  1. Charging a Trane Mode # SWUD Commercial Air Handler Unit

    Hello I recently became a building engineer (I was a residential service technician) and I have to charge a 15 ton compressor that holds 27lbs of refrigerant. This is new to me as I am use to...
  2. Replies
    3
    Views
    358

    Thanks for the info ControlsinMT I am actually in...

    Thanks for the info ControlsinMT I am actually in the process now and submitted my application for pro. Just waiting to hear back from the administrator.
  3. Replies
    3
    Views
    358

    Question about charging a unit

    I have a question about charging a large commercial hvac unit. I have now become a commercial building engineer at this point of my career (I was a residential hvac technician) and notice that these...
  4. Replies
    8
    Views
    495

    Removing filter drier properly

    Just a question about removing a filter drier. Do you techs think it is better to cut the filter drier off with tubing cutters or just unbraze it directly off the coupling? I have heard it is bad to...
  5. Replies
    0
    Views
    267

    Questions about NIULPE License

    I recently got my NIULPE Class 4 Power Engineer's license. Does it have any actual worth?? I'm trying to get my DC 3rd Steam Engineers License but I was wondering what you all think about NIULPE.
  6. Replies
    1
    Views
    335

    Well I finally figured out what this is....it is...

    Well I finally figured out what this is....it is a relief valve to prevent overcharging the system with refrigerant. This is a commercial Air Handler Unit and holds around 100 lbs of refrigerant (4...
  7. Replies
    1
    Views
    335

    Trane package air handler unit

    I have a question, I noticed my compressors in my air handler units have some type of relief valve connected to the hot gas discharge line leaving the compressor. It tee's off to another copper line...
  8. What does the 2nd TXV in a heatpump in heating mode do?

    I was wondering what the TXV going into the condenser does when the heatpump is in heating mode. I know the evaporation coil has hot gas and is subcooled by the cold it absorbs, so it returns to the...
  9. Question about removing acid from a system when a compressor burns out

    Hello I have a question about what is the best way to remove acid from an ac system. I usually install a suction line filter drier after replacing the acidic oil with fresh new oil and have to return...
  10. Question about Water Source Heatpumps

    Hello, I have a question about charging water source heatpumps. I have a lot experience charging air-source heatpumps but none with water source. My question is this: How do I know if I have a proper...
  11. Replies
    2
    Views
    408

    CFM Question

    I have a customer that wants to install 2 kitchen hood grills, there currently is a 22"x20" base building grease duct for future tenants. What would be the maximum amount of CFM you could put in that...
  12. Replies
    7
    Views
    357

    Thanks

    Thanks you're right hvacsolutions won't help them is time, but I will recommend to the owner to install tint. I'll look at the 3M. Thank you.
  13. Replies
    7
    Views
    357

    Airflow in Restaurant

    Hello I have a question. I went to a restaurant that doesn't get enough cooling in the area near the windows facing the street. They have no blinds or tint so when the sun is out the front part of...
  14. Replies
    9
    Views
    615

    Question about commmercial unit

    I was working on an hvac unit at a restaurant and the units don't seem to be keeping up with the load the restaurant has when it is full. There are around 70 people and the place is 77 degrees. My...
  15. Replies
    18
    Views
    1,418

    Makeup air unit....

    I have a question, doesn't an outside makeup air unit just bring in hot air in the summer? I know the makeup air unit helps when more air is needed but doesn't it make the space even hotter? I would...
  16. Replies
    4
    Views
    487

    Question about a kitchen hood

    I went to a restaurant yesterday because they complained the temperature in the restaurant and I noticed the restaurant is in a huge negative static pressure, the doors will not close from so much...
  17. Replies
    10
    Views
    395

    Also I would think the engineer that designed the...

    Also I would think the engineer that designed the cabinet would add that U shaped heating element to prevent condesation from accumulating in the pan as it has, why don't they just put an element in...
  18. Replies
    10
    Views
    395

    Thanks ECtofix you got it right, I see a pleated...

    Thanks ECtofix you got it right, I see a pleated "wick" acutally about 5 wicks in order in the pan but it just seems so odd that the pan would be full to the brim. I would expect the wick to...
  19. Replies
    10
    Views
    395

    Question about reach in cabinet

    Today I was looking at a reach in cabinet that stays around 40 degrees constantly. The problem is not the temperature but I noticed the condensate pan does not have a heating element that evaporates...
  20. Question about static pressure in a restaurant

    Hello, I was at a restaurant today and the restaurant is in a big negative. The doors won't even close due to such negative static pressure. The original mechanical contractor did not install a...
  21. Replies
    1
    Views
    927

    R 421 A Refrigerant

    What do you guys think of this new R421A refrigerant that is much cheaper than R22 ? Does it work just as good? Just wondering if anyone has used it since I am considering using it since it is half...
  22. How to charge a vending machine compressor

    Hello everyone the question I have is this: A guy wants me to charge his vending machines, but I have never charged vending machines. What is the best way to charge vending machines properly? I know...
  23. Low coolant can do a few things, first it can...

    Low coolant can do a few things, first it can overheat your compressor but your compressor probably has an internal overload so your unit will just cut off when it begins to run and starts to get too...
  24. Reach in drain pan keeps filling up with water

    Hello I'm working on a reach in and the drain pan just keeps filling up with water. The inital problem was that the heating element shaped like a W was full or rust, it's an old unit. I cleaned the...
  25. what if there already is refrigerant in the...

    what if there already is refrigerant in the system, is there a way of just adding instead of recovering it all and putting it back in? it's a cap tube style system.