Search:

Type: Posts; User: johndief

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    704

    He wanted to replace all the equipment he had...

    He wanted to replace all the equipment he had with new stuff.
  2. Replies
    9
    Views
    704

    Meat Packing Plant

    Small meat packing plant in rural area literally in a town with 10 houses. Open drive units serves the cutting room. Copeland semi does the freezer. I did not know if I should put this is WOS or WOP....
  3. Replies
    10
    Views
    792

    You are correct.

    You are correct.
  4. Thread: Fried

    by johndief
    Replies
    13
    Views
    991

    Yep

    Yep
  5. Replies
    10
    Views
    792

    She got the machine from us but didn't want us to...

    She got the machine from us but didn't want us to install it. Took about 4 weeks to get it dried out. It actually was a good shop project, we learned that just leaving the vacuum pump running...
  6. Thread: Fried

    by johndief
    Replies
    13
    Views
    991

    Fried

    Looks like relay caught on fire to me.
  7. Replies
    10
    Views
    792

    This is not a water line

    Plumber hooked up new ice machine. Not sure what he thought the stuff coming out was when he hooked it up was. He realized he messed up and brought someone in to "suck out" the water. The person that...
  8. Replies
    4
    Views
    392

    LED Lights In Fresh Meat Case

    I have a customer that is interested in putting LED lights in a meat fresh meat case, local electrical supply house not sure what bulb to use. The florescent bulb the customer was using were a...
  9. Thread: tech

    by johndief
    Replies
    10
    Views
    805

    I just had one of those units a few mounths ago...

    I just had one of those units a few mounths ago that would freeze in the bin. Agitator is suposed to come on for .6 sec for every 12sec of dispence time. Relay on
    board was bad and not bringing on...
  10. Replies
    10
    Views
    2,063

    Time to turn thermostat off of cooling

    Working on a walk-in cooler at a mall for another customer, made mall office aware that this unit needs attention.
  11. Replies
    4
    Views
    817

    No i didn't get any cake, I think it was there...

    No i didn't get any cake, I think it was there for awhile.
  12. Replies
    4
    Views
    817

    Traulsen Overhaul

    Old Traulsen case in a church kitchen, literaly only used on sundays by little old ladys. Box and doors in great shape. R-22 refrigeration system had leaking evaporator and bad compressor. Overhauled...
  13. Replies
    9
    Views
    1,626

    It is not a code in our area to have to pipe to...

    It is not a code
    in our area to have to pipe to the roof drain, but some owners like it that way. We did not do this install so I don't know who decided to do it this way. I think there was plenty...
  14. Replies
    9
    Views
    1,626

    Filter Doors Blocked

    (3) brand new Trane 15 ton rooftop units on brand new resturant. Filter access doors blocked by drains on all of them.
    Ice machine piping not correct. Beer tap fan wrong direction. Not someones best...
  15. Replies
    10
    Views
    1,426

    I think it was easier to get the check valves...

    I think it was easier to get the check valves than to get txvs, cheeper too I think. I have not tried internal check valve txv on hot gas defrost cases. Does it work well? That would save some piping.
  16. Replies
    10
    Views
    1,426

    (7) New magna checks are working like a dream....

    (7) New magna checks are working like a dream. CoreSense seemed to trip on oil pressure before comressors were damaged. Rack had digital Discus that did not trip it did not seem to get slugged as bad.
  17. Replies
    10
    Views
    1,426

    Not sure what brand, but they were take apart...

    Not sure what brand, but they were take apart angled spring checks. The piston was getting hung up on the bottom threads.
  18. Replies
    10
    Views
    1,426

    Bad Check Valves

    (7) brand new check valves on used display cases converted to hot gas would
    stick after defrost. New low temp rack was taking a slug.
    It would take about 3 hours after the late night defrost for...
  19. Thread: IS it me?

    by johndief
    Replies
    3
    Views
    583

    If the compressor has POE oil or can be changed...

    If the compressor has POE oil or can be changed to POE oil I would use R-404A.
  20. Thread: IS it me?

    by johndief
    Replies
    3
    Views
    583

    The r-12 zp head on the txv will not allow your...

    The r-12 zp head on the txv will not allow your suction pressure to go above its mop of 12 lbs. if it it a r-502 compressor i would remove the charge and discard it, replace the valve with a properly...
  21. Replies
    2
    Views
    364

    I dont know i will have to look again.

    I dont know i will have to look again.
  22. Replies
    2
    Views
    364

    Samsung-Turbo-Air

    Anyone have a cross referance for samsung compressors Mo# 3R1A1C-LW2 Samsung siite has nothing
    google was not any more helpfull.
  23. Thread: Opinion

    by johndief
    Replies
    11
    Views
    931

    I did one years ago with 3 thermostats and one...

    I did one years ago with 3 thermostats and one seven day time clock. Every 12 hrs it switched from one unit to the other. both system tstats were set the same co 35 ci 40. Third tstat was an override...
  24. You do not have to remove all the refrigerant to...

    You do not have to remove all the refrigerant to charge to the sporlan chart. Clear the sight glass first. Then add the refrigerant per the caculations from the chart to add refrigerant needed to...
  25. Replies
    5
    Views
    1,812

    Distributors are inexpensive and easy to install....

    Distributors are inexpensive and easy to install. Sporlan guy sized it and a txv for me. No reason not to do it right.
Results 1 to 25 of 172
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image