  1. Replies
    16
    Views
    410

    wow , you might need a liquid line solenoid to...

    wow , you might need a liquid line solenoid to shut off when contactor shuts off ??

    I think id crank the liquid valve off real quick after shut down , then crank her up for a couple seconds to see...
  2. Replies
    9
    Views
    282

    I once shoved pipe insulation under the plastic...

    I once shoved pipe insulation under the plastic drain pan to raise it , so the water slopes more towards the drain hole and cant really build up water near the fan box
  3. SH sounds fine , but thats after you added 1...

    SH sounds fine , but thats after you added 1 pound .... hmm

    Might be over charged now due to that screen clogged ?

    You need to get that screen out no matter how , cut it out , pull it out ,...
  4. Replies
    6
    Views
    234

    Gummed up Txv ? or Leak someplace ?

    410 unit split 3Ton , year n half old, customer changes filters often, called me last night and said coil is a block of ice,so before I travel an hour out to the county to them, how can I tell the...
  5. A12-701 , weave 2 feet thru coil , set on 5 , go...

    A12-701 , weave 2 feet thru coil , set on 5 , go home
  6. Replies
    6
    Views
    188

    You think I can use it in USA being 50 hz ?

    You think I can use it in USA being 50 hz ?
  7. Replies
    6
    Views
    188

    I never thought it would work .... until .... i...

    I never thought it would work .... until .... i saw a compressor in my shed listed both Hz on it

    and that particular one is a CR18KQ-PFV-980WB From a walk-in cooler
  8. Replies
    6
    Views
    188

    50 HZ compressor

    Got 3 at auction , didnt see the 50 HZ until i went to install it :det:

    I've seen other compressors list both voltages 60 HZ 208 - 230 v .... and 50 HZ 200 v

    But this just has 50 HZ 220 - 240...
  9. Replies
    8
    Views
    267

    Ive seen some guys swear by the 1560 and was...

    Ive seen some guys swear by the 1560 and was curious why they prefer those
  10. Replies
    8
    Views
    267

    A12-700 vs A12-1560

    What would make you choose one or the other .....

    1560 Cold "off" is 19 and ON 38

    700 Cold "off " 11.5 and ON 37

    at their lowest setting

    Both "Normal " off 24
  11. Replies
    12
    Views
    300

    pressures and temps sound fine to me maybe HP...

    pressures and temps sound fine to me

    maybe HP Sensor bad .... i see many bad on package units , largely Tranes , and when i block condenser to test sensors they work fine , but soon as i leave...
  12. Replies
    87
    Views
    2,373

    I know , I have a few Food Trucks too , and...

    I know , I have a few Food Trucks too , and wonder how in the hell they survive in that heat ....but they do

    I read somewhere R22 and Mineral will produce acid when ran hot too long , which will...
  13. Replies
    18
    Views
    791

    I've done this on cheap ass customers. You...

    I've done this on cheap ass customers.

    You can drive a Torx bit in there with hammer possibly on yer next one ....
  14. Thread: Stumped

    by Snapperhead
    Replies
    22
    Views
    1,036

    only couple things I can think of that make...

    only couple things I can think of that make suction high , Txv wide open , or RV leaking , outside air entering return ( you might need to pull tin box off to check if flex came off )
  15. Replies
    87
    Views
    2,373

    Sounds like one i did. Mine started off with...

    Sounds like one i did. Mine started off with burnout , change compressor , blow both coils out , replace cap tube , acid away , new stat , lasted one week before going into vacuum. Replaced cap again...
  16. Replies
    5
    Views
    265

    I know right ..... I had to look twice and even...

    I know right ..... I had to look twice and even thrice , yea buddy its a 2.3 w

    .15 amp

    Cw 1300
  17. Replies
    5
    Views
    265

    Yea i figured sh would be higher but dunno how...

    Yea i figured sh would be higher but dunno how much, or if it cares. I threw fan on..... waiting for stat to satisfy now
  18. Replies
    5
    Views
    265

    true undercounter cooler

    evaporator motor is a 2.3 w, 1300 rpm, 120 volt, nobody carries that,can I use a 4 Wat, 1500 rpm
  19. Replies
    14
    Views
    891

    Musta been a donut shop next block over

    Musta been a donut shop next block over
  20. Replies
    14
    Views
    891

    Last week we were working NEAR the P r o j e c t...

    Last week we were working NEAR the P r o j e c t s at this little restaurant , and in the back alley we were running the line-set for a mini -split , and as you know most are wayyy too long , so we...
  21. Down there is one compressor for AC , a second...

    Down there is one compressor for AC , a second one is located on left side
  22. Front And on the other side of that coil is...

    Front

    And on the other side of that coil is the outdoors

    Fan blows hot air outside , and ofcourse when the cover is on , it sucks fresh outside air in thru coil
  23. That gadget is leaking This is looking into...

    That gadget is leaking

    This is looking into the left side panel

    Fan is turning , thats why fan looks weird .....
  24. Here she is That tiny return grille is for...

    Here she is

    That tiny return grille is for that room , the plenum goes into ceiling for rest of store , and under that Grille / hood is Evap
  25. Last night had the wife sit in the truck , she...

