    My suggestion: bring the person that smells the...

    My suggestion: bring the person that smells the gas outside. Crack a union, slightly and have them take a whiff, make sure it's gas that he/she actually smells. It's a little unoethodox, but if...
  2. Replies
    17
    Views
    1,987

    theres is also a chance that the pilot is weak...

    theres is also a chance that the pilot is weak and not reaching the burner when when the valve energizes.
  3. Replies
    13
    Views
    1,477

    Any licensed refrigeration mechanic can do it,...

    Any licensed refrigeration mechanic can do it, they teach us how to wire a freezer in trade school. The only tricky part I found was trying to keep the "evap fan off when the door is open" feature. ...
  4. Replies
    13
    Views
    1,477

    Those microprocessors are expensive and...

    Those microprocessors are expensive and cheap...if you know what I mean. They will work for about a year or so, then start doing the same thing. I've had the same problem in the past, where the...
  5. Replies
    6
    Views
    778

    I'm not sure if it was a koldpak, but I got to...

    I'm not sure if it was a koldpak, but I got to cut one out once on a Saturday night emergency service call once. It was leaking and tightening it only meant I'd be fixing it again. The freezer was...
  6. Replies
    6
    Views
    1,790

    try the residential forum, you may have better...

    try the residential forum, you may have better luck.
  7. Replies
    5
    Views
    1,141

    That was the only conclusion I could come up with...

    That was the only conclusion I could come up with too. It's just strange that BOTH circuits are doing it. I'll pump one down, replace the drier, evacuate and test again. Thanks for the input guys.
  8. Replies
    5
    Views
    1,141

    The system is a 50 ton refer unit with r22. Each...

    The system is a 50 ton refer unit with r22. Each circuit is independent with 25hp semis. Both have sight glasses that are flashing. Both have 15F subcooling. How is this possible? I took the...
  9. Replies
    30
    Views
    3,437

    Just a thought...Is the new motor a condenser fan...

    Just a thought...Is the new motor a condenser fan motor? Sometimes they will have all the same data, but will overheat as they are an "air-over" motor. This meaning that they use the air drawn...
  10. Replies
    37
    Views
    13,953

    hey Dave.. I appreciate your insight on this...

    hey Dave..
    I appreciate your insight on this subject. No worries though, I never once took anything he said to be factual. You're obviously well trained in this trade and I think everyone who...
  11. Replies
    4
    Views
    804

    My GUESS is: the nickel is worn off of the evap...

    My GUESS is: the nickel is worn off of the evap and the ice is sticking to it during harvest.
  12. Replies
    37
    Views
    13,953

    Thanks guys...and er ..uh "2 seasons employed"...

    Thanks guys...and er ..uh "2 seasons employed" for your responses!
    I installed the unit today and used 404, almost a full jug!
    It is working great. I'm going to check on it tomorrow just to...
  13. Replies
    37
    Views
    13,953

    Hey Lusker...thanks for the reply The compressor...

    Hey Lusker...thanks for the reply
    The compressor comes with POE oil in it already. The unit has all the bells and whistles for low ambient capacity control too. I was just curious what some guys...
  14. Replies
    37
    Views
    13,953

    I'm installing a new air cooled 5hp outdoor...

    I'm installing a new air cooled 5hp outdoor condensong unit with capacity control tomorrow. It was originally a water-cooled 3hp unit, that had R408 dropped into it about 4 years ago. The condenser...
  15. Replies
    4
    Views
    783

    looks like a 5-ton armstrong, i think the 15 is...

    looks like a 5-ton armstrong, i think the 15 is actually 150, indicating the heating capacity in btu's
  16. Thread: BC Wages

    by jeffcolledge
    Replies
    2
    Views
    799

    I know we're not supposed to ask about...

    I know we're not supposed to ask about wages...but I'm curious if the wages in BC are comparable to Ontario. Could someone please give me a link to a website, I'm having trouble finding the info. ...
  17. Replies
    12
    Views
    986

    Ok, so you think after defrost, the system is...

    Ok, so you think after defrost, the system is flooding liquid, washing out the oil and failing on oil pressure? That makes sense to me, except the high discharge temp. Could you explain that one?...
  18. Replies
    12
    Views
    986

    They only run the blast in critical times, like...

    They only run the blast in critical times, like this, it rarely runs. Sometimes when they are doing a lot of production and they are in and out of it, they will run it too. They have a temp....
  19. Replies
    12
    Views
    986

    Well, he said they were both tripped all three...

    Well, he said they were both tripped all three times and they were both tripped today. I got to believe it's an oil problem and not a compressor problem at this point. I'm thinking piping may be a...
  20. Replies
    12
    Views
    986

    Ice... Thanks for the reply... Pumpdown lpc...

    Ice...
    Thanks for the reply...

    Pumpdown lpc are working.
    Contactors are good, oil failure is 240 volt, inseries with coil, compressor is 600volt
    Watched both compressors for 3 hours, with a...
  21. Replies
    12
    Views
    986

    Two carlyle 06d compressors twinned together with...

    Two carlyle 06d compressors twinned together with a common oil line between them. The application is a walk-in freezer maintaining below 0F using R507 & POE oil. Thermostat/defrost control is a...
  22. Replies
    15
    Views
    1,304

    There are two 3000lb Maja units and one 3000lb...

    There are two 3000lb Maja units and one 3000lb Howe I was told they were 25 hp, the model # are 06ey450-140. I'ts working great now with both of them working. Thanks for the input!
  23. Replies
    1
    Views
    1,006

    Why are you replacing it? I've pulled them out...

    Why are you replacing it? I've pulled them out and repaired leaks, replaced motors and cleaned them before.
  24. Replies
    10
    Views
    1,071

    Wow R12, I think you covered all the bases! The...

    Wow R12, I think you covered all the bases! The only thing I could add to that is...are you sure the time clock is working? Set it to the exact time next time you're there, and come back again at...
  25. Replies
    15
    Views
    1,304

    Yeah, it makes 9000lbs/day!

    Yeah, it makes 9000lbs/day!