks for your business!

    Jim Bergmann
  45. Replies
    24
    Views
    1,550

    There are only a few ways to achieve a higher...

    There are only a few ways to achieve a higher SEER rating. In order to do it the compressor has to not work as hard. They need to lower the compression ratio.

    What is done typically is increase...
  46. Replies
    24
    Views
    1,550

    Set up the equipment to the manufacturers...

    Set up the equipment to the manufacturers specification. Make sure everytthing is perfect, clean coils, blower, filters etc. Follow their instructions exactly in the commissioning process.

    Go to...
  47. Replies
    24
    Views
    1,550

    How do you want it rated? EER, COP, it is all The...

    How do you want it rated? EER, COP, it is all The same equipment, we just have to figure out how to convert it to the energy efficiency ratings you want to see. SEER x .8 is approximately the EER.
  48. Replies
    24
    Views
    1,550

    Thanks for the feedback, we are here all the time...

    Thanks for the feedback, we are here all the time and keep an ear to the ground.
  49. Replies
    24
    Views
    1,550

    DTD is Design temperature difference. It goes...

    DTD is Design temperature difference. It goes back to engineering design. It means how much colder is the evaporator then the medium being cooled and how much hotter is the condenser then the outdoor...
  50. Replies
    24
    Views
    1,550

    Both of them are large customers of Imperial, so...

    Both of them are large customers of Imperial, so if you have not seen one, its only because they are not stocking them at the branch at the moment. They likely have them in their central distribution.