  1. i work mostly on r22. recently just started using...

    i work mostly on r22. recently just started using a heat gun on the compressor to boil out water and refrigerant. i agree the micron gauge should come after the n2. using the n2 to find leaks. are we...
  2. Replies
    33
    Views
    1,230

    i had a split that kept tripping the fuse. never...

    i had a split that kept tripping the fuse. never caught it in the act, disconnected tried continuity and ohms. never got anything the indicated a short, though i suspected short between ahu and...
  3. Replies
    43
    Views
    1,170

    my freshman year at a university my philosophy...

    my freshman year at a university my philosophy professor asked, "Is there a difference between men and women." all the babes in the room said no, most of the men said yes. the professor started this...
  4. we have the unit in our shop, waiting for her...

    we have the unit in our shop, waiting for her chance to be dissected. i still sense a blockage. thanks for the pointer.
  5. Replies
    15
    Views
    659

    I was taught at least six inches from king valve...

    I was taught at least six inches from king valve on suction line for sh.
  6. no filter drier on the equipment.

    no filter drier on the equipment.
  7. yeah i replaced a condenser fan already. ours are...

    yeah i replaced a condenser fan already. ours are in the basement at grade. so i drop it into a cart and go to work. the 10 inch lift to get her back in is never easy. sounds dirty. can the TXV be...
  8. this is one of our older pieces of equipment, and...

    this is one of our older pieces of equipment, and has a txv. we have plenty of newer bryants all with caps. either way i prefer split systems. this through the wall crap is for the birds.
  9. yes old and cramped inside. i did notice a little...

    yes old and cramped inside. i did notice a little breathing action on my low side. the tech b4 me replaced the compressor and it seems to be running swell, didnt get my amp meter around her yet.
  10. this model does have a txv. model # is...

    this model does have a txv. model # is 5pwc242a-5a.
    jtrammel i know the LL, is liquid line. not sure what you mean by MD.
  11. Could possibly a blocked TXV be causing my...

    Could possibly a blocked TXV be causing my trouble? would a over night vacuum clear a blockage or that sort.
  12. Armstong "MagicPak", Low Side Vacuum.

    I have to look after a bunch of these through the wall heatpump systems. today i recovered the refrigerant. thought their was a leak or blockage. because my low side gauge would pull into a vacuum....
  13. Changing location of high pressure control.

    hello,
    thanks ahead for any help. i have a rare bad high pressure switch. tested it, had no continuity, normally closed. i know this is very rare. well my question is. im not really in the position...
  14. use only mc and b tanks but with all the high...

    use only mc and b tanks but with all the high praise of oxy/ace i think i might have a serious decision to make.
  15. Replies
    52
    Views
    4,419

    working for property management firm. van stays...

    working for property management firm. van stays at the shop, gotta unload my tools everyday. also unload/load refrigerant everyday. when on call i get paid mileage from home to work and back again....
  16. Replies
    1
    Views
    303

    hello from coal country pa

    hello all. looking to become an active member of the community. i will start with a little bio. graduated high school and like many 18 yrs today i was very unsure of my future. and like many youths i...