  1. To test the TXV actally place the sensing buld in...

    To test the TXV actally place the sensing buld in a cup with ice then warn it up just to determinate if the valve is responding, if the valve is stuck wide open like you are suspecting, why the...
  2. OT 50F , suction is a way high, remove the...

    OT 50F , suction is a way high, remove the sensing buld and warm it up, with ur hand that should start to close the TXV, IF it does not, valve need to be repraced or the head.

    Also due the the...
  3. Replies
    17
    Views
    1,813

    Delta T across the coil is kind of high, it could...

    Delta T across the coil is kind of high, it could be due to low air flow, and someone charged the system by pressure only, pressure low oh yes more refrigerant and more and mo:gah:re till it gets...
  4. Replies
    15
    Views
    6,418

    Is it a chilled water AHU? Few week ago I...

    Is it a chilled water AHU?

    Few week ago I went to a service called, I found one of the fuse blown, the costumer told me that it wasn't the first time this happened,

    The issue had been ...
  5. Replies
    97
    Views
    5,379

    have the tranformer been replaced? maybe the VA...

    have the tranformer been replaced? maybe the VA ARE TOO SMALL , LOOSE OR RUSTY CONECTION SOMEWHERE
  6. Replies
    12
    Views
    2,985

    yeah thats true.Good point

    yeah thats true.Good point
  7. Replies
    12
    Views
    2,985

    with a axu 2 pole relay,kill the common of the...

    with a axu 2 pole relay,kill the common of the fan and in the other contactor the yellow wire for cooling
  8. Replies
    47
    Views
    5,688

    INTECBILL; IF the condenser is restricted the...

    INTECBILL; IF the condenser is restricted the high pressure 'll increaes as well the compressor amps drawing , due to that , the widing temp 'll raise and the compressor overheats , but that...
  9. Replies
    26
    Views
    2,148

    normally the dip switches have one for cool and...

    normally the dip switches have one for cool and other one for heat mode
  10. make sure he , set the dip swicthes rigth , to...

    make sure he , set the dip swicthes rigth , to mach out door unit.the grill siza is can of small too.
  11. Replies
    9
    Views
    2,480

    just check on post #2 its already explained over ...

    just check on post #2 its already explained over there, why this happens / and the unit was a 2 ton corfort tech , the piston i think it was 23 i dont remenber but it definely was a lot smaller...
  12. Replies
    9
    Views
    2,480

    belive it or not the orifice works like this ...

    belive it or not the orifice works like this larger piston = lower suction and higher head pressure, and smaller piston higher suction pressure and lower head pressures (in the same size evap), the...
  13. Replies
    9
    Views
    2,480

    ok now it has sence , thanks a lot for ur help,...

    ok now it has sence , thanks a lot for ur help, one more last thing with a larger piston the suction pressure gets lower so I think if I AM not wrong , what happens in this case the refrigerant ...
  14. Replies
    9
    Views
    2,480

    oh and other thing ,was than the liquid line with...

    oh and other thing ,was than the liquid line with a lower high head pressure felt warmer? I dont get it
  15. Replies
    9
    Views
    2,480

    thanks, that is what I was thinking about the low...

    thanks, that is what I was thinking about the low side but i could not understand what was happening with the high side, now has sence thanks for ur help. what i dont get is why like u said smaller...
  16. Replies
    9
    Views
    2,480

    fix orifice question?

    hey guys , I got a called the other day , costumer reported outdoor unit making a huming noise , I arrived to the place ,there was a little huming noise in the compressor , not too loud and I ...
  17. Replies
    38
    Views
    3,567

    my bad !! lol

    my bad !! lol
  18. Replies
    38
    Views
    3,567

    a high leg won't affect the compressor in three...

    a high leg won't affect the compressor in three phase system , check the rotation,must of 5 ton system have a single face motors. how was the pressures? was the compressor noise after stared it up?
  19. Replies
    61
    Views
    3,215

    he changed the coil and few days later he found a...

    he changed the coil and few days later he found a obstruction in the dryer, if he service it right the first day that would not ever happend . that seens to me just a bad installation and the tech...
  20. i have done it , more like small refrigeartion...

    i have done it , more like small refrigeartion aplications , when i dont have a label plate with amount of freon , but also checkin TD and pressures at the same time , this its just to make sure...
  21. Replies
    36
    Views
    1,546

    the manual will tell the min cfm for ur ahu, but...

    the manual will tell the min cfm for ur ahu, but u deffinily have to check the system 's pressures. the compressor could be flooding with liquid freon and not necesary icing up at the evap.
  22. some times what happends the drain is not glogged...

    some times what happends the drain is not glogged its just than the drain line gets air lock specially the ones that coming under the house, cause makes like a kind of p -trap , put some water in...
  23. Replies
    18
    Views
    2,035

    does the fan seen that is working full speed?...

    does the fan seen that is working full speed? .... are the fan motor and fan blades originals or they have been replaced? I had a problem like that and the fan blade some other tech had replaced it...
  24. Replies
    8
    Views
    2,266

    yeah it can fail totally closed , if the gas in...

    yeah it can fail totally closed , if the gas in the sensing bulb leaks out , we need more info to help u out, is this system a dual system or single system?
  25. Replies
    32
    Views
    5,125

    THE FIRST TECH ADDED FREON AND THEN HE SAID THE...

    THE FIRST TECH ADDED FREON AND THEN HE SAID THE PRESSURES IS TO HIGH , HUH ? YEAH IT SOUNDS LIKE A TXV PROBLEM , I WISH WE CAN KNOW THE PRESSURES READING.