  1. Trend IQ TCP Driver in Niagara - IQ3's

    Does anyone know what the Socket Timeout settings for Trend IQ3's are configured in. We are setting up a Niagara Driver and having trouble getting the comm's established. The IQ3's have a Socket...
  2. Why ditch the BCU?

    Why replace the BCU? it seems the easiest approach would be to use the JACE to talk to the rest of the Trane gear (then you don't have to worry about Comm3, Comm4 etc etc) via the BCU (using BACnet)...
  3. Replies
    18
    Views
    1,950

    Fan power

    I agree with Codewriter that it ain't always so that the power saved on compressors is more then the increased fan power! In typical commercial building in Oz (Central AHU's and Chiller Plant, VAVs...
  4. Replies
    12
    Views
    1,583

    Thanks once again for the responses. I agree that...

    Thanks once again for the responses. I agree that the environment and its effect on the wiring connections and control circuitry are really the issue and certainly in my opinion space sensors are not...
  5. Replies
    18
    Views
    1,673

    There I was feeling inadequate at being a plain...

    There I was feeling inadequate at being a plain old "Regular" member, move over I want a Super Pro category now.
  6. Replies
    8
    Views
    2,210

    NAE or JACE

    I will get a proposal from JCI and presumably they willl offer an NAE solution. Thats fine but I am looking at options and the JACE is one of them. By the way you should understand that down here we...
  7. Replies
    8
    Views
    2,210

    DX9100 and JACE AX

    Has anyone had experience connecting a JCI DX-9100 Ver 1 controller to a JACE using the N2 bus. I am considering using the JACE to get visibility of an installation of 2 off DX9100 (standalone, no...
  8. Replies
    12
    Views
    1,583

    Thanks for the feedback gents which pretty much...

    Thanks for the feedback gents which pretty much confirms my thinking on this subject. After working in controls contracting for almost 20 years and now working for a property owner on the other side...
  9. Replies
    12
    Views
    1,583

    Service Life of thermistors

    Does anyone have any thoughts on the service life of 10K thermistors. I was advised recently that the thermistors (space temperature sensors) should be replaced every 5 years....

    I am dubious...
  10. Replies
    3
    Views
    731

    The DP sensor in a VAV controller is measuring...

    The DP sensor in a VAV controller is measuring the velocity pressure with repect to the static pressure. Hence the sampling tube has holes directly in the path of the airflow and at 90 degrees to...
  11. Replies
    57
    Views
    5,127

    Ninax I feel that you give LON far to much credit...

    Ninax I feel that you give LON far to much credit in terms of changing market forces. The low cost install high service cost "model" is more a result of the construction industry way of doing things...
  12. Replies
    57
    Views
    5,127

    A small part of the picture

    mech_head you hit on a point that at times gets overlooked. The technology arguments are but a small part of the picture. Many times comments about this or that technolgy being crap are based on...
  13. Replies
    3
    Views
    699

    Demand VS Consumption

    The pulse output will provide you with power consumption data (KWh) not demand (KW). Changing the KWh per pulse parameter will change the rate of the pulses but won't do anything for your electricity...
  14. Thread: Bacnet

    by adrianfromoz
    Replies
    40
    Views
    3,713

    Auto magic

    The "auto-magic" you describe assumes a network structure that is aligned with the physical ductwork, which is unlikely. BACnet, LON or whatever the development of tools to assist in system...
  15. Replies
    55
    Views
    8,800

    Commissioning

    The last couple of posts have struck a chord with me. We all know the the problem of poor commissioning that continues to dog the industry, it is an discussion that deserves a thread of its own.
    ...
  16. Replies
    5
    Views
    721

    More detail needed

    Bennyk,

    I think you need to spell put a bit more what you're question is. Speaking generically I would say that if you are just using pneumatic actuation then nothing is different between...
  17. Boom Boom

    Smells like a Dorothy Dixer to me! Looking into the future of this thread I see 40 - 50 plus replies, vented spleens, hyperbole plus plus. If you are really looking for solid information good luck...
  18. Replies
    6
    Views
    1,444

    Reference material

    HVAC Controls and Systems - Levenhagen and Spethmann (McGraw Hill)

    The Honeywell Grey Manual is a very comprehensive reference and a deifinite must have.
  19. Replies
    3
    Views
    632

    Good Luck!

