  1. Replies
    3
    Views
    1,597

    ross custerd macnine3

    can any one give me ant information on these machines do they have a solenoid valve to pump down the system
  2. Replies
    4
    Views
    480

    thank im in the trades where eles can i find more...

    thank im in the trades where eles can i find more info on heat pumps thanks again
  3. Replies
    4
    Views
    480

    carrier heat pump problems

    this is the second of for heat pumps in this resturant first i would like to thank every one with the first problem the reversing valve shutlle was stuck Now for the second heat pump little or...
  4. Replies
    8
    Views
    2,030

    this unit it hard piped and i cracked the...

    this unit it hard piped and i cracked the discharge side of the coil and had good water flow.I also had the building engineer turn on an extra condeser pump for the building since this is a closed...
  5. Replies
    8
    Views
    2,030

    well the reason i think its the reversing valve...

    well the reason i think its the reversing valve im getting a hissing sound ive got a high suction pressure and the suction line is hot
  6. Replies
    8
    Views
    2,030

    carrier heat pump problems

    im having a problem with a carrier heat pump in the cooling mode the reversing valve is leaking by the unit is water cooled it was on a no cool call i reached through the condenser and it was hotter...
  7. Replies
    11
    Views
    966

    thanks

    how do i become a pro member??
  8. Replies
    11
    Views
    966

    now its working the hissing sound went a way the...

    now its working the hissing sound went a way the pressures dropped and the house is cool 71deg but i cant explain the problem the out side temp is80 deg when the customer first tried to start the...
  9. Replies
    11
    Views
    966

    i forgot to mention this is an R-22 unit

    i forgot to mention this is an R-22 unit
  10. Replies
    11
    Views
    966

    copeland scrollcompressor

    does any one know if copeland has a recall or why if your lucky to get a couple of years out of it.Went tothe start my a/c today the compressor would start then shut down put my gages on the suction...
  11. Replies
    4
    Views
    1,475

    thank you

    thank you
  12. Thread: Hiring season?

    by 83davem
    Replies
    10
    Views
    1,284

    Good luck with the new job :cheers:

    Good luck with the new job :cheers:
  13. Replies
    4
    Views
    1,475

    no but close corner bakery thanks i didnt even...

    no but close corner bakery thanks i didnt even think about that switch buy any chance do you know where i can get a service manual for this oven
  14. Replies
    4
    Views
    1,475

    baxter 300g oven rotisary wont stop

    im trying to find a schmatic for this oven and some advice the rotisary will not stop when the doors open ive tried to adjust the door switches i have replaced the relay the old won was welded...
  15. Thread: Hiring season?

    by 83davem
    Replies
    10
    Views
    1,284

    give it time once the weather get warm the calls...

    give it time once the weather get warm the calls will come
  16. Replies
    7
    Views
    1,371

    freeze stat

    here is the model lga102hs1y serial number 5601e09240 Thanks for the infomation and your help:cheers:
  17. Replies
    7
    Views
    1,371

    freeze stat problems

    need help with a freeze stat on a lennox l series rtu .im able to clear the fault and get the unit running but in a couple day ill get the 33 fault again my pressures are on the money