  1. While the wiring may be very similar, and the...

    While the wiring may be very similar, and the temperature sensing element is the same (20K-NTC), you will have problems with the setpoint (CPA (control point adjustment)). Your existing T7412B1008...
  2. Replies
    5
    Views
    304

    I'd also try re-addressing en1 on the JACE to...

    I'd also try re-addressing en1 on the JACE to something other than .1 - it's possible that the FG32 has been inadvertently configured with 192.168.10.1 as its default gateway, and -might- be choking...
  3. Replies
    17
    Views
    1,297

    Wow, brockers, you guys work fast - write a cool...

    Wow, brockers, you guys work fast - write a cool piece of code, and make a nice-looking webpage with a link...good stuff.
  4. Replies
    6
    Views
    373

    Similarly, I often use a ComponentGrid (within...

    Similarly, I often use a ComponentGrid (within the report palette) to build a quick grid of various points within identical controllers, and all the actions are available on any points displayed in...
  5. Replies
    19
    Views
    4,312

    Be careful - I might take you up on that! ...

    Be careful - I might take you up on that!

    You've got mail.
  6. Replies
    9
    Views
    623

    Yep, those points are pretty nice for a...

    Yep, those points are pretty nice for a trim-and-respond input. They will be either a 0 or a 1 - map them into the JACE from all of your VAV's, count up how many are 1, and reset your setpoints up or...
  7. And for the opposite perspective: I tend to like...

    And for the opposite perspective:
    I tend to like large wiresheets, where I can click on a link and then pan around the wiresheet with the thumbnail, and actually find the link's destination, as...
  8. Thread: R2 Neuron IDs

    by davem
    Replies
    6
    Views
    356

    You won't be able to see the list by looking at...

    You won't be able to see the list by looking at an offline version of the station - I'm pretty sure you've got to be looking at a live station.

    The list of connected LON devices in within the...
  9. Replies
    11
    Views
    669

    I will certainly agree with that...I just think...

    I will certainly agree with that...I just think that the OP has little choice but hope that his Honeywell distributor is as responsive as he needs them to be.
  10. Replies
    11
    Views
    669

    Working as I do for one of the "distributor...

    Working as I do for one of the "distributor donkeys", Orion has it exactly right (well, mostly right) - our tech support is expected to triage the questions first (unlike the nature of most of the...
  11. Replies
    9
    Views
    623

    RozekJT had your solution above - use an...

    RozekJT had your solution above - use an EnumSwitch (available in the kitControl>Util palette), and configure its true and false values to whatever the enum is for the HeatingEnabled point......
  12. The GX1's are likely running an internal SPL...

    The GX1's are likely running an internal SPL program, that may or may not be writing those setpoints to itself. To check if this is the case, map in the F201;$$ attribute, and set it to 0 (Stopped)...
  13. I've used the driver a couple times, and while it...

    I've used the driver a couple times, and while it was slow (really, really slow), it successfully connected to every "cabinet" on the network through a single connection to an MBC/MEC. Either...
  14. Replies
    8
    Views
    954

    I agree with Igotworms - setting up the BBMD is...

    I agree with Igotworms - setting up the BBMD is overcomplicating this: as long as the BACnet/IP port is enabled, and BACnet Routing and Maintain Routing is enabled, you'll have no problems connecting...
  15. Replies
    6
    Views
    431

    I can get you the manuals, even for the Sage, but...

    I can get you the manuals, even for the Sage, but it will definitely require some terminal time on the Sage to get all the information you need for a successful integration. Understanding how...
  16. Replies
    1
    Views
    332

    Up in the Services, if I remember correctly, is...

    Up in the Services, if I remember correctly, is the LonWorks Service - within there, you'll be able to discover new LON devices, etc., etc...
  17. Hmmm, so you conveniently whitewash the actual...

    Hmmm, so you conveniently whitewash the actual difficulty of this issue by first ignoring the real-world variables with a "common average", whatever that is, then claim that trial-and-error will...
  18. Replies
    3
    Views
    359

    Yep, the "Load" in the diagram is indeed the VFD....