    The short answer is NO. The longer answer is that as a physical communications layer LON may comply but there's no way you would be sending BACnet packets down a LON wire.

    So I would be looking...
  20. Replies
    2
    Views
    554

    Contactors

    Nhilar,

    I think for that sort of load you really would be best advised to install a contactor to switch the load and use any standard thermostat to switch the control line to the contactor. If you...
  21. Replies
    15
    Views
    2,526

    Remote Diagnosis

    A note of caution particularly for those new to controls. While I have no reason to doubt Integrator's skills and technology has given us great options for remote diagnosis, there is no substitute...
  22. Replies
    4
    Views
    796

    Glad to be of help! Stay cool, not that you've...

    Glad to be of help!

    Stay cool, not that you've got any choice in the wrong half of the world!
  23. Replies
    4
    Views
    796

    Port 1 is the main air supply from the air...

    Port 1 is the main air supply from the air station and Port 3 goes to the mains controls for the Air Handler. When de-energised the the mains air to the control circuit bleeds out through port 2 and...
  24. Check the register address base

    Your'e problem may be that the address you are using is out by one. For example the client device may have its address map start at 1 but the master device assumes a base of 0. This is a problem that...
  25. Replies
    6
    Views
    1,680

    Learn the BCU

    qtip is correct, using JDE (if using R2 Tridium) or AX quivalent you can learn the BCU and this will give you all the AI, AO, BO and BI. It is very straight forward. You should only need the Network...
  26. Replies
    9
    Views
    1,209

    Thanks

    Thanks for the info, the reference http://tristate.apogee.net/cool/cxfrc.asp
    helps. I am going to get the original specification soon so hopefully I can get to the bottom of exactly why series...
  27. Comms and Signal resistors

    I agree with javajunkie that these are your're most likely answers. A word of warning with regards using a 500Ohm resistor to convert 4-20mA to 2-10vdc. Current drivers are designed to connect to a...
  28. Replies
    8
    Views
    2,400

    Decoupled Systems

    The following Trane engineers newsletter gives a good overview of decoupled systems:

    http://www.trane.com/commercial/library/vol18_2/en18_2.pdf

    The Eagle-eye is a flow sensor and needs to be...
  29. Replies
    9
    Views
    1,209

    Series Chillers

    Does anyone have any general information on the sequencing / control of a series chiller plant confuration. This is an unusual configuration here and I have only ever seen it once previously a long...
  30. Replies
    23
    Views
    2,619

    BACnet Compliance

    Hi there,

    The BACnet standard does not address what is to be made available but how it is made available. This is both a strength and a weakness of the standard. It was meant to allow maximum...
  31. Replies
    17
    Views
    4,071

    BACnet / LONworks?? who really cares....

    I'm constantly amazed reading this forum at the obsession that continues over the BACnet / LONworks war in North America. Surely by now we should be educating our clients to move on and concentrate...
  32. Controls for Package AC Units

    yp5,

    I reckon there is any number of simple controllers that can do the job reliably. In Australia Innotech are very poular for simple, programmable stand-alone DDC controls. I think that the...
  33. Replies
    1
    Views
    2,642

    Stultz C7000 Modbus Gateway

    Hi there,

    Does anyone have modbus register info for a Stultz C7000 modbus interface.

    Regards
    AdrianM
  34. I have found that doing a printscreen and pasting...

    I have found that doing a printscreen and pasting into Paint Shop Pro works fine. I then save as a GIF with transparency. As the background colour of the DWG files is often black you will need to...
  35. Replies
    3
    Views
    2,518

    Thanks for the replies, I have found a couple of...

    Thanks for the replies, I have found a couple of US suppliers of convertors. I have tried to search Siemens site without a great deal of luck.

    Am reluctant to go down the path of throwing the 50+...
  36. Replies
    3
    Views
    2,518

    Phase Cut Signal

    Can anyone enlighten me on phase cut control signal as used on Staeffa valves. I have not previously come across them until looking at a refurb project recently. Are 0-10/4-20 to phase cut...