Search:

Type: Posts; User: SoFlaDave

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    16
    Views
    606

    The modules from the Gentech Evergreen motor work...

    The modules from the Gentech Evergreen motor work great too and often are the same price or less than the OEM module alone and available at pretty much every supply house. Match the HP of course....
  2. Thanks Timebuilder, that's the most concise...

    Thanks Timebuilder, that's the most concise description anyone has laid out on that topic. Basically the 180 degree phase difference can only be considered an inversion and not a separate phase...
  3. Replies
    30
    Views
    732

    Drill to the center of the earth and make peace...

    Drill to the center of the earth and make peace with the subterranean lizard people in hopes that they will help us overthrow the Obama administration so we can finally get REAL president?
  4. Replies
    30
    Views
    732

    No the question is, why is this posted in a...

    No the question is, why is this posted in a technical forum?
  5. Apologies to the OP for the derailment. The...

    Apologies to the OP for the derailment. The importance of understanding electrical theory can't be overstated in this trade, so keep it up. Sometimes the difference between a good tech and a great...
  6. If you were to take a voltage reading between...

    If you were to take a voltage reading between capacitor common and the " run" side of the contactor, what would it read?
  7. Other than the obvious function of providing...

    Other than the obvious function of providing power to the the fan and herm terminals there is nothing that can be done on the capacitor common that can't be done from the contactor terminal that the...
  8. Common on the capacitor is nothing more than an...

    Common on the capacitor is nothing more than an extension or hub of the Line voltage that the run windings connect to.
  9. Also despite the terminology, 240v single power...

    Also despite the terminology, 240v single power has 2 distinct phases. I will never understand that, I just accepted it and moved on lol
  10. Common on the cap is common only for the cap. It...

    Common on the cap is common only for the cap. It is completely unrelated to the motor commons.
  11. That is baffling. Does the sound disappear...

    That is baffling. Does the sound disappear immediately after the condenser shuts off continue for a few seconds? It may be originating in the condenser or the air handler. Which thermostat do you...
  12. Just remember that there is no Common winding,...

    Just remember that there is no Common winding, only start and run. The run winding gets supplied with 120v and the common supplies the other line of 120. The start winding is fed voltage that goes...
  13. Replies
    7
    Views
    404

    Where do you live and what temperature are you...

    Where do you live and what temperature are you trying to maintain in the afternoon?
  14. Replies
    70
    Views
    5,285

    Holy sweet baby jesus... They really jammed 4...

    Holy sweet baby jesus... They really jammed 4 rotary comps into this thing! lol I don't know guy's I mean it was cooling, maybe these guy's are the smart ones. That thing is an engineering marvel IMO.
  15. Replies
    22
    Views
    956

    Just because the air handler says 3621 in the...

    Just because the air handler says 3621 in the number doesn't mean it's not a 3.5 ton system. The condenser is what determines the bulk of of the system capacity and yours is 3.5 tons.

    Since the...
  16. Replies
    22
    Views
    956

    The condenser is 3.5 tons and the air handler is...

    The condenser is 3.5 tons and the air handler is 3 tons nominal but is still a rated match for that condenser.
  17. Replies
    8
    Views
    352

    Do not use the SUPCO start kit it is a cheap 2...

    Do not use the SUPCO start kit it is a cheap 2 wire connection! Install on of the industry standard 3 wire connection kits. Use either the OEM part or a 5-2-1 Start kit. I would probably change the...
  18. I've used pancrete with success a few times....

    I've used pancrete with success a few times. Sealed up some pans on some old floor mount chilled water air handlers and sealed the base pans on some old rtu's that were just trying to get by for a...
  19. If the compressor valves were bad, neither of...

    If the compressor valves were bad, neither of them could pump. It's
    likely an electrical issue and not with the board.
  20. Thread: X13 motors

    by SoFlaDave
    Replies
    23
    Views
    9,691

    My experience is the same and it definitely...

    My experience is the same and it definitely related to moisture as I have had zero issues with the X13 motors in tranes Hyperion series AH and they are not exposed to moisture like standard air...
  21. That is the sad truth about our industry and I...

    That is the sad truth about our industry and I can see the difference in quality after being in the field for just 14 yrs. I had a 30+ yr old GE/ Trane system that the compressor had been miswired...
  22. I apologize if this had been brought up already...

    I apologize if this had been brought up already but there are a few things to address.
    1: Ductless mini splits run the indoor fan constantly to keep air moving over the temperature sensor and they...
  23. Yeah, its against building code to seal the eaves...

    Yeah, its against building code to seal the eaves at least in my area.
  24. The ducts sweat because the dewpoint raises as...

    The ducts sweat because the dewpoint raises as the temp drops and humidity goes up. We get that all the time down here on houses with spray foamed attics. The temperature in the attic stays in the...
  25. Replies
    59
    Views
    2,904

    Yes eventually it would freeze up if it ran long...

    Yes eventually it would freeze up if it ran long enough.