    Yep, the "Load" in the diagram is indeed the VFD. Run a 24VDC source from VFD terminal 12 or 13 to the + on the transducer, run the negative of the transducer (the actual 4-20mA signal) to VFD...
  19. Depending on how often you have been writing to...

    Depending on how often you have been writing to the Daikin system, you may have inadvertently roached it - from Daikin's BACnet Gateway Design Guide:
    "The system is designed to keep the memory of...
  20. Replies
    19
    Views
    4,312

    You've got mail, Rick...

    You've got mail, Rick...
  21. Replies
    8
    Views
    516

    Mail sent.... I think you're really in a world...

    Mail sent....

    I think you're really in a world of hurt with those TX1s...they are so application-specific that I don't believe there's a way to tell the control loops to look at another input for...
  22. Replies
    8
    Views
    516

    If you put your email address in your profile, I...

    If you put your email address in your profile, I can send you the book for the TC1.
  23. Replies
    8
    Views
    516

    Which VAV controller are you working with? TX1?...

    Which VAV controller are you working with? TX1? TC1? SBC-VAV?
  24. Replies
    6
    Views
    1,037

    Such a zoning system has already been built by...

    Such a zoning system has already been built by someone on Johnson's Connected Community - there are config files available for the RTU, the zone controllers, and video files detailing how to set it...
  25. Or see if you can purchase the Cleaver-Brooks...

    Or see if you can purchase the Cleaver-Brooks Protonode (a Fieldserver product), which comes preloaded with the profiles for most CB equipment. Use Fieldserver's free software to set it up for the...
  26. Thread: Open protocols

    by davem
    Replies
    40
    Views
    5,326

    Isn't that 6? :grin2: Which one should I leave...

    Isn't that 6? :grin2: Which one should I leave out? :whistle:
  27. Thread: Pcg1611 fault

    by davem
    Replies
    10
    Views
    828

    SAB is the Sensor Actuator Bus, referring to...

    SAB is the Sensor Actuator Bus, referring to sensors that are wired to the SA Bus terminals on the controller.
  28. Thread: Pcg1611 fault

    by davem
    Replies
    10
    Views
    828

    With the controller programmed like that, you...

    With the controller programmed like that, you probably had to modify the default zone sensor signal from SAB to whatever resistive sensor you are using. Doing so would have removed the SAB setpoint...
  29. Thread: Pcg1611 fault

    by davem
    Replies
    10
    Views
    828

    Just to clarify the issue a little further: if...

    Just to clarify the issue a little further: if the zone sensor is a networked sensor (as opposed to something wired to one of the universal inputs), you should have something wired to the SA bus, but...
  30. Thread: Pcg1611 fault

    by davem
    Replies
    10
    Views
    828

    The problem may lie within the program - if the...

    The problem may lie within the program - if the program is expecting to see a networked zone sensor, that's one reason for the fault light to be on. You'd have to know how to use the PCT software to...
  31. Thread: Pcg1611 fault

    by davem
    Replies
    10
    Views
    828

    Does the .caf file contain references to any...

    Does the .caf file contain references to any networked sensors or PCX modules that aren't wired up?
  32. Replies
    9
    Views
    1,599

    Are you sure that the units are Comm4, not Comm3?...

    Are you sure that the units are Comm4, not Comm3? In my Intellipaks, I had to rotate the comm card and set a couple dipswitches for it to talk Comm4...I don't know about the comm cards in your...
  33. Replies
    9
    Views
    1,599

    I had a Comm4 job (with Maxline's driver), with...

    I had a Comm4 job (with Maxline's driver), with Intellipaks, that required the addressing to be above 32...so you may need to readdress the equipment...I can't remember if this was unique to the...
  34. Ditch the Auto-Pilot installation (and that...

    Ditch the Auto-Pilot installation (and that ancient SF1), and move the existing PUP network to a JACE...with a maximum of 32 devices per SF1, there can't be that much for a Tridium contractor to cut...
  35. Replies
    2
    Views
    501

    The kitPx palette contains an "EnumImage", in...