    Last night had the wife sit in the truck , she had her Smith sitting in her lap. I always pack mine when "downtown"

    I have a handful of Indians who own a bunch of Gas stations and Subways and...
  26. I can upload pics later .... Went there and...

    I can upload pics later ....

    Went there and removed panels , its got 1 compressor for cooler located in the middle of tin box , and cond coil and fan share that space , then on bottom of box are...
  27. Replies
    2
    Views
    261

    Bridged it up , and it fired up like magic ........

    Bridged it up , and it fired up like magic ..... thanks
  28. Refrigeration / Air Conditioner system , WTH

    Just got back from a Gas Station who has a Frozen over 6 fan evap in the beer cooler

    Im like, no problem just shut off compressor until the morning.

    They show me to the back room where this...
  29. Replies
    7
    Views
    335

    Yea those 700 ones are good for 38 box , but like...

    Yea those 700 ones are good for 38 box , but like you mentioned, its a pain when its humid. Cut out is 11 degrees if they crank her all the way down to # 7 on knob , and thats just begging for ice up
  30. Replies
    2
    Views
    261

    Bench Testing Hoshi Water Pump

    AP-TA4 , PA 0613 motors , same same

    I have one that had a broken impeller and would like to order the 40 dollar impeller kit for it , but after getting impeller off and plugging the black...
  31. Replies
    7
    Views
    335

    I use 700 on beer coolers , 701 is a little nicer...

    I use 700 on beer coolers , 701 is a little nicer to the lettuce
  32. Replies
    7
    Views
    335

    A12-701 vs Low press sensor

    On reach ins , which works best ?
  33. Replies
    4
    Views
    278

    No loop , goes direct to condenser

    No loop , goes direct to condenser
  34. Replies
    4
    Views
    278

    turbo air leaking

    Stand up single door cooler , stainless , i assume its likely in evap ? Anybody know the track record of these? It was 94 and humid in the shed they keep it in , so i gassed up and left for now....
  35. If charging on a 90 degree day , you clear sight...

    If charging on a 90 degree day , you clear sight glass when its down to temp , then add more refrigerant for "winter time" and there is a formula to calc that amount.

    If you dont know that...
  36. The King valves come closed off , even on...

    The King valves come closed off , even on receiver , did you open all valves ?
  37. Replies
    19
    Views
    1,013

    Sprayer , or hair dryer I dunno why , but a...

    Sprayer , or hair dryer

    I dunno why , but a torch takes forever
  38. Thread: Txt

    by Snapperhead
    Replies
    24
    Views
    669

    I wonder if the TXV is adjustable .....

    I wonder if the TXV is adjustable .....
  39. Thread: 410

    by Snapperhead
    Replies
    67
    Views
    2,388

    It depends on your taste buds , straight out the...

    It depends on your taste buds , straight out the can its kind of plain , but in a running system after mixing with Poe its much better .... oh and used a fork for best results
  40. Replies
    22
    Views
    905

    Thats CHEATING ! So whats the ill effect ? ...

    Thats CHEATING !

    So whats the ill effect ? Smaller cubes ?
  41. Replies
    14
    Views
    944

    I come across my first TXV stuck wide open last...

    I come across my first TXV stuck wide open last week. Walk-in Freezer 2 yrs old. Got there , heard refrig pouring through coil like crazy , felt coil its warm , Txv warm , Dist tubes warm , im...
  42. Thread: 410

    by Snapperhead
    Replies
    67
    Views
    2,388

    I like the way 410 tastes and smells ....

    I like the way 410 tastes and smells ....
  43. Google , images , is your friend Key words...

    Google , images , is your friend

    Key words compressor , wiring diagram , tecumseh , copeland
  44. Replies
    9
    Views
    474

    I've had great luck just leaving HS210 on for...

    I've had great luck just leaving HS210 on for ever for cheap customers and never had a call back .... but since im selling this unit Id like to make it original

    the 1/3 kit never seems to work...
  45. yea and since the coil is located in freezer you...

    yea and since the coil is located in freezer you really cant use anything else but air sensing

    A30-261 Ranco maybe .....
  46. Replies
    9
    Views
    474

    AEA4440YXA hard start

    So I have a used 2 door True box I wanna sell.

    Got from an auction , so i have no idea of history

    Coil half clogged ofcourse.

    Has the little slip on relay with start cap separate , and one...
  47. Replies
    10
    Views
    303

    why not just throw on a 12-701

    why not just throw on a 12-701
  48. yes , fans stay on , solenoid goes off ...

    yes , fans stay on , solenoid goes off

    someones been in there didnt know what he was doing ....

    have fun straightening that out

    BUT

    make sure that was the thermostat you turned up , and...
  49. Nope , not all techs have soldering irons , only...

    Nope , not all techs have soldering irons , only the Real Techs do ...




    :grin2:
  50. yup , just take the relays cover off and inspect...

    yup , just take the relays cover off and inspect the points. Nothing pops out , no tricks , its Real simple. One screw normally holds the top on. Some like to add a drop of sealant on the screw , a...