    The kitPx palette contains an "EnumImage", in which you can ord an Enum point, and select an image for any of the Enum's ordinal values.
  36. Not sure if you've got this document, but...

    Not sure if you've got this document, but starting on page 3, there's a pretty good definition of what each point does. If the Hub was set up with "scenes", you may not get quite the manual-control...
  37. Replies
    33
    Views
    4,563

    The 37 hours straight on a central plant...

    The 37 hours straight on a central plant cutover...no, just kidding - definitely the variety. That's what appealed to me most when I transitioned from commercial electrical work into controls -...
  38. Replies
    1
    Views
    514

    I didn't think Auto-Pilot could email...the most...

    I didn't think Auto-Pilot could email...the most sophisticated alarming I ever got working was sending custom text over a modem to an alpha-numeric pager...I don't think SageMAX/IP's could connect to...
  39. Replies
    4
    Views
    1,224

    Make sure an SD card is installed in the FG20 -...

    Make sure an SD card is installed in the FG20 - without it, you won't be able to install the firmware onto the FG20.
  40. Replies
    15
    Views
    12,908

    That manual is great - thanks for posting that!...

    That manual is great - thanks for posting that! I'd always wondered where to set a JCI VAV controller for various box sizes - I've had a Titus sheet with the "cfm @ 1"w.c." figures for awhile, that...
  41. I agree with Dansky (if I grasp what he's...

    I agree with Dansky (if I grasp what he's saying): this is all on the Lutron guy. For instance, on a job I was just on, the Lutron guy setup with the panels on each floor with the IP address I...
  42. Replies
    8
    Views
    998

    The PNC post-dates my AAM experience by several...

    The PNC post-dates my AAM experience by several years - although I see you work straight for AAM, and I haven't been an SI for almost 10 years, any chance I could send you the point.bob file for...
  43. Replies
    8
    Views
    998

    Thanks for that - while mildly sentimental to...

    Thanks for that - while mildly sentimental to look at, it turned out that the disk didn't have such a utility - which keeps me in the hunt for how to drag out the points list from a Sage into a...
  44. Replies
    8
    Views
    998

    Groovy - thanks! For some reason I found a...

    Groovy - thanks! For some reason I found a SageMax 1.8 IP setup disk on my laptop, but not the Utility disk...funny the old crud we keep around...(and then need the instant we throw it away...)
  45. Replies
    8
    Views
    998

    A little AAM conversion help, please!

    I've got a customer who is going to remove a SAGE from an end-user's facility, and replace it with a JACE. Having done several of these over the years, I know exactly what he needs to do to make a...
  46. Replies
    3
    Views
    586

    I think incontrol is looking for the information...

    I think incontrol is looking for the information to be available on the logic wiresheet, not necessarily a px page - that was a very handy feature of r2 wiresheets...
    What you need to do is...
  47. Replies
    14
    Views
    2,476

    That might be where you are slightly off-course -...

    That might be where you are slightly off-course - you won't be using the Program Service for this replace function:
    Make sure you're in Niagara Network>your JACE>Points>your new folder...that's...
  48. Replies
    14
    Views
    2,476

    Incontrol, you must be missing a step, because...

    Incontrol, you must be missing a step, because this process works perfectly...

    Make sure when you open the rtu4 folder, you then select all its points, then Edit. When the Edit dialog opens up,...
  49. Replies
    5
    Views
    865

    Mmelillo beat me to it - yes, I recommend option...

    Mmelillo beat me to it - yes, I recommend option 3, as it makes the temperature widgets a little more controllable (if you were to animate the Visible slot, as in option 1, and the binding condition...
  50. Replies
    5
    Views
    865

    Now that I've re-read the post, I see that I...

    Now that I've re-read the post, I see that I answered your first version of the question ("...based on the status of the controller...), but changing the image based on the reliability of the zone...
Results 1 to 50 of 524